KSULR-100 Universal LORA RTU

Instruction manual

 

1.Introduction

KSULR-100 universal LORA RTU is a multifunctional sensor data acquisition box launched by our company for smart industry, smart agriculture and smart community. It adopts the LoRaWAN standard protocol, has SPI, UART, ADC, GPIO, I2C and other communication interfaces and multiple input interfaces, and the configuration is flexible. The best choice to solve the fragmentation of LoRa iot application is to connect different sensors conveniently and quickly, shorten the sensor docking cycle and research and development cost, and quickly realize the networking and scale of sensors. The built-in wireless module uses the network to provide users with wireless long-distance and low-power data transmission, and sends all status data of sensors to the cloud background management server in real time to realize data statistical analysis of the intelligent cloud platform.

2.Picture

 

3.Feature

  • Support standard LoRaWAN protocol;
  • Support a variety of frequency bands at home and abroad, such as: CN470-510/EU863-870/US902-928/ AS923-925 / AU915-928 /CT850;
  • Integrated SPI, UART, ADC, GPIO, I2C and other communication interfaces, can be widely connected to a variety of types of sensors;
  • It adopts low-power consumption design, and provides two modes of external power supply and battery power supply for selection;
  • The battery power supply mode adopts 19000mAH large-capacity battery;
  • Support a variety of voltage output, such as: 3.3V, 5V, 9V, 12V, etc;
  • Support wired and wireless parameter configuration and firmware upgrade,Support remote configuration;
  • Support low battery alarm;
  • Support heartbeat package reporting, heartbeat interval can be configured;
  • Industrial temperature range -40°C~+80°C.

4.apply

KSULR-100 universal LORA RTU series is used to collect the values of various sensors at the installation point, and upload the real-time data to the centralized management platform through the built-in wireless transmission module, which is convenient for users to intelligent centralized management, simple installation and convenient maintenance. Can be flexible in the pole, lamp pole, building inside and outside the wall, the roof of the pole, wall hanging way installation. It is suitable for monitoring sensors in docking plants, warehouses, agricultural greenhouses, computer rooms, hydrology and other scenarios (e.g. Water pressure sensor, liquid level sensor, liquid flow sensor, water immersion sensor, temperature sensor, humidity sensor, light sensor, PM2.5, Angle sensor, wind speed sensor, etc.), achieve unified access, unified data collection, and flexible expansion ability.

5.Technical parameters

projectPerformance indicators
Wireless performanceData transfer rate300bps~5.4Kbps
Operating frequencyCN470~510MHz
EU863~870MHz
US902~928MHz
AS923~925MHz
AU915~928MHz
CT850MHz
Maximum transmit power19dBm
Maximum link budget167dB
Maximum reception sensitivity-140dBm(SF=12)
LoRa antennaExternal omnidirectional antenna
Communication interfaceUART,SPI,I2C,GPIO,ADC,RS485
Working environmentOperating temperature-40℃~+85℃
Operating humidity10%~95%RH (non-condensing)
Power supplyPower supply modeDC 5~24V input & built-in battery (optional).
Battery capacity3.6 V/19000mAH
powerSleep current≤6uA
Transmit current≤125mA
Receive current≤16mA

6.Parameter settings

The parameters can be set on demand according to the factory instructions, and can be used after receiving the redirection LoRaWAN base station

6.1 KSULR-100 General LORA RTU parameter setting

KSULR-100 universal LORA RTU is connected to set parameters through USB-TTL cable (purchased by yourself). After removing the soft plug on the back of the acquisition box with tweezer and removing the screw, the shell is opened and connected as shown (RXD and TXD cross connect, that is, RXD of the USB-TTL cable is connected to TXD of the acquisition box, TXD is connected to RXD of the acquisition box, and TXD is connected to RXD of the acquisition box. The VCC is shorted to the 3V3 with the shorting cap, and the GND is connected to the GND of the acquisition box)

 

6.1.1 Enable motherboard 485 function

open the sensorbox configuration tool > Select the corresponding com> Baud rate 9600> Click Open to open the serial port > Click AN201>Function Select> Input c in the box after AT+FUNMODE= and then click AT+FUNMODE= OK appears at the bottom left to indicate completion

 

 

 

 

6.1.2 Modify the baud rate of the sensor communication interface

Click on the box after UART>AT+UART1CFG, enter 9600> and then select 8n1. Click on OK below AT+UART1CFG to indicate completion

 

 

6.2 Set the sensor query parameters and query time

(The factory defaults to collect data every 30 minutes, and the increase in query frequency will increase power consumption).

Click AN201> Click RS485> Click AT+TRANS485MODE= rear inverted triangle select polling> click AT+TRANS485MODE= set parameters, ok> Enter 1800 in the box after AT+SAMPLEDATATIM= > Click on AT+SAMPLEDATATIM= Set parameters, ok> Enter 8 in the box after AT+REQDATA= > Enter 0103010000030437 in the box after 8> Click AT+REQDATA= set parameters, ok> AT+RESPONSETIM= input 10000 in the box after AT+RESPONSETIM= (Power supply time for sensor during each query, too short may lead to failure to obtain correct data)> Click AT+ responsetim = set parameters, ok> click AT+REBOOT appears in the bottom left. After the buzzer sounds three times, it means that the network is successfully entered, and the data can be viewed in the background.

 

 

6.3 Redirect the LoRaWAN base station

In order for the LoRaWAN base station's packets to be sent to the specified LoRa Server, it is necessary to configure the Server address for the base station.

 

Open the Chrome browser, input the LoRaWAN base station IP (192.168.10.99 for this example), then input the user name and password (user name =guest, password =rimelink for this example), and enter the web configuration page as shown below.

 

 

Then click LoRaWAN Server Configuration > Server Address > enter the IP (lorawan.timeddd.com /b19>) > OK. As shown in the figure below

6.4 Log in to the background to view data

Log on to http://lorawan.timeddd.com/unit/ULogin.aspx,

account number: 19240527

password: admin @ 666666

 

After logging in, click the data option of the corresponding ID device to view the corresponding data, and the factory set to send data every 30 minutes

 

 

The ID location is shown in the figure

The data obtained are as follows (in hexadecimal), the distance unit is 0.1mm below 6 m, the range unit is mm above 6 m, and the temperature unit is ° C. The 90th byte is the liquid level value, and the 11th byte is the temperature value. In this case, the liquid level value is 08E3, the unit is mm, and the temperature value is 001B. When converted to decimal number, the sensor measures the liquid level to 2275mm and the temperature to 27℃.

 

 

7.KSULR-100 Universal LORA RTU is wired to the sensor

KSULR-100 universal LORA RTU are all 485 outgoing, which can be connected to the label on the sensor according to the acquisition box.

7.1 Installation

7.1.1 Precautions

In order to avoid equipment damage caused by improper installation and construction, please follow the following precautions:

  • The installation of equipment can only be carried out by professional personnel or authorized engineering representatives;
  • In order to ensure the personal safety of construction personnel, please use professional and qualified installation tools;
  • Equipment installation location must be away from fire, strong electric field and other environment, otherwise it may cause damage to the equipment;
  • It is forbidden to install the equipment in high vibration environment;
  • Equipment outdoor installation needs to install water proof tank;
  • The company reserves the final right to interpret the installation precautions.

7.1.2 Prepare the installation tool

Installation tools are not provided for equipment installation. Please prepare the following installation tools according to the actual installation environment

7.1.3 Equipment indoor installation

Wall-mounted installation

First, place the multi-function box flat on the wall installation position, and use a marker to mark the installation hole. Secondly, the percussion drill (drill bit is 8mm) is used to punch holes in the wall marking position, and the rubber sleeve is put into the hole again. The hammer is used to strike the rubber sleeve, so that the rubber sleeve is all into the installation hole. Finally, the screw with a spacer is used to fix the multifunctional box on the wall.

 

 

 

Pole mounting method

First, use the fixing screws to fix the backplane to the back of the multi-function box, and secondly, use the hoop to pass through the backplane hole on the back of the multi-function box;Wrap the hoop around the post again, finally use a small screwdriver to lock the hoop tightly and the installation is complete.

7.1.4 Outdoor installation of equipment

Description of the data communication format

FportUP/DOWNPayload  Description/Comments
Sensor typeFrame typedata format
43UP0x040x01ADC

3 bytes:

The first byte battery voltage, the highest bit is 0 for normal voltage, 1 for low voltage, the lower 7 bits for voltage value, the actual value needs to be divided by 10, such as 0x21 for 3.3V, normal voltage, 0x9F for 3.1V, low voltage;

The 2-3 bytes of ADC data take up 2 bytes, and the reported value should be divided by 1000, such as 0xce4 for 3.3V

43UP0x040x02IIC

N+1 bytes:

The first byte battery voltage, the highest bit is 0 for normal voltage, 1 for low voltage, the lower 7 bits for voltage value, the actual value needs to be divided by 10, such as 0x21 for 3.3V, normal voltage, 0x9F for 3.1V, low voltage;

2-N+1 byte IIC data

N bytes are the same as the number of configured read registers

43UP0x040x03RS485

N+1 bytes

The first byte battery voltage, the highest bit is 0 for normal voltage, 1 for low voltage, the lower 7 bits for voltage value, the actual value needs to be divided by 10, such as 0x21 for 3.3V, normal voltage, 0x9F for 3.1V, low voltage;

The 2-N+1 byte RS485 data is consistent with the data sent to the device by the sensor

43UP0x040x04temperature

3 bytes:

The first byte battery voltage, the highest bit is 0 for normal voltage, 1 for low voltage, the lower 7 bits for voltage value, the actual value needs to be divided by 10, such as 0x21 for 3.3V, normal voltage, 0x9F for 3.1V, low voltage;

2-3 bytes temperature data

The highest bit of the two bytes, 0: normal, 1: alarm; The lowest 15-bit signed integer, the highest byte first, the actual value must be divided by 100, (for example, 97E6 indicates alarm, the temperature is 61.18 ° C, or 6FED indicates no alarm. Temperature is -41.15 ° C)

 

 

7.2 Storage and Transportation

1, the product should be stored in -40℃~+80℃, relative humidity is not more than 90%, ventilated, dry, no corrosive gas warehouse.

The product is packed in one package with the certificate and the instruction manual. Strong collision is strictly prohibited during transportation

7.3 Warranty terms

Users in strict accordance with the instructions, the correct wiring, installation, maintenance of the case, this product free warranty for 1 year.

The following circumstances are not covered by the warranty:

1. Disassemble the circuit board and its components;

2. lightning or strong electricity into the system, burned out the circuit;

3. the power supply voltage exceeds the limit value, the circuit board is burned out;

4. electrical box water or other foreign bodies;

5. Incorrect selection, exceeding the scope of use of the product;

6. A certain part of the sensor or the whole machine is injured or damaged.

 

Hot Products

KSULR-100 Universal LORA RTU Instruction manual 1.Introduction KSULR-100 universal LORA RTU is a ...
KSULR-100 Universal LORA RTU Instruction manual 1.Introduction KSULR-100 universal LORA RTU is a ...
LoRa Gateway 1.Introduction LoRa is a wireless spread spectrum communication technology, and LoRaWAN ...
KFOIMUH Inertial Navigation System Specification Product Description: KFOIMUH series inertial ...
KFOIMUm Inertial Navigation System Specification Product Description: KFOIMUm series inertial ...
KFOIMUm Inertial Navigation System Specification Product Description: KFOIMUm series inertial ...