Home Companies Melan Measurement & Control Instruments (Shanghai) Co.,Ltd.

Clamp Type Electromagnetic Flow Meter Stainless Steel with 220VAC / 24VDC / Battery Powered

Melan Measurement & Control Instruments (Shanghai) Co.,Ltd.
Active Member

Contact Us

[China] country

Address: No.21, Lane 697, Guangfulin Road, Songjiang District, Shanghai, China

Contact name:Nancy Zhao

Inquir Now

Melan Measurement & Control Instruments (Shanghai) Co.,Ltd.

Clamp Type Electromagnetic Flow Meter Stainless Steel with 220VAC / 24VDC / Battery Powered

Country/Region china
City & Province shanghai shanghai
Categories Camera Chargers
InquireNow

Product Details

                              Clamp Type Electromagnetic Flow Meter Stainless Steel with 220VAC / 24VDC / Battery Powered

 

1. Introduction

MLF electromagnetic flow meter, composed of sensor and converter, works based on Faraday’s law of electromagnetic induction law. It is used to measure electrical conductivity of liquid or solid. Generally, the electrical conductivity should be over 5υS/cm(electrical conductivity of tap water, raw water is about 100~500υS/cm),It can also be used to measure various media like acid, alkali, saline solution, paper pulp or pulp and so on. But these media can’t contain a lot of magnetic materials and bubbles.

MLF electromagnetic flow meter is a kind of instrument which is used for measuring the flow conductivity liquid. The meter is widely used in flow measuring of Metallurgy, Chemical Industry, Paper Industry,Environmental Protection, Oil Industry, Textile Industry, Food Industry and City Administration, Water Works,etc.

 

2. Quick Details

1). It is high resistance, fast response design can make undistorted collection of weak signal and fast response to the flow changes. Its range rate can reach 100:1.

2). It has the function of low conductivity measurement.

3). It has the consistency of converter’s interchange, which can avoid input parameters repeatedly.

4). Wide range of power supply mode is available (DC: 18V-36V/AC: 85V-265V).

5). It is the first domestic company that adopts the function of saving settings before delivery,which can avoid the loss of the parameters.

6). It adopts the international leading excitation technology, which circuit is simple, stable,and reliable.

7). It has the function of infrared remote control and button operation so as to make the operation more convenient.

8). It provides the function of zero correction of sensor and automatic zero adjustment.

9). It has Chinese, English, Korean, Polish, Turkish, French and Portuguese languages for option to satisfy different customers’ requirements.

 

 

3. Specification

MLF TypeDivided TypeIntegrated TypeExplosive Proof Integrated TypeBattery Powered TypeHeat Energy Type
Accuracy±0.2% or ±0.5%
Pipeline DiameterDN10-DN2000DN10-DN600DN25-DN2000
FlangeGB, ANSI, JIS, BS, Others
PressureDN10-DN600 1.0 1.6 2.5 4.0MPa
DN700-DN2000 0.6 1.0 1.6MPa
Liner MaterialCR, PTFE, PU, Hard Rubber, PFA, FEP(F46)
Conductivity≥5µs/cm(Please contact us if it is less than 5µs/cm)
Electrode316L SS, Hb, Ta, Ti, Hc, Tungsten Carbide, Others
Protection ClassIP65, IP66, IP67, IP68
Medium Temperature-25~180
(Please refer to liner material)
-25~80(Please refer to liner material)-25~180
(Please refer to liner material)
Ambient Temperature for Accuracy Influence<±0.1%/10 or <±0.25%/10 at the ambient temperature of -25~60
Repetability≤±0.1% or ±0.25%
Analog Output Error≤±0.02mA
Velocity0.3~10m/s
Electrical connectionM20x1.5 Seal Cartridge, GB1/2, NPT1/2
Output4-20mA, Pulse, RS485, Hart, Profibus

 

4. Selection of Liner Material

Liner MaterialMain PerformanceApplication
PTFE

1. Have the most stable chemical properties in plastic and resistance to boiling hydrochlor and sulfuric acid, nitric acid aqua regia, strong alkali, and all kinds of organic solvents, but can not resist the corrosion of chlorine trifluoride, high temperature nitrogen trifluoride, liquid fluorine, liquid oxygen and ozone.

2. Low abrasion resistance.

3. Low negative pressure resistance

1. -25~140℃

2. Strong corrosion medium, like strong acid and alkali

3. Healthcare medium

CROil proof, solvent resistance, oxidatite resistance and the resistance to the erosion of common medium like acid, alkali, salt, etc.

1. <80℃

2. Be able to measure sewage and mud

PU

1. Very good abrasive resistance, flexibility.

2. Low acid and alkali resistance.

1. <65℃

2. Neutral strong abrasion resistance medium

Hard Rubber

1. Good resistance to room temperature, hydrochloric acid, acetic acid, oxalic acid, ammonia, phosphoric acid and 50% sulfuric acid, sodium hydroxide, potassium hydroxide

2. Avoid strong oxidants

1. <80℃

2. General acid, alkali, salt solution

PFA

1. Can be used for most corrosive medium like acides, alkalis, and strong oxidant.

2. High material strength, resistance to aging, better than PTFE, EFP in high temperature

3. Injection molding for higher negative pressure

1. 40~180℃

2. Strong corrosion medium, like strong acid and alkali

3. Healthcare mdium

FEP(F46)

1. Hydrophobicity and non-viscous

2. Corrosion resistance is inferior to PFA

3. Negative pressure

1. 40~180℃

2. Strong corrosion medium, like strong acid and alkali

3. Healthcare mdium

 

 

5. Selection of Electrode Materials

Electrode MaterialMain Performance
316LGood corrosion resistance of nitric acid, sulfuric acid, acetic acid, alkaline liquid at room temperature < 5%, sulfite, seawater, acetic acid and other corrosion under certain pressure, can be widely used in petrochemical urea, vinylon and so on.
HbGood resistance to all concentrations below the boiling point of hydrochloric acid, but also resistant to non-oxidizing acid, alkali, sulfuric acid, phosphoric acid, hydrofluoric acid, organic acid corrosion.
HcResistant to the corrosion of oxidizing acid, such as nitric acid and mixed acid. The mixture of chromic acid and sulfuric acid, oxidized salts, such as Fe3+, Q3+, and other oxidants, such as the mixture of hypochlorite solution and seawater at higher than normal temperature.
TiResistant to corrosion of seawater, various chlorides, hyalphates, oxidizing acids (including smoke nitric acid), organic acids or alkalis, but not pure reduced acids (e.g. sulphuric acid, hydrochloric acid). However, if the acid contains oxidants (e.g. nitric acid, Fe3, Q3), corrosion resistance is reduced.
TaGood corrosion resistance similar to glass. Resistance to the corrosion of chemical medium(including hydrochloric acid and fumiing sulfuric acid), but can not be used for sodium hydromide fluid.
Pt-IrHave good corrosion resistance of all acid, and can be resistance to the corrosion of alkali, all salt except aqua regia, ammonium slat and few other medium
Tungsten CarbideFor pulp and sewage, good resistance to solid particle interference.

 

6. Dimensional Sketches

a. Dimension of Converter

                                                                      Divided Type

 

 

                                                                      Integrated Type

 

                                                                  Battery Powered Type

 

 

b. Dimension of Sensor

 

 

Pipeline DiameterDimension
LWH
1516095130
20160105137
25160115150
32160135160
40200145175
50200160185
65200180205
80200195215
100250215235
125250245275
150300280300
200350335355
250400400405
300500455460
350500515520
400600575580
450600635630
500600710685
600600835795
700700905910
80080010201030
90090011201120
1000100012451250
1200120014651470

 

6. Configuration

MLF Series Electromagnetic Flow Meter Configuration
ModelMLF
Sensor InstallationSFlange Type Sensor
CInsertion Type Sensor
OOthers
Pipeline Diameter1010mm
1515mm
2020mm
...... 
20002000mm
Electrode InstallationFStandard Fixed Type
Electrode MaterialA316L SS
BHb
CTa
DTi
EHc
FTungsten Carbide
GOthers
Liner MaterialRRubber
PPTFE
OOthers
Pipe MaterialB304 SS (Standard)
C316 SS
Flange TypeGGB (Standard)
AANSI
JJIS
BBS
OOthers 
Flange MaterialA304 SS
B316 SS
C#20 Carbon Steel (Standard)
Cover MaterialD304 SS
E316 SS
FCarbon Steel+ Epoxy Metallic Paint (Standard)
Matching Flange0Without Matching Flange (Standard)
1With Matching Flange
Ground Ring0Without Ground Ring (Standard)
1With Ground Ring
Rated Pressure101.0MPa
161.6MPa
252.5MPa 
404.0MPa
Working TemperatureE≤60℃
H≤180℃(Divided Type)
TypeIIntegrated Type
DDivided Type
OutputPPulse
A4-20mA
GRS485
HHart
QOthers
Power Supply0220VAC
124VDC
2Battery-powered
Protection Class0IP65 (Integrated/Divided Type)
1IP67 (Divided Type)
2IP68 (Divided Type)
Other FeaturesRHeat Energy Function
PWith PT1000
BWithout PT1000
Explosion Proof0None
EXExplosive Proof

 

Hot Products

Clamp Type Electromagnetic Flow Meter Stainless Steel with 220VAC / 24VDC / Battery Powered 1. ...
Electromagnetic Flow Meter with English / Korean / Polish / Turkish / French / Portuguese Language ...
Electromagnetic Flow Meter for Textile Industry / City Administration / Water Works / Environment ...
Compact Type Electromagnetic Flow Meter with High Temperature of 130℃ / 150℃ /180℃ for Option 1. ...
Compact Type Electromagnetic Flow Meter SS Material with 0.3 - 10m/s Velocity Range​ 1. Introduction ...
Remote Type EMF Electromagnetic Flow Meter with 316L / Hb / Hc / Ti / Ta / Pt-Ir Electrode Material​ ...