The steam generator adopts automatic microcomputer control system, automatic control of equipment operation, no manual guard, automatic water intake system. Automatic pressure control system, automatic feeding system. With a low water level alarm and stop operation, overpressure alarm to stop the whole system, lower than the set pressure automatically start operation, reach the required maximum pressure automatically stop operation, using multiple safety design, safe and reliable. Factory configuration is complete, durable, safe and convenient. Fire tube arrangement structure, heating surface is large, temperature rise and steam production is fast. After combustion, the flue gas return cycle, the flue gas heat exchange is full, the exhaust smoke temperature is low, the water supply two stages of heat exchange, efficient energy saving and environmental protection. Packaged factory, fast installation, simple operation, easy maintenance, safe, stable and reliable operation and low operating cost.
1. One-click operation is safe and convenient
Configuration of microcomputer LCD control system, one-click
operation, the water and electricity installation in place, set the
automatic stop of high pressure and automatic start of the
operation of low pressure, press the switch key, the generator will
enter the automatic operation state, safe and simple, no
professional furnace personnel, reduce the labor intensity of
personnel.
2. Multi-protection security guarantee
The product is equipped with high quality pressure controller,
safety valve, and multiple protection such as overpressure alarm,
low water level alarm and overheating protection to ensure product
quality and safety.
Model |
Rated Capacity (t/h) |
Rated Pressure (Mpa) |
Rated Temperature (C) |
Maximum transport weight of boiler(t) |
Maximum transport size of boiler( mm) | Fuel Consumption | ||
diesel oil (Kg/h) |
Natural gas (m³/h) |
LPG (kg/h) | ||||||
LHS0.05 | 0.05 |
0.4 |
151 | 0.37 | 700× 650×1700 | 8.2 | 10.2 | 6.45 |
LHS0.1 | 0.1 | 0.59 | 800×750 ×2000 | 11.3 | 13.6 | 13 | ||
LHS0.2 | 0.2 |
0.4~0.7 |
151~170 | 0.68 | 900× 850×2000 | 15.6 | 18.7 | 19.4 |
LHS0.3 | 0.3 | 0.83 | 1000×950×2000 | 22.5 | 26.8 | 25.6 | ||
LHS0.5 |
0.5 |
1.07 |
1100×1050×2000 |
32.5 |
36.8 |
32 | ||
LHS0.7 |
0.7 |
0.4~0.7 |
151~170 |
1.45 |
1200×1150×2200 |
40.6 |
48.5 |
50 |
LHS1 |
1 |
1.78 |
1300×1250×2450 |
45.9 |
65.3 |
65 | ||
LHS1.5 | 1.5 |
1.9 |
1780×1600×3200 |
78.4 |
102.1 |
97 | ||
LHS2 |
2 |
5.2 |
2000×2000×4000 |
91.8 |
130.6 |
130 | ||
Note: 1,Fuel type:Light diesel oil/Heavy oil/Natural gas/Liquefied gas/City gas 2 ,Parameter is for reference only, we can design the boilers based on customers’ needs. |