Home Companies Suzhou Ephood Automation Equipment Co., Ltd.

67DFR Model Fisher Pressure Reducing Regulator For Reducing Pressure

Suzhou Ephood Automation Equipment Co., Ltd.

Contact Us

[China] country

Trade Verify

Address: Plant NO.1,No.28,YinzhuRoad,New District,Suzhou,Jiangsu,China

Contact name:Barry Wang

Inquir Now

Suzhou Ephood Automation Equipment Co., Ltd.

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

67DFR Model Fisher Pressure Reducing Regulator For Reducing Pressure

Country/Region china
City & Province suzhou jiangsu
InquireNow

Product Details

Fisher 67DFR Instrument Supply Filter Regulator

Fisher 67DFR Filter Regulator has a filter and internal relief valve with a soft seat for reliable shutoff with no discernible leakage.

 

Fisher 67DFR model of regulators are typically used to deliver constant reduced pressure of gaseous fluids to pilot-operated
controllers and other pneumatic instrumentation. As shown in the Available Configurations table, an assortment of regulators
is available to meet diverse flow requirements.

 

Available Configurations
 

 

Connection Size1/2" NPT
Maximum Inlet Pressure250 psig / 17.2 bar
Spring Range0-125 psi/ 0-8.6bar
Pressure RegistrationInternal
Smart Bleed Check Valve Set point6 psi / 0.41 bar differential

 

Temperature Capabilities
With Nitrile (NBR):
Standard Bolting: -20 to 180°F / -29 to 82°C
With Gauges: -40 to 180°F / -40 to 82°C

Fisher 67CFR Internal Relief Performance

Low capacity for minor seat leakage only; other overpressure protection must be provided if inlet pressure can exceed the maximum pressure rating of downstream equipment or exceeds maximum outlet pressure rating of the regulator.

Smart Bleed Check Valve Set point

6 psi / 0.41 bar differential

Fisher 67CFR Filter Regulator : Filter Capabilities

Free Area: 12 times pipe area

Micron Rating: Polyethylene Filter (Standard): 5 microns Glass Fiber Filter (Optional): 5 microns PVDF or Stainless Steel Filter (Optional): 40 microns

Drain Valve and Spring Case Vent Location

Aligned with inlet standard, other positions optional

Principle of Operation

67CFR Filter Regulator Downstream pressure is registered internally on the lower side of the diaphragm. When the downstream pressure of Filter Regulator is at or above the set pressure, the valve plug is held against the orifi ce and there is no fl ow through the regulator. When demand increases, downstream pressure drops slightly allowing the spring to extend, moving the stem down and the valve plug away from the orifi ce. This allows fl ow through the regulator.

Internal Relief (Types 67CR, 67CSR, 67CFR, and 67CFSR)

If for some reason, outside of normal operating conditions, the downstream pressure exceeds the setpoint of the regulator, the force created by the downstream pressure will lift the diaphragm until the diaphragm is lifted off the relief seat. This allows flow through the token relief. The relief valve on the Type 67CR, 67CSR, 67CFR, or 67CFSR is an elastomer plug that prevents leakage of air from the downstream to atmosphere during normal operation, thereby conserving plant air.

 

Smart Bleed Airset

In some cases, it is desired to exhaust downstream pressure if inlet pressure is lost or drops below the setpoint of the regulator. For example, if the regulator is installed on equipment that at times has no flow demand but is expected to backflow on loss of inlet pressure. The Types 67CFR and 67CFSR can be ordered with the Smart Bleed option which includes an internal check valve for this application. During operation, if inlet pressure is lost, or decreases below the setpoint of the regulator, the downstream pressure will back flow upstream through the regulator and check valve. This option eliminates the need for a fixed bleed downstream of the regulator, thereby conserving plant air.

Overpressure Protection

The 67C Series filter regulators have maximum outlet pressure ratings that are lower than their maximum inlet pressure ratings. A pressure relieving or pressure limiting device is needed if inlet pressure can exceed the maximum outlet pressure rating.

Types 67CR, 67CSR, 67CFR, and 67CFSR have a low capacity internal relief valve for minor seat leakage only. Other overpressure protection must be provided if the maximum inlet pressure can exceed the maximum pressure rating of the downstream equipment or exceeds the maximum outlet pressure rating of the regulator.

 

 

 

Hot Products

Electric Heating Water Type Liquefied Petroleum Gas Vaporizer A compact, economical electrically ...
North American Tempest High Velocity Gas Burner The 4441 model Tempest has gained acclaim for its ...
YOKOGAWA EJA110E Differential Pressure Transmitter The high performance differential pressure ...
Fisher 67DFR Instrument Supply Filter Regulator Fisher 67DFR Filter Regulator has a filter and ...
67CFSR Stainless Steel Body Material Fisher Instrument Supply Filter Regulator Fisher 67CFR : filter ...