Home Companies Wuhan Weiruo Communication Tech. Co.,Ltd

1*2 4 8 16 32 64 SM 0.9mm SC APC Connector Fiber Optic PLC Splitter

Wuhan Weiruo Communication Tech. Co.,Ltd
Active Member

Contact Us

[China] country

Address: No.8, Optoelectronic park street No.2, Zuoling, Hongshan district, Wuhan, Hubei province, China.

Contact name:Geng

Inquir Now

Wuhan Weiruo Communication Tech. Co.,Ltd

1*2 4 8 16 32 64 SM 0.9mm SC APC Connector Fiber Optic PLC Splitter

Country/Region china
City & Province wuhan hubei
Categories Radio & TV Broadcasting Equipment
InquireNow

Product Details

1*2 4 8 16 32 64 SM 0.9mm plc fiber optic plc splitter with SC/APC connector

Features of  1*2 4 8 16 32 64 SM 0.9mm plc fiber optic plc splitter with SC/APC connector

*Good uniformity and low insertion loss
*Low polarization dependent loss
*Excellent environmental stability
*Excellent mechanical construction
*Compact design, suitable for installation in optical equipment
*Wide operating temperature:-40~85 ℃
*High reliability and stability

 
Application of 1*2 4 8 16 32 64 SM 0.9mm plc fiber optic plc splitter with SC/APC connector

Optical Signal Distribution

Data Communications

Lan and CATV System

FTTX Deployment

Passive Optical Networks (PON)

Measuring System and Laser System

 
Product Paramenters of 1 Input 8 Output 1x8 Steel Tube Fiber Optic Splitter with SC APC Connector
Parameters1×21×41×81×161×321×642×22×42×82×162×32
Operating Wavelength (nm)1260~16501260~1650
Fiber TypeG657 or customizedG657 or customized
Insertion Loss (dB)≤4.1≤7.4≤10.5≤13.8≤17.1≤20.4≤4.2≤7.6≤11≤14.5≤17.5
Loss Uniformity (dB)≤0.8≤0.8≤0.8≤1.0≤1.5≤2.0≤0.8≤1.5≤1.5≤2≤2.5
Return Loss (dB)≥50≥50≥50≥50≥50≥50≥50≥50≥50≥50≥50
Polarization Dependent Loss(dB)0.20.20.30.30.30.40.20.20.30.40.4
Directivity (dB)≥55≥55≥55≥55≥55≥55≥55≥55≥55≥55≥55
Temperature Stability (-40~85 ℃)(dB)0.50.50.50.50.50.50.30.50.50.50.5
Operating Temperature (℃)-40~85-40~85
Storage Temperature (℃)-40~85-40~85
Note:
1. The insertion loss is at least 0.2dB less without connector.
2. The insertion loss for 2×N PLC would increase less than 0.3dB.
3. Insertion loss varies with different connectors:UPC ≥50 dB, APC ≥55 dB

 

More Types

Details:

 

 

You may also like:

 
 
 
 

Hot Products

FTTH 1x2 1x4 1x8 1x16 Fiber Optic SC/UPC APC Fiber PLC Splitter Box Planar optical waveguide ...
1*8 ABS coupler fiber optic plc splitter 2.0mm cable and Plug-in type SC APC PC UPC connector ...
1*8 Optical Splitter SCUPC APC Fiber PLC Splitter Box With Insert Type Description of 1*8 Optical ...
1 Input 8 Output 1x8 Steel Tube Fiber Optic Splitter with SC APC Connector Description of 1 Input 8 ...
1*2 4 8 16 32 64 SM 0.9mm plc fiber optic plc splitter with SC/APC connector Features of 1*2 4 8 16 ...
FTTH Equipment 1x12 PLC Splitter Optical Fiber With SC/APC Connector FTTH Cassette Description : PLC ...