TKC-K series dismountable current sensor is a open loop device based on the measuring principle of the hall effect. It can measure DC,AC pulse and various irregular wave current in electrical isolation conditions.

 

Electrical data

 

 

Type

 

Parameter

TKC

400K

TKC

600K

TKC

800K

TKC

1000K

TKC

1200K

TKC

1600K

TKC

2000K

TKC

2500K

TKC

3000K

 

Unit

 

Rated current(Ipn)

±400±600±800±1000±1200±1600±2000±2500±3000A

 

Measuring range(Ip)

±800±1200±1600±2000±2400±3000±3000±4000±4500A

 

Rated output

@Ip=±Ipn ±4±1%V

 

Supply voltage

±15±5%V

 

Power Consumption

+25,-10mA

 

Offset voltage

@Ip=0 ±20mV

 

Magnetic offset

@Ip=±Ipn-0 ±30mV

 

Offset drift

@ -40~+85℃ ≤±0.5mV/℃

output drift
@ -40~+85℃ ≤±0.5mV/℃

 

Linearity

@Ip=0-±Ipn ≤1%FS

 

Response time

@50A/μS, 10%-90% ≤7μS

 

Bandwidth

@ -3db DC….25KHz

 

Galvanic isolation

@ 50HZ,AC,1min 6KV
 

Applications

Variable speed drives

Welding machine

Battery supplied applications

Uninterruptible Power Supplies (UPS)

Electrochemical

 

Mechanical dimension(for reference only)

Remarks:

1. All dimensions are in mm.

2. General tolerance ±1mm.

 

Directions for use

 

When the current will be measured goes through a sensor, the current will be measured at the output end.

(Note: The false wiring may result in the damage of the sensor)

The output amplitude of the sensor can be adjusted according to users’ requirements.

Custom design in the different rated input current and the output current are available.

Standards

  • UL94-V0.
  • EN60947-1:2004
  • IEC60950-1:2001
  • EN50178:1998
  • SJ 20790-2000

General date

 

 ValueUnitSymbol
Operating temperature-40 to +85ºCTA
Storage temperature-40 to +125ºCTS
Mass(approx)417gM

 

Characteristics chart

Pulse current signal response characteristic      Effects of impulse noise

Hot Products

Measuring Hall Effect Based Current Sensor , Hall Effect Ac Current Sensor TKC-H TKC-H series is a ...
DC 500V 1000MΩ Open Loop Hall Effect Current Sensor Accuracy ±1% TKC-HAXseries current sensor is a ...
High Sensitivity Hall Effect Sensor Non Contact Current Sensor Ta=25℃±5℃ The TKC-BR series open loop ...
TKC-BS/BR Open Loop Hall Effect Current Sensor Pulsed Currents Measurement TKC-BS/BR series current ...
Dismountable Hall Effect Current Transformer Measure DC AC Pulse Current TKC-K series dismountable ...
Blue Hall Effect Current Sensor Transducer , Hall Effect Dc Current Transducer The TKC-BSR565 series ...