Home Companies Melan Measurement & Control Instruments (Shanghai) Co.,Ltd.

Integrated Type EMF Flange Electromagnetic Flow Meter

Melan Measurement & Control Instruments (Shanghai) Co.,Ltd.
Active Member

Contact Us

[China] country

Address: No.21, Lane 697, Guangfulin Road, Songjiang District, Shanghai, China

Contact name:Nancy Zhao

Inquir Now

Melan Measurement & Control Instruments (Shanghai) Co.,Ltd.

Integrated Type EMF Flange Electromagnetic Flow Meter

Country/Region china
City & Province shanghai shanghai
Categories Other Electric Power Tools
InquireNow

Product Details

                                                    EMF Flange Integrated Type Electromagnetic Flow Meters

 

1. Introduction

MLF electromagnetic Flowmeter works according to Faraday's law of electromagnetic induction and is composed of sensors and converters. Used to measure the electrical conductivity of liquids or solids. In general, its electrical conductivity should be greater than 5 μ S / cm (the electrical conductivity of tap water and raw water is about 100 ~ 500 μS / cm), can also be used to measure various media such as acid, alkali, salt water, pulp or pulp. But these media cannot contain large amounts of magnetic materials and bubbles.

MLF electromagnetic Flowmeter is an instrument for measuring liquid fluidity. It is widely used in flow measurement in metallurgy, chemical industry, paper making, environmental protection, petroleum, textile, food, urban management, waterworks and other industries.

 

2.Working Principle

The principle of the sensor is based on Faraday’s law of electromagnetic induction.

It is installed a pair of detection electrodes on the pipe wall,where the measurement pipe axis

and magnetic field lines are vertical. When the conductive liquid cuts magnetic field lines and

produces induced electromagnetic force.Which can be measured by the two electrodes on the

meter pipe.The result can be calculated by formula: Induced electromotive force,(flow signal)

E=KBDV

E——Induced electromotive force,V;

K——meter constant;

B——Magnetic flux density,T;

D——Internal diameter of measuring pipe,m;

V——Average velocity of pipe section,m/s.

1MLF Series Electromagnetic Flow Meter

Assume the volume of liquid as qv(m3/s),qv=πD2V/4),so in the formula E=(4kB/πD)qv=kqv,

K is meter constant,K=4kB/πD.

Actually, the electromagnetic flow meter consists of two parts, transmitter and sensor, the

measuring electrodes inspect the electromotive force, and transmit to the converter, the

converter provides excitation current.

E is usually called a flow signal, after processing the flow signal by converter, output 4~20 mA/

pulse(or frequency) signal which is proportional to the flow rate, then the flow rate recording,

adjusting can be achieved.

 

3. Features

MLF electromagnetic Flowmeter is explosion-proof design.

function of low conductivity measurement.

There are 9 language options to meet the needs of different customers.

Have self-regulation function and self-examination.

different outputs are optional: hart, RS485 Profibus ,4-20 mA, frequency, pulse.

 

4. Specification

MLF TypeDivided TypeIntegrated TypeExplosive Proof Integrated TypeBattery Powered TypeHeat Energy Type
Accuracy±0.2% or ±0.5%
Pipeline DiameterDN10-DN2000DN10-DN600DN25-DN2000
FlangeGB, ANSI, JIS, BS, Others
PressureDN10-DN600 1.0 1.6 2.5 4.0MPa
DN700-DN2000 0.6 1.0 1.6MPa
Liner MaterialCR, PTFE, PU, Hard Rubber, PFA, FEP(F46)
Conductivity≥5µs/cm(Please contact us if it is less than 5µs/cm)
Electrode316L SS, Hb, Ta, Ti, Hc, Tungsten Carbide, Others
Protection ClassIP65, IP66, IP67, IP68
Medium Temperature-25~180
(Please refer to liner material)
-25~80(Please refer to liner material)-25~180
(Please refer to liner material)
Ambient Temperature for Accuracy Influence<±0.1%/10 or <±0.25%/10 at the ambient temperature of -25~60
Repetability≤±0.1% or ±0.25%
Analog Output Error≤±0.02mA
Velocity0.3~10m/s
Electrical connectionM20x1.5 Seal Cartridge, GB1/2, NPT1/2
Output4-20mA, Pulse, RS485, Hart, Profibus

 

5. Selection of Liner Material

Liner MaterialMain PerformanceApplication
PTFE

1 It has the most stable chemical properties in plastics, resistant to boiling hydrogen chloride and sulfuric acid, nitric acid, aqua regia, strong alkali and various organic solvents, but not resistant to chlorine trifluoride, high temperature nitrogen trifluoride, liquid fluorine, and liquid oxygen And ozone corrosion.

2 Low wear resistance.

3 Low negative pressure resistance.

1. -25~140℃

2. Strong corrosion medium, like strong acid and alkali

3. Healthcare medium

CROil proof, solvent resistance, oxidatite resistance and the resistance to the erosion of common medium like acid, alkali, salt, etc.

1. <80℃

2. Be able to measure sewage and mud

PU

1. Very good abrasive resistance, flexibility.

2. Low acid and alkali resistance.

1. <65℃

2. Neutral strong abrasion resistance medium

Hard Rubber

1 Room temperature, hydrochloric acid, acetic acid, oxalic acid, ammonia, phosphoric acid and 50% sulfuric acid, sodium hydroxide, potassium hydroxide

2  Avoid strong oxidizing agents

1. <80℃

2. General acid, alkali, salt solution

PFA

1. Can be used for most corrosive medium like acides, alkalis, and strong oxidant.

2. High material strength, resistance to aging, better than PTFE, EFP in high temperature 

3. Injection molding for higher negative pressure

1. 40~180℃

2. Strong corrosion medium, like strong acid and alkali

3. Healthcare mdium

FEP(F46)

1. Hydrophobicity and non-viscous

2. Corrosion resistance is inferior to PFA

3. Negative pressure

1. 40~180℃

2. Strong corrosion medium, like strong acid and alkali

3. Healthcare mdium

 

6. Selection of Electrode Materials

Electrode MaterialMain Performance
316LGood corrosion resistance of nitric acid, at room temperature <5% sulfuric acid, acetic acid, alkaline liquid, a certain pressure of sulphate, seawater, acetic acid and other corrosion, can be widely used in petrochemical urea, veline and so on.
Hb

Good resistance to all concentrations of hydrochloric acid below boiling point, as well as non-oxidizing acid, alkali, sulfuric acid, phosphoric acid, hydrofluoric acid and organic acid.

HcResistance to the corrosion of oxidizing acids like metric acid, mixed acid. The mixture of chromium acid and sulfuric acid, and salts of oxidative, like Fe3+, Q3+, and some other oxidants, like hypochlorite salt solution higher than normal tmperature and seawater.
TiCorrosion resistance of oxidizing acids, such as nitric acid and mixed acid. A mixture of chromic acid and sulfuric acid, oxides, such as Fe3+,Q3+, and other oxidants, such as a mixture of hypochlorite solution above normal temperature and seawater.
TaGood corrosion resistance similar to glass. Resistance to the corrosion of chemical medium(including hydrochloric acid and fumiing sulfuric acid), but can not be used for sodium hydromide fluid.
Pt-IrHave good corrosion resistance of all acid, and  can be resistance to the corrosion of alkali, all salt except aqua regia, ammonium slat and few other medium
Tungsten CarbideFor pulp and sewage, good resistance to solid particle interference.

 

 

7. Dimensional Sketches

a. Dimension of Converter

                                                                      Divided Type

 

 

                                                                      Integrated Type

 

                                                                  Battery Powered Type

 

 

b. Dimension of Sensor

 

 

Pipeline DiameterDimension
LWH
1516095130
20160105137
25160115150
32160135160
40200145175
50200160185
65200180205
80200195215
100250215235
125250245275
150300280300
200350335355
250400400405
300500455460
350500515520
400600575580
450600635630
500600710685
600600835795
700700905910
80080010201030
90090011201120
1000100012451250
1200120014651470

 

Hot Products

Electromagnetic Flow Meter for Water Flow Rate Measurement 1. Introduction The MLF electromagnetic ...
High Quality Cheap Water Magnetic Flowmeter 1. Introduction 1. The MLF electromagnetic flowmeter ...
Cement Grout Concrete Magnetic Flow Meter 1. Introduction The MLF electromagnetic flow meter is ...
Best Technology Guide to Magnetic Flow Meters 1. Introduction 1. MLF electromagnetic flowmeter works ...
EMF Flange Integrated Type Electromagnetic Flow Meters 1. Introduction MLF electromagnetic Flowmeter ...
DN200 Electromagnetic Water Flow Meter Type Price 1. Introduction The MLF electromagnetic flowmeter ...