Home Companies herong electric

600kvar~9000kvar Reactive Power Compensation Device

herong electric

Contact Us

[China] country

Trade Verify

Address: NO.9 XIJIN RD, JINGWEI INDUSTRIAL PARK, ECONOMIC AND TECHNOLOGY DEVELOPMENT ZONE, XI'AN CITY, SHAANXI PROVINCE, CHINA

Contact name:Amanda

Inquir Now

herong electric

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

600kvar~9000kvar Reactive Power Compensation Device

Country/Region china
City & Province Shaanxi
Categories Other Chargers
InquireNow

Product Details

Automatic switching and reactive power compensation devices with multiple steps

1.Overview

The multi-group automatic switching reactive power compensation device is based on the conventional high-voltage parallel capacitor device, which adds a special switching switch and automatic switching controller for the capacitor bank to realize the grouped automatic switching of the capacitor reactive capacity to achieve reactive power compensation,to achieve the purpose of reactive power compensation.

The device is mainly composed of capacitor bank, isolation switch, high-voltage vacuum circuit breaker or high-voltage vacuum contactor, discharge coil, current transformer, reactor, etc.

2. Purpose

It is mainly used in 6 ~ 35kV power system to improve the power factor of the system, reduce the loss of transformers and lines, and improve the quality of power supply. The device is widely used in chemical, petroleum, metallurgical, and coal systems to maximize the compensation of reactive power of the system. The controller in the device adopts the "nine-domain zone" control principle and various operating modes to prevent the switching from oscillating. The device also has an RS-485 communication interface, which can realize four remote functions and can be connected with the substation integrated automation system.

3. Technical features

(1) The special vacuum switch used for capacitors has passed the back-to-back test of capacitive switching of capacitors, which is suitable for frequent switching.
(2) The automatic compensation is divided into two to five switching channels, with high compensation accuracy and low impact, which can obtain the maximum reactive power compensation effect.
(3) Controller uses intell6 bit microcontroller, large-screen character display menu, has a friendly interface, real-time display operating parameters and fault information; with a RS-485 communication interface, four remote functions, and can be integrated substation automation interface, Realize the three aspects of control and management: on-site, background machine and scheduling.
(4) The controller adopts the "Nine Domains" control principle to automatically identify various operation modes of transformers and capacitors in the substation to prevent switching shocks.
(5) Each capacitor is equipped with overcurrent protection and internal fault protection, which can isolate faulty capacitors in time and effectively, and has a voice alarm function to ensure the overall safe and reliable operation.

 

4.Model Description

E.g:TBBZ10-1000×3-AK

T:complete device

BB:Parallel compensation

Z:Automatic grouping

10:System nominal voltage 10kV

1000×3:Rated capacity 3000kvar, divided into 3 paths, each path capacity is 1000kvar

A:Singel-star-type wiring

K:Open triangle voltage protection

5.Technical data

Rated voltage6,10kV
Rated Capacity600~9000kvar
Maximum capacity of single group≤2000kvar
Series reactance rate1%,5%,12%
Installation methodIndoor products adopt cabinet structure, outdoor products adopt box-type structure or frame structure
Contral path2~5 paths, two paths can be selected when more than 5 channels
Control physical quantity2~5 paths vacuum switch
Input physical quantityCurrent (5A/1A), voltage (100V) at the bus outlet
ProtectOver current, over voltage, loss of voltage, internal fuse + open triangle voltage protection
Displaycurrent, voltage, power factor, operating state of each group of capacitors
Operation modeAutomatic, manual optional
Altitude≤2000
Environmental temperature category-40/D
Ambient relative humidity (at 25℃) daily average value95%, monthly average value 90%
Earthquake intensity8 degrees, horizontal acceleration 0.3g, vertical acceleration 0.2g

6.Order description


Please provide the following data when ordering:

  • Capacity to be compensated
  • System operating voltage
  • Reactance rate
  • Field installation size
  • Conditions of use (indoor or outdoor)

Our company can provide technical support and parameter calculation, if you have special requirements, please specify when ordering.

Hot Products

12.1KV High Voltage Shunt Capacitor 484kVar - Power Capacitor - Capacitor Bankank 1. Overview of 12...
6.929KV High Voltage Shunt Capacitor 450kVar - Power Capacitor - Capacitor Bankank 1. Overview of 6...
Automatic switching and reactive power compensation devices with multiple steps 1.Overview The multi...
12.65KV High Voltage Shunt Capacitor 344kvar - Power Capacitor - Capacitor Bank 1.Overview of 12...
High Voltage 6.6kv Capacitor Shunt Type With Capacity 25kVar 1. Overview of High Voltage 6.6KV ...
High Voltage Shunt Power Capacitor BAM6.6-50-1W, High Voltage Capacitor Main features of High ...