                                     Electromagnetic Flow Meter 1 1/2 Inch(40mm) Heavy Duty & Good Quality

 

1. Introduction

MLF electromagnetic flowmeter works according to Faraday's law of electromagnetic induction, and is composed of sensors and converters. Used to measure the conductivity of liquid or solid. In general, its conductivity should be greater than 5μs/cm (tap water and raw water conductivity is about 100 ~ 500μs/cm), and it can also be used to measure acid, alkali, brine, pulp or pulp and other media. However, these media cannot contain a large amount of magnetic substances and bubbles.

MLF electromagnetic flowmeter is an instrument for measuring liquid fluidity. Widely used in metallurgy, chemical industry, paper making, environmental protection, petroleum, textile, food, urban management, water plant and other industries.

 

2.Working Principle

The principle of the sensor is based on Faraday’s law of electromagnetic induction.

It is installed a pair of detection electrodes on the pipe wall,where the measurement pipe axis and magnetic field lines are vertical. When the conductive liquid cuts magnetic field lines and produces induced electromagnetic force.Which can be measured by the two electrodes on the

meter pipe.The result can be calculated by formula: Induced electromotive force,(flow signal) E=KBDV

E——Induced electromotive force,V;

K——meter constant;

B——Magnetic flux density,T;

D——Internal diameter of measuring pipe,m;

V——Average velocity of pipe section,m/s.

MLF Series Electromagnetic Flow Meter

Assume the volume of liquid as qv(m3/s),qv=πD2V/4),so in the formula E=(4kB/πD)qv=kqv,

K is meter constant,K=4kB/πD.

Actually, the electromagnetic flow meter consists of two parts, transmitter and sensor, the measuring electrodes inspect the electromotive force, and transmit to the converter, the converter provides excitation current.

E is usually called a flow signal, after processing the flow signal by converter, output 4~20 mA/pulse(or frequency) signal which is proportional to the flow rate, then the flow rate recording,adjusting can be achieved.

 

3. Features

MLF electromagnetic flowmeter is explosion-proof design.

Low conductivity measurement function.

There are nine languages options to meet the needs of different customers.

It has self-regulation function and self-test.

Different outputs are optional: Hart, RS485, Profibus, 4-20mA, frequency, pulse.

 

4. Specification

MLF TypeDivided TypeIntegrated TypeExplosive Proof Integrated TypeBattery Powered TypeHeat Energy Type
Accuracy±0.2% or ±0.5%
Pipeline DiameterDN10-DN2000DN10-DN600DN25-DN2000
FlangeGB, ANSI, JIS, BS, Others
PressureDN10-DN600 1.0 1.6 2.5 4.0MPa
DN700-DN2000 0.6 1.0 1.6MPa
Liner MaterialCR, PTFE, PU, Hard Rubber, PFA, FEP(F46)
Conductivity≥5µs/cm(Please contact us if it is less than 5µs/cm)
Electrode316L SS, Hb, Ta, Ti, Hc, Tungsten Carbide, Others
Protection ClassIP65, IP66, IP67, IP68
Medium Temperature-25~180
(Please refer to liner material)
-25~80(Please refer to liner material)-25~180
(Please refer to liner material)
Ambient Temperature for Accuracy Influence<±0.1%/10 or <±0.25%/10 at the ambient temperature of -25~60
Repetability≤±0.1% or ±0.25%
Analog Output Error≤±0.02mA
Velocity0.3~10m/s
Electrical connectionM20x1.5 Seal Cartridge, GB1/2, NPT1/2
Output4-20mA, Pulse, RS485, Hart, Profibus

 

5. Selection of Electrode Materials

Electrode MaterialMain Performance
316L

Good corrosion resistance to nitric acid, less than 5% corrosion of sulfuric acid, acetic acid, alkaline liquid, sulfite, seawater and acetic acid under certain pressure at room temperature, and can be widely used in petrochemical urea, vinylon and so on

Hb

Good resistance to all concentrations below boiling point of hydrochloric acid, but also resistant to non-oxidizing acids, alkalis, sulphuric acid, phosphoric acid, hydrofluoric acid, organic acid corrosion.

Hc

Resistant to the corrosion of oxidizing acid, such as nitric acid and mixed acid. The mixture of chromic acid and sulfuric acid, oxidized salts, such as Fe3+, Q3+, and other oxidants, such as the mixture of hypochlorite solution and seawater at higher than normal temperature.

Ti

It is resistant to corrosion of sea water, various chlorides, hypochlorite, oxidizing acid (including fuming nitric acid), organic acid or alkali, but not pure reducing acid (such as sulfuric acid, hydrochloric acid).

However, if the acid contains oxidants (such as nitric acid, Fe3+, Q3 +), the corrosion resistance will be reduced.

TaGood corrosion resistance similar to glass. Resistance to the corrosion of chemical medium(including hydrochloric acid and fumiing sulfuric acid), but can not be used for sodium hydromide fluid.
Pt-IrHave good corrosion resistance of all acid, and can be resistance to the corrosion of alkali, all salt except aqua regia, ammonium slat and few other medium
Tungsten CarbideFor pulp and sewage, good resistance to solid particle interference.

 

 

6. Instrument Testing & Maintenance

 

Electromagnetic Flowmeter has self-diagnosis function. In addition to power and hardware circuit failures, the system also alarm other faults in general use. The information is prompted in the lower right corner of the screen.

 

1. Maintenance and repair

a) sensor installation site should meet the requirements of Section 4, please keep the shell clean;

b) transmitters shall be placed in a clean, ventilated, dry place;

c) need to be checked every two years, for high-precision users, the instrument needs to be submitted for review.

 

2. Transport and storage

a) instruments must be packed before transportation, loading and unloading should be carefully light.

b) storage place must be dry, ventilated, avoid corrosive gas erosion, environmental temperature should not be too low or too high;

c) storage time should not exceed three years.

 

3. Open-box inspection

a) packing must not be opened with a heavy hammer, be careful not to damage the instrument

b) carefully check the contents according to the packing list.

 

 

7. Product Photos

 

 

Hot Products

Digital Refrigerant Water Electromagnetic Flow Meter with Analog Output 1. Introduction MLF ...
ANSI150 Pipe Full Bore Electromagnetic Flow Meter 1. Introduction MLF electromagnetic Flowmeter ...
Flanged End Electromagnetic Flow Meter Remote Type 1. Introduction MLF electromagnetic flowmeter is ...
Electromagnetic Flow Meter Manufacturer / Seawater Flow Meter​ 1. Introduction MLF electromagnetic ...
Electromagnetic Flow Meter 1 1/2 Inch(40mm) Heavy Duty & Good Quality 1. Introduction MLF electromag...
DN150 Mag Flow Meter with PTFE Liner and ANSI150# Flanges 1. Introduction The MLF electromagnetic ...