Foc Communication CO.,LTD |
|
Fiber PLC Splitter Cassette Type SC / APC , 1×16 Guaranteed Performance Specification and High Reliability
PLC splitters are based on planar lightwave circuit technology and
high precision alignment. PLC splitters can split or combine light
from one or two fibers into multi outgoing fibers uniformly over a
wide spectral range with ultra-low insertion loss and low
polarization dependent loss. PLC splitters are highly compact and
offer excellent optical performance with high reliability. These
splitters are fully compliant with Telcordia GR-1209/1221 and are
guaranteed for performance in harsh environments.We currently offer
configurations up to 2 x 64 in both individual parts and module
versions.
Cassette type: installed in 19 inch standard rack; in fiber branch
home, installation device is provided in the optical fiber cable
transfer box; branch home, installed customer specified equipment.
Features
Low insertion loss
High maximum power tolerance
Excellent splitting uniformity
Broadband Operating wavelength
Compact design
Low polarization independent
Applications
PON- FTTX Networks
CATV
Outside Plant Equipments
DWDM and CWDM systems
Optical Specifications
Parameter | Unit | Specification (P Grade) | |||||
Channel Number | 1X2 | 1X4 | 1X8 | 1X16 | 1X32 | 1X64 | |
Operation Wavelength | nm | 1260~1650 | |||||
Insertion Loss (Max.) | dB | 4.3 | 7.4 | 10.7 | 13.9 | 17.2 | 21.5 |
Uniformity (Max.) | dB | 0.5 | 0.8 | 1.0 | 1.4 | 1.6 | 2.0 |
Polarization Dependent Loss | dB | 0.2 | 0.3 | 0.3 | 0.3 | 0.3 | 0.5 |
Return Loss | dB | ≥50 | |||||
Directivity | dB | ≥50 | |||||
Operating Temperature | ℃ | -40~+85 | |||||
Storage Temperature | ℃ | -40~+85 |
Parameter | Unit | Specification (P Grade) | |||||
Channel Number | 2X2 | 2X4 | 2X8 | 2X16 | 2X32 | 2X64 | |
Operation Wavelength | nm | 1260~1650 | |||||
Insertion Loss (Max.) | dB | 4.3 | 7.6 | 11.0 | 14.8 | 17.9 | 21.5 |
Uniformity (Max.) | dB | 0.8 | 1.0 | 1.2 | 1.5 | 1.8 | 2.0 |
Polarization Dependent Loss | dB | 0.2 | 0.3 | 0.3 | 0.3 | 0.3 | 0.5 |
Return Loss | dB | ≥50 | |||||
Directivity | dB | ≥50 | |||||
Operating Temperature | ℃ | -40~+85 | |||||
Storage Temperature | ℃ | -40~+85 |
Note: All the data above does not include connectors.
Ordering Information
PLC |
|
|
|
|
|
|
| Port | Fiber Type | Input | Output | Pigtail Length | Connector |
| 0102=1x2 | 1=G652D, 2=G657A | L=900µm Loose tube, S=2.0mm, R=3.0mm, 0=Adapter | L=900µm Loose tube, S=2.0mm, R=3.0mm, 0=Adapter | 05-20=0.5-2.0m, 0=Adapter, X=Others | FU=FC/UPC, FA=FC/APC, SU=SC/UPC, SA=SC/APC, ST=ST/UPC, LU=LC/UPC,
LA=LC/APC, 00=None, X=Others |