50KV AC Hipot Tester VLF Ultra-Low Frequency High Voltage Generator Lab Equipment

 

Application:


VLF insulation withstand voltage test is an alternative test method for the power frequency withstand voltage test.The test procedure is greatly reduced, which is more advantageous than the power frequency test. It can be widely used in the AC withstand voltage test of cables, large high voltage rotary motors and power capacitors.This product combines the advanced technology of modern digital frequency conversion, adopts microcomputer control, step-up, step-down, measurement, protection fully automatic, and can perform manual intervention in the automatic promotion process. Because of the full electronic, the volume small weight light, large screen liquid crystal display, clear and intuitive, and can display the output waveform, print output test report. In addition, the following features need to be specified:

Product Features:

 

1. No need to connect extra protection reactor because of high voltage protection reactor inside booster.
2. Over-current protection:double protection for high and low voltage, stop running accuracy protect high voltage according to set parameter, stop running when low voltage current over rated current, time <20ms.
3.Due to use high and low voltage closed loop control circuit, output without capacitive rise effect.

4. Real and accuracy test results of current, voltage, waveform directly get from high voltage lateral sampling.
5.Over-voltage protection: device stop running when output over setting max voltage, time <20ms.

 

Main Parameters:


1, Related output voltage:see sheet 1
2, Output Power:0.1Hz,0.05Hz,0.02Hz
3, On load capacity:see sheet 1
0.1 Hz
Max1.1 μf

0.05 Hz Max2.2 μf
0.02 Hz Max5.5 μf
4, Measurement Accuracy:1%
5, Voltage Plus&Minus Peak Value Error:≤3%
6, Voltage Waveform Distortion:≤5%
7, Working Condition:indoor,outdoor; temperature:-10ºC∽+40ºC;humidity:≤85%RH
8, Power Supply:AC 50 Hz/60Hz,220V ±5%
9, Power source protective-tube:See sheet 1

 

ModelRelated voltageOn-load capacityPower source protective-tubeWeight
30KV30kV/20mA
(peak value)
0.1Hz,≤0.5µF~1.1µF5AController:4kg
Booster:25kg
0.05Hz,≤0.5µF~2.2µF
0.02Hz,≤0.5µF~5.5µF
50KV50kV/30mA
(peak value)
0.1Hz,≤0.5µF~1.1µF7AController:4kg
Booster:50kg
0.05Hz,≤0.5µF~2.2µF
0.02Hz,≤0.5µF~5.5µF
60KV60kV/30mA
(peak value)
0.1Hz,≤0.5µF9AController:4kg
Booster1(30kV):25kg
Booster2(30kV):25kg
0.05Hz,≤0.5µF~1µF
0.02Hz,≤0.5µF~2.5µF
80KV80kV/30mA
(peak value)
0.1Hz,≤0.5µF12AController:4kg
Booster1(30kV):25kg
Booster2(50kV):50kg
0.05Hz,≤0.5µF~1µF
0.02Hz,≤0.5µF~2.5µF

 

Quality Guarantee: One year quality guarantee after shipment. 

Hot Products

15kVA/150kV Partial Discharge Lab Equipment PD Test System Application: It is mainly used for ...
AC 100kVA/500kV free Partial Discharge Testing System High Voltage Test Set PD test Application: It ...
HV PDF PD Free AC Testing System No Partial Discharge AC Dielectric Test Set Product Description: It ...
Cascade AC Testing System No Partial Discharge AC Dielectric Test Set Product Description: It is ...
50KV AC Hipot Tester VLF Ultra-Low Frequency High Voltage Generator Lab Equipment Application: VLF ...
Vlf 0.1Hz Low Frequency High Voltage Cable Tester AC Hipot Tester How to choose the suitable ...