Uonel Co.Limtied |
|
H802EPFD/H803EPFD Board
The H802EPFD/H803EPFD is an 16-port EPON OLT interface board. It works together with the optical network unit (ONU) to provide EPON access services.
Feature and Specifications
EPON Service Board Comparison
In the table, "Yes" indicates "supported" and "No" indicates "not supported".
Table 1 Specifications lists of EPON service board
Specification | H802EPFD/H803EPFD |
Port quantity | 16 |
MAX Split ratio | 1: 64 |
Optical Module | SFP |
Prevent IP spoofing | Yes |
Prevent MAC address spoofing | Yes |
prevent DOS attacks | Yes |
Optical performance monitor | Yes |
Controlled optical signal transmission of the optical module | Yes |
Temperature query and high temperature alarm | Yes |
Automatic power shutdown in case of a high temperature | Yes |
1588v2 | Yes |
Maximum Number of Service Flows Supported by the Board | 16368 |
Maximum Number of Service Flows Supported by the LLID | 4096 |
Parameters
Power Consumption and Maximum Frame Size of Boards
You can query power consumption, maximum frame size, and normal operating temperature of all boards.
lists the power consumption and maximum frame size of boards. "-" indicates N/A.
The operating temperature of all the boards is -40°C to +65°C. The lowest board startup temperature is -25°C.
NOTE:
The power consumption of the board is tested in the following conditions:
Working voltage: -53.5 V DC.
Ambient temperature: 25 °C.
Static power consumption: All ports do not carry any loads. Specifically, users under POTS ports hang up phones, xDSL ports are deactivated, and optical modules are not installed on optical ports
Maximum power consumption: All ports fully carry loads. However, only 25% users under POTS ports concurrently pick up phones and the feeding current is 20 mA.
The board power consumption slightly varies with the power module configured for the board and discreteness of components.
Table 1 Power consumption and maximum frame size of boards
Board | Power Consumption | Maximum Frame Size |
H802EPFD | Static: 43 W Maximum: 62 W | 1996 bytes |
H803EPFD | Static: 25 W Maximum: 43 W | 1996 bytes |
Working Principle
Indicates the channels of control signals. | Indicates the channels of service signals. | ||
Indicates the control module which loads the board software, controls the running of the board, and manages the board. | Indicates the service modules which the service signals pass through. |