Rosemount™ 2088 Gage and Absolute Pressure Transmitter 316L SST, Alloy C-276 NSF, NACE®, hazardous location

 

 

Specifications

 

WarrantyUp to 1-year limited warranty
RangedownUp to 50:1
Communication Protocol4-20 mA HART®, 1-5 V Low Power HART®
Measurement RangeUp to 4,000 psig (275,8 bar) Gage, Up to 4,000 psia (275,8 bar) Absolute
Process Wetted Material316L SST, Alloy C-276
DiagnosticsBasic Diagnostics
Certifications/ApprovalsNSF, NACE®, hazardous location, see full specs for complete list of certifications

 

 

 

 

Model 2088 Low Power

 

Current procedures for installing, configuring, and maintaining the Model 2088 Smart Low-Power transmitter are identical to the Model 2088 Smart transmitter with 4-20 mA output, see manual 00809-0100-4690.

 

The current wiring diagram and Model 275 HART fast-key sequences for the Model 2088 Low Power option are shown below.

 

 

Mount the transmitter

 

The following are approximate weights of each transmitter:

 

 Rosemount 2088 2.44 lb (1,11 kg)

 Rosemount 2090F 2.74 lb (1.24 kg)

 Rosemount 2090P 2.96 lb (1.34 kg).

 

In many cases its compact size and light weight makes it possible to mount directly to the respective apparatus without using an additional mounting bracket. When this is not desirable, mount directly to a wall, panel, or two-inch pipe using the optional mounting bracket

 

 

Electronics housing clearance

 

Mount the transmitter so the terminal side is accessible. Clearance of 0.75-in. (19 mm) is required for cover removal. Use a conduit plug in the unused conduit opening. Three inches of clearance is required for cover removal if a meter is installed.

 

 

Environmental seal for housing

 

Thread sealing (PTFE) tape or paste on male threads of conduit is required to provide a water/dust tight conduit seal and meets requirements of NEMA® Type 4X, IP66, and IP68. Consult factory if other Ingress Protection ratings are required.

 

For M20 threads, install conduit plugs to full thread engagement or until mechanical resistance is met.

 

 

Mounting brackets 

 

Rosemount 2088, 2090F, or 2090P transmitters may be panel-mounted or pipe-mounted via an optional mounting bracket (option code B4). See Figure 3-1 on page 32 and for dimensional and mounting configuration information.

 

 

Configuring transmitter security

 

There are four security methods with the Rosemount 2088, 2090F, and 2090P transmitters. 

 

 Security switch

 HART® Lock

 Configuration Buttons lock

 LOI password

 

 

 

 

 

 

 

 

 


Email : keji2203@163.com

 

 

 

 

 

 

 

 

 

 

 

Hot Products

NEW SCHNEIDER ELECTRIC Power Supply Module HI SPEED COUNTER 140EHC10500 Specifications Manufacturer: ...
Ovation Module Sequence Of Events 48VDC On-board 1C31233G04 Digital I O Module Westinghouse Item ...
SIL 2/3 certified to IEC 61508 by an independent 3rd party Rosemount™ 2051 Differential Pressure ...
Schneider Power Supply Module 140CRP93100 Modicon Quantum Rio Head S908 1-Channel This Schneider ...
Rosemount™ 2088 Gage and Absolute Pressure Transmitter 316L SST, Alloy C-276 NSF, NACE®, hazardous ...
Rosemount™ 3051HT Hygienic Pressure Transmitter 4-20 mA HART®, FOUNDATION™ Fieldbus Up to 150 psia ...