Circular Saw Switch Endurance And Lower Guard Recovery Time Integrated Test Device CSG-2

 

Standard: EN 60745-2-5: 2010 Annex M21.18, Annex M21.18.301, Annex M21.203, Annex M21.301, figure M.301, IEC60745-2-5:2003 Annex BB.20.102, EN 60745-2-5:2010 clause 17.101 and clause 19.102.3.

 

Application: It is used to test the circular saw switch performance and circular saw lower guard’s durability and recovery time.

 

Test sample: Circular saws

 

Feature: This equipment is composed of two parts, the mechanical system and electrical control system.

 

Mechanical system is the table for circular saw. There are a switch and sample socket on the table, operator can push the switch to turn on or off the load power supply to the test sample; different sizes of circular saws can be placed and fixed on the table; on the table, device for locking the switch of the hand-held circular saw in the “on” position; the blade can extend to the bottom of the table through the middle groove; on the table where under the blade, there are a the lower guard putter and two position sensors , which can be drive the lower guard of the circular saw to be opened or closed.

 

The electrical control system consists of the load power supply, MITSUBISHI PLC, 7 Inch Touch screen and etc. Can achieve manual operation and automatic operation.

 

Manual control:

The operator can manually move the lower guard putter by press “Manually Rotate Clockwise” or “Manually Rotate Counterclockwise” on touch screen, then the lower guard gradually open or close, when the putter makes the lower guard to be opened to the maximum open position (corresponding position sensor indicator is lighting), at this time, operator can stop the lower guard opening action; and operator can manually make the circular saw switch to be ON or OFF by pressing “Switch On Manually” or “Switch Off Manually” on the touch screen, the switch locking device can automatically lock or release the switch of the circular saw. Operator can press the Stop button on the panel to achieve to supply or not supply load voltage to the test sample.

 

Automatic operation:

 

1. Operator can pre-set the interval time of the locking device lock or release the circular saw switch, the interval time of the load voltage supplied to the test sample, and the opening residence time of the lower guard of the circular saw, after that, operator only press “Start” on touch screen, the above testing for the circular saw switch will be processed automatically.

 

 2. The following is mainly for the circular saw lower guard’s durability and recovery time test : The saw is to be set for a 90°cut and oriented in the horizontal plane. The lower guard is to be cycled from the full closed position to the maximum open position and then released for 50 000 cycles at a rate not less than 10 cycles per minute, the number of times is recorded by the position sensor. The close time of the lower guard is not less than 0.3s, if exceed 0.3s, then the number of a timeout is counted. The close time of the lower guard of the last time is recorded after the equipment runs to the required test times, and the equipment will automatically stop.

 

Technical Parameters

 

No.:Serial No.:ParameterRemark
1Input Power220V/50Hz 
2Control SystemMitsubishi PLC, 7-inch touch screen 
3StationOne 
4Built-in Load0~250V/5KW voltage regulator, equipped with B socket 
5Test Cycles0-999999, can be preset 
6Test Speed≥10 freq/min 
7Guard Recovery Detection Time0.01-9.99s, can be displayedRecovery time
8Circular Saw Switch Locking DeviceLock or release the switch by motor driving 
9Operation ButtonsStop and Start buttons on the panel for operator easily cut off or turn on the power 
 

Hot Products

Circular Saw Switch Endurance And Lower Guard Recovery Time Integrated Test Device CSG-2 Standard: ...
Dielectric Strength Test Instrument HX9801 Description: This device is used to test the dielectric ...
Mandrel Test Device HX9804 Description: This device is used to test the Insulation anti damage ...
IEC60811 - 1 - 2 Oxygen Bomb Aging Tester IEC Test Equipment For Wire And Cable Standard: IEC60811-1...
Touch Current Measuring Circuit Figure 5 Network Of IEC 60990 For Leakage Product description: This ...
IEC60335 Testing Equipment Of Plc Control System 1000mm Adjustable Automatic Cord Reels Endurance ...