                                   Hydrostatic Level Transmitter with Long Service Life for Easy Maintance

 

1. Introduction

ML2000T series static liquid level transmitter adopts imported silicon pressure transducer as sensitive element, utilizing reasonable industry structure to finish stainless steel sealing package. The amplifying circuit can ensure measurement accuracy through laser compensation . The electrical connection cable applies is anti corrosive gas shielded cable which makes the back pressure chamber is directly connected to the atmosphere. 

 

2. Features

  • The tested medium is extensive. As long as the liquid is compatible with the diaphragm material and the paste, it can be measured.
  • The lifetime is long for it has stainless steel material, reasonable sealing package and special cable.
  • It has high accuracy and good stability. The transducer realizes temperature compensation with 0-85℃ and eliminates accuracy influence caused by temperature drift through compensation circuit.
  • ML2000T series is easy installed. Just immerse the probe into medium directly and connect the signal cable to secondary instrument. Adapt to small installation space. When installation, please try to fix the cable to avoid shaking of transducer for shaking can influence the accuracy and lifetime of the transducer.
  • Upgrade features:

① Power supply non polar connection

② Field or Outside lightning prevention design

 

 

3. Technical Parameter

Accuracy±0.2% or ±0.1%
Measuring Range0~200mH2O
Stability<0.1%FS Per Year
Overload Limit200%
Power Supply24VDC or 12VDC
Signal OutputTwo-wired 4-20mA
Overload Limit150%~300%
LagFull Span Better Than 0.01%
Working Temperature0~85℃
Storage Temperature85℃

 

 

4. Structure & Material

Isolation Diaphragm316L Stainless Steel
Transducer:Stainless Steel(Cylinder Shape)
Sealing:Fluorine Rubber
Cable:PVC Cable With Shield
Product TypesCommon, Oil Resistance, Corrosion Resistance

 

 

5. Configuration

TypeSpecification CodeIllustration
ML2¨¨¨T---------------------------------Static Liquid Level Transmitter
Transducer0--------------------------------Diffused Silicon Transducer
Accuracy8--------------------------------±0.2%
5--------------------------------±0.1%
Output8--------------------------------4-20mA
1--------------------------------4-20mA, HART, RS485
 T-------------------------------- 
Measuring ModeA--------------------------------Common Type *
G--------------------------------Oil Resistance Type(0~200℃)
N--------------------------------Corrosion Resistance Type
K--------------------------------Lightning Stroke Resistance Type
Dimension RequirementsL--------------------------------Cable Type (Note 1)
G--------------------------------Rod Type (Note 2)
Measuring Range1--------------------------------0-1000mmH2O
2--------------------------------0-5000mmH2O
3--------------------------------0-10000mmH2O
4--------------------------------0-20000mmH2O
5--------------------------------0-30000mmH2O
6--------------------------------0-60000mmH2O
7--------------------------------0-100mH2O
8--------------------------------0-150mH2O
9--------------------------------0-200mmH2O
Display HeaderD--------------------------------Multiple Parameters & Modes Digital LED Display Header With HART
L--------------------------------Common LED Header Without HART
Z--------------------------------Pointer Header
N--------------------------------No Header
Electrical Connection5--------------------------------M20x1.5 Waterproof Concentrator
Power Supply-A--------------------------------24VDC
-B--------------------------------12VDC
Additional Type-FL------------------------------Flange Connection (Note 3)
-NF1----------------------------Ex-proof Certificate: Exd II CT6
-NS1----------------------------Intrinsic Safety Type: Exi II CT4
-M-------------------------------Other Requirements (Note 4)
Remarks:  
e.g.:ML2088TAL2N5-A-NF1 0-5000mmH2O
Note1: Please indicate cable length behind type if you choose this code
Note2: Please indicate rod length behind type if you choose this code(Max.3m)
Note3: Please indicate flange size behind type if you choose this code
Note4: Please note in order
*: Standard  
Order Attention:  
1. Indicate the ambient temperature and medium temperature if it is corrosive.
2. Indicate medium density.

 

 

6. Details

 

Hot Products

4 - 20mA Intelligent Hydrostatic Level Transmitter with LED Display 1. Introduction ML2000T series ...
Hydrostatic Level Transmitter with Long Service Life for Easy Maintance 1. Introduction ML2000T ...
Hydrostatic Level Transmitter with Two-wired Analog for Industry 1. Introduction ML2000T series ...
Smart Liquid Level Transmitter Stainless Steel Sensor Fluorine Rubber Sealing 1. Introduction ...
Diffusion Silicon Hydrostatic Level Transmitter with 5 Meter Cable Flange Type 1. Introduction ...
Intelligent Hydrostatic Level Transmitter with 4 - 20mA Output LED Display 1. Introduction ML2000T ...