Home Companies Melan Measurement & Control Instruments (Shanghai) Co.,Ltd.

China Factory Mag Flow Meter 100mm (4 Inch) ANSI Flange Connection

Melan Measurement & Control Instruments (Shanghai) Co.,Ltd.
Active Member

Contact Us

[China] country

Address: No.21, Lane 697, Guangfulin Road, Songjiang District, Shanghai, China

Contact name:Nancy Zhao

Inquir Now

Melan Measurement & Control Instruments (Shanghai) Co.,Ltd.

China Factory Mag Flow Meter 100mm (4 Inch) ANSI Flange Connection

Country/Region china
City & Province shanghai shanghai
Categories Flanges
InquireNow

Product Details

                                          China Factory Mag Flow Meter 100mm (4 Inch) ANSI Flange Connection

 

1. Introduction

MLF electromagnetic flow meter, composed of sensor and converter, works based on Faraday’s law of electromagnetic induction law. It is used to measure electrical conductivity of liquid or solid. Generally, the electrical conductivity should be over 5υS/cm(electrical conductivity of tap water, raw water is about 100~500υS/cm). It can also be used to measure various media like acid, alkali, saline solution, paper pulp or pulp and so on. But these media can’t contain a lot of magnetic materials and bubbles.

MLF electromagnetic flow meter is a kind of instrument which is used for measuring the flow conductivity liquid. The meter is widely used in flow measuring of Metallurgy, Chemical Industry, Paper Industry,Environmental Protection, Oil Industry, Textile Industry, Food Industry and City Administration, Water Works,etc.

 

2. Features
The MLF electromagnetic flow meter is for explosive proof design.
It has the function of low conductivity measurement.
It has Chinese, English, Korean, Polish, Turkish, French and Portuguese languages languages for option to satisfy different customers’ requirements.
It has the function of self-adjustment and self-checking.
A variety of outputs are optional:Hart, RS485, Profibus, 4-20mA, Frequency, Pulse.

 

 

3. Specification

MLF TypeDivided TypeIntegrated TypeExplosive Proof Integrated TypeBattery Powered TypeHeat Energy Type
Accuracy±0.2% or ±0.5%
Pipeline DiameterDN10-DN2000DN10-DN600DN25-DN2000
FlangeGB, ANSI, JIS, BS, Others
PressureDN10-DN600 1.0 1.6 2.5 4.0MPa
DN700-DN2000 0.6 1.0 1.6MPa
Liner MaterialCR, PTFE, PU, Hard Rubber, PFA, FEP(F46)
Conductivity≥5µs/cm(Please contact us if it is less than 5µs/cm)
Electrode316L SS, Hb, Ta, Ti, Hc, Tungsten Carbide, Others
Protection ClassIP65, IP66, IP67, IP68
Medium Temperature-25~180
(Please refer to liner material)
-25~80(Please refer to liner material)-25~180
(Please refer to liner material)
Ambient Temperature for Accuracy Influence<±0.1%/10 or <±0.25%/10 at the ambient temperature of -25~60
Repetability≤±0.1% or ±0.25%
Analog Output Error≤±0.02mA
Velocity0.3~10m/s
Electrical connectionM20x1.5 Seal Cartridge, GB1/2, NPT1/2
Output4-20mA, Pulse, RS485, Hart, Profibus

 

4. Selection of Liner Material

Liner MaterialMain PerformanceApplication
PTFE

1 It has the most stable chemical properties in plastics, resistant to boiling hydrogen chloride and sulfuric acid, nitric acid, aqua regia, strong alkali and various organic solvents, but not resistant to chlorine trifluoride, high temperature nitrogen trifluoride, liquid fluorine, and liquid oxygen And ozone corrosion.

2 Low wear resistance.

3 Low negative pressure resistance.

1. -25~140℃

2. Strong corrosion medium, like strong acid and alkali

3. Healthcare medium

CROil proof, solvent resistance, oxidatite resistance and the resistance to the erosion of common medium like acid, alkali, salt, etc.

1. <80℃

2. Be able to measure sewage and mud

PU

1. Very good abrasive resistance, flexibility.

2. Low acid and alkali resistance.

1. <65℃

2. Neutral strong abrasion resistance medium

Hard Rubber

1 Resistance to room temperature, hydrochloric acid, acetic acid, oxalic acid, ammonia, phosphoric acid and 50% sulfuric acid, sodium hydroxide and potassium hydroxide

2 Avoid strong oxidants

1. <80℃

2. General acid, alkali, salt solution

PFA

1. Can be used for most corrosive medium like acides, alkalis, and strong oxidant.

2. High material strength, resistance to aging, better than PTFE, EFP in high temperature 

3. Injection molding for higher negative pressure

1. 40~180℃

2. Strong corrosion medium, like strong acid and alkali

3. Healthcare mdium

FEP(F46)

1. Hydrophobicity and non-viscous

2. Corrosion resistance is inferior to PFA

3. Negative pressure

1. 40~180℃

2. Strong corrosion medium, like strong acid and alkali

3. Healthcare mdium

 

 

5. Dimensional Sketches

a. Dimension of Converter

                                                                      Divided Type

 

 

                                                                      Integrated Type

 

                                                                  Battery Powered Type

 

 

b. Dimension of Sensor

 

 

Pipeline DiameterDimension
LWH
1516095130
20160105137
25160115150
32160135160
40200145175
50200160185
65200180205
80200195215
100250215235
125250245275
150300280300
200350335355
250400400405
300500455460
350500515520
400600575580
450600635630
500600710685
600600835795
700700905910
80080010201030
90090011201120
1000100012451250
1200120014651470

 

6. Configuration

MLF Series Electromagnetic Flow Meter Configuration
ModelMLF
Sensor InstallationSFlange Type Sensor
CInsertion Type Sensor
OOthers
Pipeline Diameter1010mm
1515mm
2020mm
...... 
20002000mm
Electrode InstallationFStandard Fixed Type
Electrode MaterialA316L SS
BHb
CTa
DTi
EHc
FTungsten Carbide
GOthers
Liner MaterialRRubber
PPTFE
OOthers
Pipe MaterialB304 SS (Standard)
C316 SS
Flange TypeGGB (Standard)
AANSI
JJIS
BBS
OOthers 
Flange MaterialA304 SS
B316 SS
C#20 Carbon Steel (Standard)
Cover MaterialD304 SS
E316 SS
FCarbon Steel+ Epoxy Metallic Paint (Standard)
Matching Flange0Without Matching Flange (Standard)
1With Matching Flange
Ground Ring0Without Ground Ring (Standard)
1With Ground Ring
Rated Pressure101.0MPa
161.6MPa
252.5MPa 
404.0MPa
Working TemperatureE≤60℃
H≤180℃(Divided Type)
TypeIIntegrated Type
DDivided Type
OutputPPulse
A4-20mA
GRS485
HHart
QOthers
Power Supply0220VAC
124VDC
2Battery-powered
Protection Class0IP65 (Integrated/Divided Type)
1IP67 (Divided Type)
2IP68 (Divided Type)
Other FeaturesRHeat Energy Function
PWith PT1000
BWithout PT1000
Explosion Proof0None
EXExplosive Proof

 

 

7. Advantages & Disadvantages

There are numerous benefits to using electromagnetic flowmeters to perform fluid flow measurements. They are generally non-invasive and have no moving parts, reducing the risk of breakdowns and the frequency of repairs. A decrease in flowmeter pressure is also usually no greater than that of an equivalent pipe length, reducing the piping costs. Some of the other major advantages provided by magnetic flowmeters include:

  • Power usage is relatively low, with electrical power requirements as low as 15 watts for some models.
  • They are mechanically obstructionless and can be equipped with abrasion-resistant liners, making them effective for measuring slurries and other erosive fluids.
  • They are capable of dealing with most kinds of acids and bases, as well as water and water-based solutions, due to lining materials that are both insulators and have corrosion resistance.
  • Relatively small amounts of electrode metals are needed for magnetic flowmeters.
  • They can measure both very low flows and very high volume flow rates, with a minimum diameter of roughly 0.125 inches and a maximum volume of up to 10 cubic feet.
  • They can usually measure multidirectional flow, either upstream or downstream.

Despite these advantages, magnetic flowmeters also present certain difficulties for flow rate measurement. These flowmeters are only effective on conductive fluids, and materials such as unmixed hydrocarbons and gases cannot be measured. However, magnetic materials themselves may also present problems, as hydrodynamic effects can alter the normal flow pattern and disturb the velocity rate enough to interfere with operations. Depending on their size and capacity, magnetic flowmeters can be relatively heavy, and those with higher corrosion and abrasion resistance can be expensive.

 

Hot Products

Magnetic Flow Meter For Pulp And Paper Industry Slurry Application 1. Introduction MLF electromagnet...
Mag Flow Meter With Carbon Steel DN800 Rubber Liner PN10 Flanges 1. Introduction MLF electromagnetic ...
China High Quality Mag Flow Meter Electromagnetic Water Flow Meter​ 1. Introduction The MLF ...
China Food Beverage Electromagnetic Flow Meter / Sanitary Magnetic Flowmeter 1. Introduction MLF ...
China Factory Mag Flow Meter 100mm (4 Inch) ANSI Flange Connection 1. Introduction MLF electromagnet...
Wall Mounted Ultrasonic Flowmeter DN50mm DN6000mm Liquid Flow Meter Modbus RS485 I. Introduction ML...