flexible fume extraction arm
SHP50-2-Lab Fume Extractor/Exhaust,50MM diameter fume extraction arm,fume exhaust
 

SHP50-2-Lab Fume Extractor/Exhaust,50MM diameter fume extraction arm,fume exhaust

Item no.:SHP50-2
Product name:Fume exhaust (ceiling/wall/bench mounted)
Material:PP(Polypropylene),PVC(Polyvinyl chloride)
1. Joint: high grade PP/PC, to be 360 swiveled
2. Joint hermetic ring: low-aging treated rubber.
3. Support spring/joint bolt: High grade PP with a moded – in S/S bearing locking center bolt
4. Adjustable joint knob: high grade PP/PC with a built-in brass nut locking with center bolt
5. Damper: to manually adjust airflow by a knob
6. Dome/cup hood: D210mm, high grade PP/PC, red, grey & transparent available
7. Extension tube: D50mm PVC/PC
8. Bracket: high grade PP/PC (ceiling/wall mounted), PP/PC (bench mounted)
9.Guiding ting: Low – friction treated rubber

 

 

Fume extraction,fume extractors,fume exhaust,fume exhausters,extraction fan,extraction hood,exhaust cowl,fume suction,gaseous waste exhaust,gas exhaust,waste gas cowl

Lab Fume Hoods valves,Lab water gas Faucets,Lab air taps,Lab fume exhaust,Fume extractor,Lab PP sink,Lab drying rack,Lab drainage pegboard,Pegboards & drip trays,Epoxy Pegboard Glassware Drying Rack,

 

 

Jiont:High grade PP.to be 360°swiveled,easy to dismantle, assemble &clean
Sealing ring: Low-friction treated rubber
Center bolt:304stainless steel
Adjustable joint knob: Totally brass with a s/s bearing inside locked with center bolt
Damper:To adjust air flow with a knob manually
Dome/cup hood: High grade PP/PC
Tube:75mm /PP
Swing device: with 360°swing device,take fixed rack as centre, max enabing
movement radius to 1600mm
Installation Bracket: Injection of plastics from a complete Mold,mounting panel
strongly connected to the joint

Jiont:High grade PP.to be 360°swiveled,easy to dismantle, assemble &clean
Sealing ring: Low-friction treated rubber
Center bolt:304stainless steel
Adjustable joint knob: Totally brass with a s/s bearing inside locked with center bolt
Damper:To adjust air flow with a knob manually
Dome/cup hood: High grade PP/PC
Tube:75mm /PP
Swing device: with 360°swing device,take fixed rack as centre, max enabing
movement radius to 1600mm
Installation Bracket: Injection of plastics from a complete Mold,mounting panel
strongly connected to the joint

 

1.Capability:

1)Made of PVC material, high grade PP, SUS304 stainless steel, corrosion-proof, acid-proof, and alkali-proof;

2)Movement scope is big, to be 360ºswiveled as center of bracket, 1240mm as radius; can be flexed freely inward the height scope of 720mm;

3)The distance between of ornamental bracket and bracket is adjustable; the adjustable scope is 990mm-1450mm.

4)The air adjustable knob can control the air flux;

5)It is convenient to use, easy to take down, recombine and clean.

 

2.Installation and using

1)Choose the installation position according to the work location and indoor environment, at the ceiling bore according to bracket, use M8 screw fasting the bracket to ceiling;

2)Put the flex tube into the pore of the drain wind tube, let tube sheath to lockup the flex tube and drain wind tube, to screw on the underpan;

3)Screw on the collect air cover;

4)Connect drain wind stomata to drain wind system;

5)When to use, can push and pull collect air cover, made it aim at pump down position, and adjust air flex adjustable knob. After using screw on adjustable knob, shut off baffle, fold collect air cover and reset.

 

3.Notice in application

1.Having the press axletree and the rubber loop, if the joint become flexible, can screw on joint knob;

2.Don’t overexertion when push and pull the collect air cover;

3.The angle of flex tube and bracket don’t exceed 90º, or else rebound;

4.Installation height: the distance of ceiling and collect air cover, Max. 2440mm, Min. 1710mm.

4.Sketch map of installation

 

Lab Furniture accessories & Lab Fittings:

 

Lab water gas Faucets,

 

Epoxy Pegboard Glassware Drying Rack,

 

Emergency shower & Safety eye wash:

 

pp centrifugal blowerceramic sink

Lab Fume Hoods valves,

 

Lab fume exhaust,

 

Pegboards & drip trays,

 

Drench shower

 

Eyewash station

 

Emergency shower

 

Lab PP sink,

 

Lab drying rack,

 

Lab drainage pegboard,

 

Safety shower

 

Safety eye wash

 

Face wash bath

 

Hot Products

SH712SCP-Dust Covered shower & eyewash station with bowl cover,SuS304 meets ANSI Z Item no.:SH712SCP ...
flexible fume extraction arm SHP50-2-Lab Fume Extractor/Exhaust,50MM diameter fume extraction arm...
flexible fume extraction arm SHP51-Lab welding dust smoke Fume Extractor/Exhaust arm,Aluminumalloy ...
flexible fume extraction arm SHP50-Lab Fume Extractor/Exhaust,Aluminumalloy flexible fume extraction ...
SHP83H-High temperature resistance Fume Extractor/Exhaust All aluminum alloy exhaust hood SHP83H...
SH650DH-Atomizing cooling spray blower fan Cooling dust removal odor removal anti-static SH650DH...