Home Companies Chongqing Bosun Electrical Co., Ltd.

SF6 Air Insulated Metal Clad Power Compact Transformer Substation Uses SCADA

Chongqing Bosun Electrical Co., Ltd.

Contact Us

[China] country

Trade Verify

Address: No.18 Shigui Avenue, Jieshi Town, Banan District, Chongqing,China

Contact name:Shirley

Inquir Now

Chongqing Bosun Electrical Co., Ltd.

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

SF6 Air Insulated Metal Clad Power Compact Transformer Substation Uses SCADA

Country/Region china
City & Province chongqing chongqing
Categories Other Roadway Products
InquireNow

Product Details

SF6 Air Insulated Metal Clad Impact Test Power Distribution Transformear

 

 

Product Description

 

Control systems

 

• Local control involves operators manually operating equipment at the substation.

• Remote control uses SCADA and communication systems to operate the substation from a control center.

• Automatic control employs relays, logic controllers and processors to regulate operations with minimal operator intervention.

 

Protection systems

 

• Overcurrent protection uses fuses and circuit breakers to detect and interrupt fault currents.

• Differential protection compares currents at the two ends of a transmission line or transformer to detect internal faults.

• Directional protection determines the direction of a fault to selectively isolate the affected section.

• Distance protection monitors impedance to detect faults at a certain distance from the substation.

 

Faults and failures

 

• Insulation failure is a major cause of faults and outages in substations. It can occur due to overvoltage, excess heat, contamination, etc.

• Temporary overvoltages from lightening, faults and switching can damage insulation if adequate arresters are not provided.

• Overloading of lines and equipment beyond their ratings can cause damage, overheating and failure.

• Human error during maintenance and ops can also lead to equipment damage and outages.

• Fires are a significant hazard in substations due to the presence of flammable insulating oil and other combustible materials.

 

Specification

 

 

Rated Voltage12/17.5/24kV36kV

 

Standard applicable

IEC 62271 – 202 (IEC 61330)IEC 62271 – 202 (IEC 61330)
Normal ambient temperature40 ° C40 ° C
Maximum ambient temperature50 ° C50 ° C
Enclosure constructionModularModular
VentilationNaturalNatural
Temperature class (Std.)K 10K 10
MV and LV compartmentIP 54IP 54
Transformer compartmentIP 23IP 23
Rated voltage (kV)12/24kV36kV
Power frequency (kV rms)28/5070
Impulse (kV p)75/125170
Rated frequency (Hz)50/6050/60
Rated normal current (A)630630
Breaking capacity (A)630630
Making capacity (kA)52.5 / 4050
Rated normal current (A)630630
Breaking capacity (kA)21/1620
Making capacity (kA)52.5 / 4050
Rated power (kVA) – oil type25002000
Rated power (kVA) – Dry type25002000
Rated secondary voltage (V)433433
Vector groupDyn 11Dyn 11
Tapping range+ 5 in steps of 2.5%+ 5 in steps of 2.5%
IPYesYes
Internal arcYesYes
Enclosure classYesYes
Impact testYesYes
Short circuit test on earthingYesYes

 

 

Team Show

 

 

1.Professional team

 

2.Comprehensive services

 

3.Strict quality control

 

4.Comprehensive inspection

 

5.Responsibility guarantee

 

 

Engineering

 

1.Power generation plants

 

2.Substations

 

3.Commercial buildings

 

4.Data centers

 

5.Renewable energy systems

 

6.Transportation

 

 

Why Choose Us

 

 

 

1.Our Expertise

 

2.Quality Products/Services

 

3.Competitive Pricing

 

4.Innovation

 

6.Possibles

 

7.Authorization by ABB Schneider Siemens

 

Hot Products

3 Phase 4 Phase IP4X IP65 High Voltage Switchgear Pad Mounted Transformer Product Description Box...
15KV GGD Main LV Photovoltaic Power Generation Compact Transformer Substation Product Description ...
Arc 600V MNS Power Distribution Equipment Compact Transformer Substation Product Description Box...
Medium Voltage Low Voltage 480V Outdoor Type Power Distribution Substation Product Description Box...
SF6 Air Insulated Metal Clad Impact Test Power Distribution Transformear Product Description Control ...
4 Phase Power Supply Substation for Electrical Grid Systems and for Highway Product Description ...