Home Products Security & Protection Roadway Safety

gx53 lamp cap gauge

Refine Search
Results forgx53 lamp cap gaugefrom 4669 Products.
Test Gauges for Lamp Caps and Holders HDJ0001 Standard: IEC 60598-1: Luminaires - Part 1:General requirements and tests; IEC 60061-3: Lamp caps and holders together with gauges for ...
Shanghai, china
Member
B22 Go No Go Gauge of Finished Lamp Caps Include: 1) IEC60061-3 7006-11-8 B22 Go Gauges for Caps on Finished Lamps; Purpose: To check dimensions A max., N min. D1 min., D1 max., ...
Guangdong, china
Member
B15 Go No Go Gauge of Finished Lamp Caps Include: 1) IEC60061-3 7006-11-8 B15 Go Gauges for Caps on Finished Lamps; Purpose: To check dimensions A max., N min. D1 min., D1 max., ...
Guangdong, china
Member
Not go gauge for caps on finished lamps E17, 7006-28F-1 Purpose: To check the minimum outside (major) diameter of the screw thread, dimension d, of E12 caps on finished lamps. ...
Guangdong, china
Member
Go gauge for caps on finished lamps E12, 7006-27H-1 Purpose: To check the maximum dimensions of the screw thread and dimension T1 minimum of E12 caps on finished lamps. Testing: ...
Guangdong, china
Member
Go gauge for caps on finished lamps E17, 7006-27K-1 Purpose: To check the maximum dimensions of the screw thread and dimension T1 minimum of E17 caps on finished lamps. Testing: ...
Guangdong, china
Member
Go gauge for E14 caps on finished lamps, 7006-27F-1 Purpose: To check the maximum dimensions of the screw thread and dimension T1 minimum of E14 caps on finished lamps. Testing: ...
Guangdong, china
Member
Not go gauges for caps on finished lamps B22, 7006-10-8 According to standard IEC 60061-3 Purpose: To check dimension A in, of caps B22 on finished lamps. Testing: Caps on finished ...
Guangdong, china
Member
Go gauge for caps on finished lamps E12, 7006-27H-1 Purpose: To check the maximum dimensions of the screw thread and dimension T1 minimum of E12 caps on finished lamps. Testing: ...
Guangdong, china
Member
The sharp part of the edge of the thread shall be broken with a radius of 0.2 mm to 0.3 mm. PURPOSE: To check the maximun dimensions of the crew thread and dimension T1 min, of E39 ...
Guangdong, china
Member
Go gauge for caps on finished lamps E40, 7006-27-7 Purpose: To check the maximum dimensions of the screw thread and dimension T1 minimum of E40 caps on finished lamps. Testing: ...
Guangdong, china
Member
Go gauges for caps E26, E26/50x39, E26/51x39 & E26d, 7006-27D-3; Purpose: To check the maximum dimensions of the screw thread and dimension T1 minimum of E26, E26/50x39, E26/51x39 ...
Guangdong, china
Member
Not go gauges for caps on finished lamps B22, 7006-10-8 According to standard IEC 60061-3 Purpose: To check dimension A in, of caps B22 on finished lamps. Testing: Caps on finished ...
Guangdong, china
Member
Not go gauges for caps on finished lamps B15, 7006-10-8 According to standard IEC 60061-3 Purpose: To check dimension A in, of caps B15 on finished lamps. Testing: Caps on finished ...
Guangdong, china
Member
The drawing is intended only to illustrate the essential dimensions of the gauge. For details of cap E39, see sheet 7004-24A. PURPOSE: To check the minimum outside (major) diameter ...
Guangdong, china
Member
Go gauges for caps on finished lamps BA9, B15, BA15 & B22, 7006-11-8. According to standard IEC 60061-3 Purpose: To check dimensions A max., N min. D1 min., D1 max., and the ...
Guangdong, china
Member
Purpose: To check the minimum outside (major) diameter of the screw thread, dimension "d" of E27 caps on finished lamps shown on sheet 7006-21. Testing: When the gauge is placed ...
Guangdong, china
Member
Go and not go gauge for unmounted bi-pin cap(not for use on finished lamps) G13, 7006-44-4 Purpose: To check dimensions E min., E max., F min., G max., H max. and the combined pin ...
Guangdong, china
Member
Go gauge for dimension "S1" of E27 caps on finished lamps, code 7006-27C-1 Purpose: To check the dimension S1 minimum and S1 maximum of E27 caps on finished lamps shown on sheet ...
Guangdong, china
Member
Purpose: To check dimensions A max., N min. D1 min., D1 max., and the diametrical position of the pins of caps B15 on finished lamps. Testing: The cap shall enter the gauge until ...
Guangdong, china
Member
Page 8 of 50 |< << 4 5 6 7 8 9 10 11 12 >> >|