Specification |
Accuracy class | | OIML R60 C3 |
Output sensitivity ( = FS ) | mV/V | 2.0 ± 0.002 |
Maximum capacity ( Emax ) | t | 10/20/25 | 30/40LE/40/50 |
Maximum number of load cell intervals ( nLC ) | | 3000 |
Ratio of minimum LC verification interval Y = Emax / vmin | | 15000 | 7500 |
Combined error | %FS | ± 0.023 |
Minimum dead load | klb | 0 |
Safe overload | %FS | 150 |
Ultimate overload | %FS | 300 |
Zero balance | %FS | ± 1.5 |
Excitation, recommended voltage | V | 5 ~ 12( DC ) |
Excitation maximum | V | 18( DC ) |
Input resistance | Ω | 700 ± 7 |
Output resistance | Ω | 700 ± 7 |
Insulation resistance | MΩ | ≥ 5000 ( 50VDC ) |
Compensated temperature | ℃ | -10 ~ +40 |
Operating temperature | ℃ | -35 ~ +65 |
Storage temperature | ℃ | -40 ~ +70 |
Element material | | Nickel plated alloy steel |
Ingress protection (according to EN 60529) | | IP68 |
ATEX classification (optional) | | II1G Ex ia IIC T4 | II1D Ex iaD 20 T73℃ | II3G Ex nL IIC T4 |