Inductance Adjustable AC Voltage Withstand Resonant Test System for Generators High Voltage Test Equipment

 

Introduction

ZXGXZ Resonant test system for Generators require the use of power frequency voltage withstand voltage, the current national standard factory frequency voltage frequency defined as 45Hz ~ 65Hz, but in many test situations, requirements of generator is 50Hz plus or minus 2Hz ac testing, and generator stator winding of electric capacity is larger, the domestic most current test unit USES a resonant transformer to test it, but the resonant transformer itself is very heavy, field test is very inconvenient. Our company has designed and developed a frequency modulated induction generator ac compressive resonance device.

 

Features

1. As the resonant system is reactive power full compensated, the power of the equipment and power source is only less than 1/10 of measured equipment; with smaller volume and lighter weight compared with the equipment in same capacity. The device with large output capacity and small power supply capacity, low cost, easy to operate and safe.

2. Serial resonant system actually is current filter circuit, which make the tested equipment through current almost being fundamental current, the output voltage distortion (THD) is very small, better than current AC voltage withstand equipment.

3. The short circuit current after flash-over or breakdown is only less than 1/10 (1/Q) of the test current before the short-circuit, which can effectively prevent further damage to fault point after breakdown.

4. Auto blowout the arc after flash-over, which is a long and stable process to recover the serial resonant voltage, so it is very safe.

 

Technique parameter:

Rated output voltage≤0~60kV(AC effective value)
Output frequency50Hz
Resonant voltage waveformSine wave, distortion ≤1%
Working modeFull power continuous working time: 1min
Quality factor10~40
Maximum measured capacity≤3000kVA
Power supply380V±15%, frequency:50Hz

 

Serial product and application:

ModelApplication (AC voltage withstand test for generator with output voltage ≤20kV, frequency: 50Hz±2Hz)
Control cabinetReactorExcitation transformerDividerApplication
ZX-GXZ-100/5010kW/220V50kV/1A1010kW/5kV50kV/500pFGenerator 0.07~0.13uF
2 sets10kVcable(300mm2)≤1.0km
ZX-GXZ-150/5015kW/380V50kV/1.5A 2 sets15kW/5kVGenerator 0.13~2uF
10kVcable(300mm2)≤1.5km
ZX-GXZ-225/5025kW/380V50kV/1.5A 3 sets,25kW/5kVGenerator 0.2~0.27uF 10kVcable(300mm2)≤2.5km
ZX-GXZ-350/5030kW/380V60kV/2A 3 sets30kW/5kVGenerator 0.27~0.33uF

 

Note: solution to make according to the measured equipment.

 

Product Gallery

 

 

 

Hot Products

Inductance Adjustable AC Voltage Withstand Resonant Test System for Generators High Voltage Test ...
ZXBXZ Series Resonant Test System for Substation Product introduction This ZXBXZ Series Devices are ...
ZXBXZ Series Resonant Test System for Substation Product introduction This ZXBXZ Series Devices are ...
Resonant test system for CVT This resonant tester is widely used for Capacitive Voltage Transformer ...
High Voltage Resonant Test System Inductance Adjustable AC High Voltage Resonant Test System For ...
ZXBXZ Series Resonant Test System for Substation Product introduction This ZXBXZ Series Devices are ...