Pharmaceutical Sterile Clean Room with GMP standard

Important Considerations for Operating a Sterile Cleanroom:

 

The use of sterile cleanrooms in the manufacture of food and beverage products follows the same principles that are laid out in the GMP (Good Manufacturing Practice) for pharmaceutical manufacturing. The goal is to minimize potential contaminants in the form of dust particles and microorganisms in order to increase product safety and quality.

 

(1) For personal safety reasons, all personnel entering the cleanroom should first turn off all UV lights.

(2) Sterile cleanrooms and buffer areas should be designed to meet FS209E level 10,000 (ISO 7). Cleanroom temperature should be maintained between 20-24℃ with a humidity level between 45-60%. All workstations should meet FS209E level 100 (ISO 5).

(3) In order to maintain a sterile environment, strict precautions must be taken to avoid contamination of the cleanroom and any cleaning equipment. Operator should immediately discontinue use of any contaminated equipment or item.

(5) The cleanroom should be cleaned regularly with a disinfecting agent.

(6) Any machinery, device, lab equipment, etc. should be thoroughly disinfected and sealed before it is taken into the sterile cleanroom.

(7) All personnel must disinfect their hands with soap and/or disinfectant before entering the buffer area. In the buffer area, they should then change put on shoes and clothing approved for use in the clean area, and also put on approved hats/hairnets, masks, and gloves (or wash their hands again with hand disinfectant.)

(8) Before using the sterile cleanroom, the UV lights should be turned on for at least 30 minutes. At the same time, the fans on the clean benches should be turned on. After turning out the UV lights, cleanroom surfaces should be thoroughly cleaned with disinfectant, and then the UV lights should be turned on for another 20 minutes.

(9) When inspecting test samples make sure that the packaging is completely sealed, and do not open the packaging in order to avoid contamination. Before inspection, wipe down the outer surface of the test sample container with a cotton ball dipped in 70% isopropyl alcohol.

(10) Any items containing living organisms or bacteria must be disinfected before being washed in the sink to avoid contamination of the pipes.

 

Specification

Model item
ISO 7 CLEAN ROOM
AL-CS4*6/C7 
AL-CS5*10/C7
AL-CS6*12/C7
AL-CS7*20/C7
Size(mm)
4000*6000*2500
5000*10000*2500
6000*12000*2500  
7000*20000*2500
Material
Framework
Cold rolled steel /Aluminum/Stainless steel/sandwich panel
Around
Plexiglass,Soft curtain,Anti-static strip curtain/sandwich panel
Clean Class Level
10000
10000
10000
10000
HEPA filter
Size(mm)
610*610*69
1220*610*69
1220*610*69
1220*610*69
Efficiency(%)
99.99
99.99

 

99.99
99.99
Air flow (m3/h)
3600
7500
10800
21000
Pre filter
Size(mm)
Optional
Motor Spec
Power supply
220V/50Hz
220V/50Hz
220V/50Hz
220V/50Hz
Noise(dB)
62
63
62
63

 

Sterile Cleanrooms and Air Showers

 

Air showers are an essential part of any modern cleanroom solution. The purpose of an air shower is to clean away surface contaminants from any human or object that will enter a clean area. Air showers also serve as a buffer zone between clean and non-clean areas and areas of varying cleanliness levels. Air showers are frequently seen facilities that manufacture food and beverage products, pharmaceutics, medical instruments, and electronics.

 

Air showers are generally classified as either “general" or "interlocking", where general air showers are manually operated and interlocking air showers are fully automatic. Interlocking air showers eliminate the risk of personnel skipping the air shower when entering the cleanroom, and are thus the recommended choice for nearly all operations. The biggest risk of contamination is generally cleanroom personnel themselves. Therefore, air showers are a vital component for any cleanroom system design

 

 

Sterile Cleanroom Cleanliness Levels:

 

 

What We Can Do For You?

 

Front end consultancy support, Concept design and engineering.

 

Clean room design and construction.

 

Unique range of clean room modular walls and ceilings, flooring system.

 

Cleanroom accessories (pass boxes, step over benches, change room furniture and fittings, sampling and dispensing booths, air showers, etc.) GRP clean room doors.

 

Equipment selection ,Validation master plans, protocols and continuous monitoring systems regulatory advise.

 

HVAC Design and Installation.

 

Hot Products

Best Sold 10*20meters stainless steel clean room with aluminum profile Main Features: 200 square ...
Pharmaceutical Sterile Clean Room with GMP standard Important Considerations for Operating a Sterile ...
Dust-Free Cleanroom Workshop Modular Cleanroom with Different Clean Classes Clean room is a special ...
Class 10000 Air Locked Air Clean Room for Food Packing Line Clean room is a special designed room to ...
ISO standard Sandwich Panels Clean Room, ISO 7 Modular Cleanroom Cleanrooms are essential to any ...
No dust prefabricated portable clean room with easy clean panels Clean Room is a special designed ...