                               DN80 Integrated EMF Electromagnetic Flow Meter with Cheap Price China

 

1. Introduction

1. The MLF electromagnetic flowmeter works according to Faraday's law of electromagnetic induction and consists of a sensor and a transducer. Used to measure the conductivity of a liquid or solid. In general, its conductivity should be greater than 5μS/cm (tap water, raw water conductivity of about 100 ~ 500μS/cm), can also be used to measure acid, alkali, salt water, pulp or pulp and other media. However, these media should not contain large amounts of magnetic material and air bubbles.

MLF electromagnetic flowmeter is a kind of instrument to measure liquid fluidity. Widely used in metallurgy, chemical industry, paper making, environmental protection, petroleum, textile, food, urban management, water plant and other industries flow measurement.

 

 

2. Quick Details

1). It is high resistance, fast response design can make undistorted collection of weak signal and fast response to the flow changes. Its range rate can reach 100:1.

2). It has the function of low conductivity measurement.

3). It has the consistency of converter’s interchange, which can avoid input parameters repeatedly.

4). Wide range of power supply mode is available (DC: 18V-36V/AC: 85V-265V).

5). It is the first domestic company that adopts the function of saving settings before delivery,which can avoid the loss of the parameters.

6). It adopts the international leading excitation technology, which circuit is simple, stable,and reliable.

7). It has the function of infrared remote control and button operation so as to make the operation more convenient.

8). It provides the function of zero correction of sensor and automatic zero adjustment.

9). It has Chinese, English, Korean, Polish, Turkish, French and Portuguese languages for option to satisfy different customers’ requirements.

 

 

3. Specification

MLF TypeDivided TypeIntegrated TypeExplosive Proof Integrated TypeBattery Powered TypeHeat Energy Type
Accuracy±0.2% or ±0.5%
Pipeline DiameterDN10-DN2000DN10-DN600DN25-DN2000
FlangeGB, ANSI, JIS, BS, Others
PressureDN10-DN600 1.0 1.6 2.5 4.0MPa
DN700-DN2000 0.6 1.0 1.6MPa
Liner MaterialCR, PTFE, PU, Hard Rubber, PFA, FEP(F46)
Conductivity≥5µs/cm(Please contact us if it is less than 5µs/cm)
Electrode316L SS, Hb, Ta, Ti, Hc, Tungsten Carbide, Others
Protection ClassIP65, IP66, IP67, IP68
Medium Temperature-25~180
(Please refer to liner material)
-25~80(Please refer to liner material)-25~180
(Please refer to liner material)
Ambient Temperature for Accuracy Influence<±0.1%/10 or <±0.25%/10 at the ambient temperature of -25~60
Repetability≤±0.1% or ±0.25%
Analog Output Error≤±0.02mA
Velocity0.3~10m/s
Electrical connectionM20x1.5 Seal Cartridge, GB1/2, NPT1/2
Output4-20mA, Pulse, RS485, Hart, Profibus

 

4. Selection of Electrode Materials

Electrode MaterialMain Performance
316L

Good corrosion resistance of nitric acid, at room temperature <5% sulfuric acid, acetic acid, alkaline liquid, a certain pressure of sulphate, seawater, acetic acid and other corrosion, can be widely used in petrochemical urea, veline and so on.

Hb

Good resistance to all concentrations of hydrochloric acid below boiling point, as well as non-oxidizing acid, alkali, sulfuric acid, phosphoric acid, hydrofluoric acid and organic acid.

Hc

Corrosion resistance of oxidizing acids, such as nitric acid and mixed acid. A mixture of chromic acid and sulfuric acid, oxides, such as Fe3+,Q3+, and other oxidants, such as a mixture of hypochlorite solution above normal temperature and seawater.

Ti

Resistant to corrosion of seawater, various chlorides, hypochlorite, oxidizing acids (including fuming nitric acid), organic acids or bases, but not pure reductive acids (e.g., sulfuric acid, hydrochloric acid) etc. but if the acid contains oxidants (such as nitric acid, Fe3,Q3), the corrosion resistance will decrease.

TaGood corrosion resistance similar to glass. Resistance to the corrosion of chemical medium(including hydrochloric acid and fumiing sulfuric acid), but can not be used for sodium hydromide fluid.
Pt-IrHave good corrosion resistance of all acid, and can be resistance to the corrosion of alkali, all salt except aqua regia, ammonium slat and few other medium
Tungsten CarbideFor pulp and sewage, good resistance to solid particle interference.

 

 

5. Dimensional Sketches

a. Dimension of Converter

                                                                      Divided Type

 

 

                                                                      Integrated Type

 

                                                                  Battery Powered Type

 

 

b. Dimension of Sensor

 

 

Pipeline DiameterDimension
LWH
1516095130
20160105137
25160115150
32160135160
40200145175
50200160185
65200180205
80200195215
100250215235
125250245275
150300280300
200350335355
250400400405
300500455460
350500515520
400600575580
450600635630
500600710685
600600835795
700700905910
80080010201030
90090011201120
1000100012451250
1200120014651470

 

6. Configuration

MLF Series Electromagnetic Flow Meter Configuration
ModelMLF
Sensor InstallationSFlange Type Sensor
CInsertion Type Sensor
OOthers
Pipeline Diameter1010mm
1515mm
2020mm
...... 
20002000mm
Electrode InstallationFStandard Fixed Type
Electrode MaterialA316L SS
BHb
CTa
DTi
EHc
FTungsten Carbide
GOthers
Liner MaterialRRubber
PPTFE
OOthers
Pipe MaterialB304 SS (Standard)
C316 SS
Flange TypeGGB (Standard)
AANSI
JJIS
BBS
OOthers 
Flange MaterialA304 SS
B316 SS
C#20 Carbon Steel (Standard)
Cover MaterialD304 SS
E316 SS
FCarbon Steel+ Epoxy Metallic Paint (Standard)
Matching Flange0Without Matching Flange (Standard)
1With Matching Flange
Ground Ring0Without Ground Ring (Standard)
1With Ground Ring
Rated Pressure101.0MPa
161.6MPa
252.5MPa 
404.0MPa
Working TemperatureE≤60℃
H≤180℃(Divided Type)
TypeIIntegrated Type
DDivided Type
OutputPPulse
A4-20mA
GRS485
HHart
QOthers
Power Supply0220VAC
124VDC
2Battery-powered
Protection Class0IP65 (Integrated/Divided Type)
1IP67 (Divided Type)
2IP68 (Divided Type)
Other FeaturesRHeat Energy Function
PWith PT1000
BWithout PT1000
Explosion Proof0None
EXExplosive Proof

 

Hot Products

IP65 Thread Type Industrial Flow Meter Turbine Flow Transmitter Simple Structure 1. Introduction ...
DN50 Flange Type Turbine Type Flow Meter Battery Operated Compact Structure 1. Introduction LWGYML ...
DN50 High Precision Industrial Flow Meter Vortex Steam Flow Meter Pulse Output 1. Introduction ...
SS304 Sanitary Electromagnetic Flow Meter for Beverage Industries DN15-DN2000 1. Introduction MLF ...
DN80 Integrated EMF Electromagnetic Flow Meter with Cheap Price China 1. Introduction 1. The MLF ...
Differential Pressure Transmitter with 316L Stainless Steel Diaphragm 1. Overview The ML3000 series ...