Explosion PD61 Series

 

  • Features:

Copper free aluminum, plastic-sprayed surface.

Ex d type flameproof enclosure.

Can be used as terminal box, distribution box and control box.

Degree of protection: IP66.

  • Application:

  • Technical Data:

Marking ATEX: Ⅱ 2 G Ex db ⅡB+H₂ T□ Gb 1)

                         Ⅱ 2 D Ex tb ⅢC T□ Db IP66

                          Note: See the technical data of EX-PD61-JX-IIB, 1) EX-PD61-ZM, EX-PD61-DL, EX-PD61-ZC-A, EX-PD61-LK, EX-PD61-QD

Marking IECEx: Ex db ⅡB+H₂ T□ Gb 1) 

                          Ex tb ⅢC T□ Db IP66

                          Note: See the technical data of EX-PD61-JX-IIB, 1) EX-PD61-ZM, EX-PD61-DL, EX-PD61-ZC-A, EX-PD61-LK, EX-PD61-QD

Marking UL1203: Class I, Division 1, Groups C, D

                            Class I, Division 2, Groups C, D

                            Class II, Division 1, Groups E, F, G

                            Class II, Division 2, Groups F, G

                            Class III

Standards: EN 60079-0, EN 60079-1,EN 60079-31, IEC 60079-0, IEC 60079-1, IEC 60079-31

Rated Voltage: Max.100V AC, 50/60Hz 

Rated Current: Max.1,200A

Ambient Temperature:-60℃ to + 60℃

Cable Entry :Standard M□×1.5 Plug, See the Specification Table

Entry Direction :Bottom

Cable Entry Device :Optional 

Type of Flameproof Joint :Cylindrical Joint, Threaded Joint, PlaneJoint

Installation Type :Wall Mounting(Standard); Bracket Mounting(Optional)

  • Technical Data

Built-in Components:Main switch: miniature circuit breaker(MCB) or molded case circuit breaker (MCCB)(Noted: earth leakage protection on

                                    request)

                                    Branch switch: miniature circuit breaker(MCB) or molded case circuit breaker (MCCB) (Noted: earth leakage protection on                                          request)

                                    Terminal Indicator light EX-D: Red, green, yellow, blue

                                    Button EX-A: Red, green, yellow

                                    AC contactor

                                    Thermal overload relay

                                    PLC programmer

                                    Soft starter

                                    Control switch EX-K

                                    Ammeter/Voltmeter

  • Ordering Guide

  • Dimensional Draings

  • Specification
Code Max Dissipated Power(W) Max Rated Current External Dimension Internal Dimension Mounting Dimension
T4/T130℃ T5/T95℃ T6/T80℃ A B C a b c d e f
EX-PD61-A 200 120 80 63A 250 200 170 192 142 131 180 130 10
EX-PD61-B 200 120 80 63A 300 200 170 242 142 131 230 130 10
EX-PD61-C 240 140 100 100A 350 200 170 292 142 131 280 130 10
EX-PD61-D 350 200 130 200A 350 300 270 290 240 229 280 230 12
EX-PD61-E 500 280 160 320A 450 350 280 378 278 233 365 265 12
EX-PD61-F 620 350 200 500A 560 450 280 488 328 225 475 315 14
EX-PD61-G 700 400 250 1000A 720 560 350 640 480 285 620 460 14
EX-PD61-H 800 500 350 1000A 980 720 375 880 620 290 820 560 18
  • EX-PD61 Distribution Equipment For Terminal Box Use

Suitable for terminal box of distribution system.

Note: 1.  The EX-PD61 terminal box wiring terminals have various arrangements methods.

          2.  It can be customized according to customer requirements and always meets the restrictions of the certificate. The maximum number of terminals and the maximum number of holes on the side meet the requirements of power dissipation and mechanical strength of the enclosure.

          3.  This table is for reference only.

          1).  Please specify the direction and size of each cable entry.

          2).  Cable entry is optional, and EX-QM-B(Ex d) or EX-QM-C(Ex d) is recommended.

  • IIIustration of EX-PD61 Distribution Equipment for Terminal Box Use
Cable Cross-sectional Area(mm)² Table for Max number of fitted terminal
Enclosure type number(Note: The enclosure type number is correspondent to the size. For example: A stands for the enclosure of 200x250)
A B C D E F G H
2.5(a) 20 28 36 72 100 140 270 264 396
4(b) 18 25 32 64 90 130 240 248 372
6(c) 15 21 28 56 80 100 210 200 300
10(d) 12 18 24 24 60 80 165 160 240
16(e) 9 15 20 20 25 70 135 136 204
35(f) - 5 5 10 15 24 64 90 135
70(g) - - - 5 10 18 25 72 -
120(h) - - - - 5 5 12 42 -
185(i) - - - - - 5 10 - -
240(j) - _ - - - 5 5 - -
300(k) - - - - - 5 5 - -
Terminal Arrangement (Number of terminal rows) 1 1 1 2 2 2 2 2 3
  • EX-PD61 Distribution Equipment for Control Box Use

Suitable for control unit distribution system

Note: 1. EX-A buttons, EX-D indicators, EX-K control switches, EX-B-A ammeters and EX-A-V voltmeters, etc. are included in EX-PD61 control boxes.

           2. The control box can be used for on-off operation of circuit,as well as the remote control or local control of the strat,stop,corotation and inversion of motor,When equipped with ammeter,it also can monitor the running of motor and circuit status.

            3. It can be customized in accordance with customer's requirements and conforms to the usage limits of conformity certificate. The number of cover components and the max. number of holes on the side can meet the requirements of dissipated power and enclosure mechanical strength.

  • Example Diagram for Control Box Use

  • EX-PD61 Distribution Equipment for Distribution Box Use

Suitable for power unit of distribution system

Note: 1.MCB (Miniature Circuit Breaker)or MCCB(Moulded Case Circuit Breaker),AC contactor thermal overload relay,PLC programmer,soft starter,EX-A pushbuttons.EX-D indication, EX-K control switches,EX-B-A ammeters and EX-A-V voltmeters etc.are included in the box.

           2. The control box can be used for power distribution or on-off operation of the circuit, as well as the control of the start, stop, corotation and inversion of motor and provide comprehensive protection for motor. It can be set up for two-site control or multi-site control.

            3. It can be customized in accordance with customer's requirements and conforms to the usage limits of conformity certificate. The number of cover components and max. number of holes on the side can meet the requirements of dissipated and encloure mechanical strength.

  • Example Diagram for Distribution Box Use

  • Features

Copper free aluminum, plastic-sprayed surface.

Ex d type flameproof enclosure.

Degree of protection: IP66-IP67.

  • Application

  • Technical Data

Marking ATEX: II2 G Ex db IIB+H2 T6/T5 Gb

                         II2 D Ex tb IIIC T80ºC/95ºC Db IP66

Marking IECEx:Ex db ⅡB+H₂ T6/T5 Gb

                         Ex tb ⅢC T80℃/T95℃ Db IP66

Marking UL1203: Class I, Division 1, Groups C, D

                            Class I, Division 2, Groups C, D

                            Class II, Division 1, Groups E, F, G

                            Class II, Division 2, Groups F, G

                            Class III

Standards: EN 60079-0, EN 60079-1,EN 60079-31, IEC 60079-0, IEC 60079-1, IEC 60079-31

Rated Voltage :  Max.800V

Rated Current: Cable Cross Section(mm²) 2.5  4   6  10  16   35   70   240

                         Rated Current(A)                24  32 41 57  76  125 192  400

Ambient Temperature:-60℃ to + 60℃

Type of Flameproof Joint:Plane Joint 

  • Ordering Guide

  • Specification of Cable Entry
  A,B,C,D stands for the directiond of cable entries
Max.number of cable entry
Enclosure type A B C D E F G
Dimension A/B C/D A/B C/D A/B C/D A/B C/D A/B C/D A/B C/D A/B C/D
M20*1.5 5 8 5 10 5 12 16 20 22 30 24 40 45 65
M25*1.5 5 7 5 9 5 10 12 15 15 20 18 27 30 44
M32*1.5 2 3 2 4 2 6 9 12 12 16 14 21 25 36
M40*1.5 2 2 2 3 2 4 5 6 6 9 8 12 15 21
M50*1.5 1 2 1 3 1 3 4 5 5 7 5 9 12 12
M63*1.5 1 2 1 2 1 3 2 3 3 5 4 7 7 10
Note: 1. No cable entry for standard design. Cable entries shall be drilled by user. 2. No cable entry device.
  • IIIustration of EX-PD61 Distribution Equipment for Terminal Box Use
Cable Cross-sectional Area(mm)² Table for Max number of fitted terminal
Enclosure type number(Note: The enclosure type number is correspondent to the size. For example: A stands for the enclosure of 200x250)
A B C D E F G H
2.5(a) 20 28 36 72 100 140 270 270
4(b) 18 25 32 64 90 130 240 240
6(c) 15 21 28 56 80 100 210 210
10(d) 12 18 24 24 60 80 165 165
16(e) 9 15 20 20 25 70 135 135
35(f) - 5 5 10 15 24 64 64
70(g) - - - 5 10 18 25 25
120(h) - - - - 5 5 12 12
185(i) - - - - - 5 10 10
240(j) - _ - - - 5 5 5
300(k) - - - - - 5 5 5
Terminal Arrangement (Number of terminal rows) 1 1 1 2 2 2 2 2

  • Features

Copper free aluminum, stainless steel.

Plastic-sprayed surface.

Earth leakage protection device is optional.

Degree of protection: IP66-IP67.

  • Application

  • Technical Data

Marking ATEX: Ⅱ 2 G Ex d ⅡB T6 Gb

                         Ⅱ 2 D Ex tb ⅢC T80℃ Db IP66

Marking IECEx: Ex db ⅡB+H₂ T6 Gb

                          Ex tb ⅢC T80℃ Db IP66

Marking UL1203: Class I, Division 1, Groups C, D 

                             Class I, Division 2, Groups C, D

                             Class II, Division 1, Groups E, F, G

                             Class II, Division 2, Groups F, G

                             Class III

Standards : EN 60079-0, EN 60079-1,EN 60079-31, IEC 60079-0, IEC 60079-1, IEC 60079-31

Rated Voltage: Max.690V AC, 50/60Hz

Rated Current: Max.100A

Branch Current: 1A, 2A, 4A, 6A, 10A, 16A, 20A, 25A, 32A

Ambient Temperature: -60℃ to + 55℃

Degree of Protection: IP66, IP67

Cable Entry: Standard M□×1.5 Plug(See the Selection Table)

Entry Direction: Bottom(in and out)

Cable Entry Device:Optional

Type of Flameproof Joint: Cylindrical Joint, Threaded Joint, Plane Joint.

Installation Type: Wall mounting(standard); Bracket mounting(optional)

Built-in Components:

Main switch: miniature circuit breaker(MCB) or molded case circuit break(Noted: earth leakage protection on request)                   Branch switch: miniature circuit breaker(MCB) or molded case circuit breaker (MCCB) (Noted: earth  leakage protection on request)                                        

Terminal Indicator: Red, green, yellow

  • Ordering Guide

  • Electrical diagram

  • Selection table of EX-PD61-ZM illumination distribution boxes
Code Description Cable entries
Main switch Number of branch Branch switch Branch current Number of indicator
EX-PD61-ZM-/4□/K/□ MCB or MCCB Current Max.100A 4 MCB 1P/2P 1A 2A 4A 6A 10A 16A 20A 25A 32A On request 3 1*M32*1.5+4*M25*1.5
EX-PD61-ZM-/6□/K/□ 6 3 1*M40*1.5+6*M25*1.5
EX-PD61-ZM-/8□/K/□ 8 3 1*M40*1.5+8*M25*1.5
EX-PD61-ZM-/10□/K/□ 10 3 1*M40*1.5+10*M25*1.5
EX-PD61-ZM-/12□/K/□ 12 3 1*M40*1.5+12*M25*1.5
EX-PD61-ZM-4/□ _ 4 MCB 1P/2P 1A 2A 4A 6A 10A 16A 20A 25A 32A On request 3 1*M32*1.5+4*M25*1.5
EX-PD61-ZM-6/□ 6 3 1*M40*1.5+6*M25*1.5
EX-PD61-ZM-8/□ 8 3 1*M40*1.5+8*M25*1.5
EX-PD61-ZM-10/□ 10 3 1*M40*1.5+10*M25*1.5
EX-PD61-ZM-12/□ 12 3 1*M40*1.5+12*M25*1.5
  • Odering instruction:

1. Please specify the number and size of the cable inlets and the mounting surface of the housing.

2. The user provides the electrical diagram. If you need light controller, AC contactor or thermal relay control, please specify.

3. Please specify special requirements when ordering.

Dimensional drawings

EX-PD61-ZM-/4□/K/□

EX-PD61-ZM-/6□/K/□

EX-PD61-ZM-/8□/K/□

EX-PD61-ZM-/10□/K/□

EX-PD61-ZM-/12□/K/□

  • Features

Copper free aluminum, stainless steel.

Plastic-sprayed surface.

Earth leakage protection device is optional.

Degree of protection: IP66-IP67.

  • Application

  • Technical Data

Marking ATEX: II 2 G Ex db ⅡB + H₂ T6 Gb

                         II 2 D Ex tb ⅢC T80℃ Db IP66

Marking IECEx: Ex db Ⅱ B+H₂ T6 Gb

                          Ex tb ⅢC T80℃ Db IP66

Marking UL1203: Class I, Division 1, Groups C, D

                            Class I, Division 2, Groups C, D

                            Class II, Division 1, Groups E, F, G

                            Class II, Division 2, Groups F, G

                            Class III

Standards: EN60079-0, EN60079-1 , EN60079-31, IEC60079-0, IEC 60079-1, IEC 60079-31

Rated Voltage: Max.690V AC, 50/60Hz

Branch Current: : 1A, 2A, 4A, 6A, 10A, 16A, 20A, 25A, 32A, 40A, 50A, 63A, 80A, 100A, 125A, 160A, 200A, 250A, 320A, 400A

Ambient Temperature: -60℃ to + 55℃

Degree of Protection: IP66,IP67

Cable Entry: Standard M□× 1.5 Plug ( See the Selection Table )

Entry Direction: Bottom (in and out)

Cable Entry Device: Optional

Type of Flameproof Joint: Wall Mounting(Standard); Bracket Mounting(Optional)

Built-in Components: Main switch: miniature circuit breaker (MCB)or molded case circuit breaker(MCCB)

                                  (Noted:earth leakage protection on request)

                                  Branch switch: miniature circuit breaker (MCB)or molded case circuit breaker(MCCB)

                                   (Noted:earth leakage protection on request)

                                   Terminal

                                   Indicator: Red, green, yellow

  • Ordering Guide

  • Selection table of EX-PD61-ZM power distribution boxes
Code Description Cable entries
Main switch Number of branch Branch switch Branch current Number of indicator
EX-PD61-DL-/4□/K/□ MCB or MCCB Current Max.100A 4 MCB or MCCB 3P 1A 2A 4A 6A 10A 16A 20A 25A 32A 40A 50A 63A 80A 100A 125A 160A 200A 250A 320A 400A On request 3 1*M50(M63,M75,M90)*1.5 4*M25(M32,M40,M50,M63)*1.5
EX-PD61-DL-/6□/K/□ 6 3 1*M50(M63,M75,M90)*1.5 6*M25(M32,M40,M50,M63)*1.5
EX-PD61-DL-/8□/K/□ 8 3 1*M50(M63,M75,M90)*1.5 8*M25(M32,M40,M50,M63)*1.5
EX-PD61-DL-/10□/K/□ 10 3 1*M50(M63,M75,M90)*1.5 10*M25(M32,M40,M50,M63)*1.5
EX-PD61-DL-/12□/K/□ 12 3 1*M50(M63,M75,M90)*1.5 12*M25(M32,M40,M50,M63)*1.5
EX-PD61-DL-4/□ _ 4 MCB or MCCB 3P 1A 2A 4A 6A 10A 16A 20A 25A 32A 40A 50A 63A 80A 100A 125A 160A 200A 250A 320A 400A On request 3 1*M40*1.5+4*M25*1.5
EX-PD61-DL-6/□ 6 3 1*M40*1.5+6*M25*1.5
EX-PD61-DL-8/□ 8 3 1*M40*1.5+8*M25*1.5
EX-PD61-DL-10/□ 10 3 1*M40*1.5+10*M25*1.5
EX-PD61-DL-12/□ 12 3 1*M40*1.5+12*M25*1.5

Odering instruction: 1. Please specify the number and size of the cable inlets and the mounting surface of the housing.

                                 2. The user provides the electrical diagram. If you need light controller, AC contactor or thermal relaycontrol,  please specify.

                                 3. Please specify special requirements when ordering

  • Features

Copper free aluminum, stainless steel.

Plastic-sprayed surface.

Earth leakage protection device is optional.

Degree of protection: IP66-IP67.

  • Application

  • Technical Data

Marking ATEX: II 2 G Ex db ⅡB + H₂ T6 Gb

II 2 D Ex tb ⅢC T80℃ Db IP66

Marking IECEx: Ex db Ⅱ B+H₂ T6 Gb

Ex tb ⅢC T80℃ Db IP66

Marking UL1203: Class I, Division 1, Groups C, D

Class I, Division 2, Groups C, D

Class II, Division 1, Groups E, F, G

Class II, Division 2, Groups F, G

Class III

Standards: EN60079-0, EN60079-1 , EN60079-31, IEC60079-0, IEC 60079-1, IEC 60079-31

Rated Voltage: Max.415V AC

Rated Current: 10A

Ambient Temperature: -60℃ to + 60℃

Degree of Protection: IP66,IP67

Cable Entry: Standard M□× 1.5 Plug ( See the Selection Table )

Entry Direction: Bottom 

Cable Entry Device: Standard M□× 1.5 Plug ( See the Selection Table )

Type of Flameproof Joint: Cylindrical Joint,Threaded Joint,Plane Joint.

Built-in Components: EX-A Pushbutton, EX-D Indicator,EX-K Control Switch, Explosion-proof Ammeter/Voltmeter

Installation Type: Wall Mounting

Indicator: Red, green, yellow

  • Ordering Guide

  • Selection table of control stations EX-PD61-ZC

  • Features

Copper free aluminum, stainless steel.

Plastic-sprayed surface.

Earth leakage protection device is optional.

Degree of protection: IP66-IP67.

  • Application

  • Technical Data

Marking ATEX: II 2 G Ex db ⅡB + H₂ T6 Gb

                         II 2 D Ex tb ⅢC T80℃ Db IP66

Marking IECEx: Ex db Ⅱ B+H₂ T6 Gb

                          Ex tb ⅢC T80℃ Db IP66

Marking UL1203: Class I, Division 1, Groups C, D

                             Class I, Division 2, Groups C, D

                             Class II, Division 1, Groups E, F, G

                             Class II, Division 2, Groups F, G

                             Class III

Standards: EN60079-0, EN60079-1 , EN60079-31, IEC60079-0, IEC 60079-1, IEC 60079-31

Type of Flameproof Joint: Cylindrical Joint,Plane Joint.

  • Ordering Guide

  • Dimensional Drawing

EX-PD61-LK-63/□/□/□

EX-PD61-LK-160/□/□/□

EX-PD61-LK-250/□/□/□

  • Features

Copper free aluminum, stainless steel.

Plastic-sprayed surface.

Earth leakage protection device is optional.

Degree of protection: IP66-IP67.

  • Application

  • Technical Data

Marking ATEX: II 2 G Ex db ⅡB + H₂ T6 Gb

                         II 2 D Ex tb ⅢC T80℃ Db IP66

Marking IECEx: Ex db Ⅱ B+H₂ T6 Gb

                          Ex tb ⅢC T80℃ Db IP66

Marking UL1203: Class I, Division 1, Groups C, D

                             Class I, Division 2, Groups C, D

                             Class II, Division 1, Groups E, F, G

                             Class II, Division 2, Groups F, G

                             Class III

Standards: EN60079-0, EN60079-1 , EN60079-31, IEC60079-0, IEC 60079-1, IEC 60079-31

Rated Voltage: 380/400V AC, 50/60Hz

Rated Current: 10A

Ambient Temperature: T6/T80 ℃ for Tamb: -60℃ to +50℃;

                                    T5/T95 ℃ for Tamb: -60℃ to +60℃

Cable Entry: Standard M□× 1.5 Plug ( See the Selection Table )

Entry Direction: Bottom(in and out)

Cable Entry Device: Optional

Type of Flameproof Joint: Cylindrical Joint,Threaded Joint,Plane Joint.

Built-in Components: Miniature circuit breaker(MCB) or moulded case circuit breaker( MCCB)

                                  AC contactor, thermal overload relay, indicator, button

  • Ordering Guide

  • Selection table
Direct Start
Model Control motor power(kw) Rated current of circuit breaker(A) Adjustable range of setting current of thermalr elay(A) Rated current of contactor(A) Cable entry size
EX-PD61 QD-4/16/7~10 4 16 7~10,le=8.5 9 2*M25*1.5
EX-PD61 QD-5.5/20/9~13 5.5 20 9~13,le=11 12 2*M25*1.5
EX-PD61 DQ-7.5/25/12~18 7.5 25 12~18,le=16 18 2*M32*1.5
EX-PD61 QD-11/32/16~24 11 32 16~24,le=23 25 2*M32*1.5
EX-PD61 QD-15/40/23~32 15 40 23~32,le=30 32 2*M32*1.5
EX-PD61 QD-18.5/50/30~38 18.5 50 30~38,le=36 40 2*M40*1.5
EX-PD61 QD-22/63/37~50 22 63 37~50,le=46 50 2*M40*1.5

 

Forward and Reverse Start
Model Control motor power(kw) Rated current of circuit breaker(A) Adjustable range of setting current of thermalr elay(A) Rated current of contactor(A) Cable entry size
EX-PD61 QD-4/16/7~10 N 4 16 7~10,le=8.5 9 2*M25*1.5
EX-PD61 QD-5.5/20/9~13 N 5.5 20 9~13,le=11 12 2*M25*1.5
EX-PD61 DQ-7.5/25/12~18 N 7.5 25 12~18,le=16 18 2*M32*1.5
EX-PD61 QD-11/32/16~24 N 11 32 16~24,le=23 25 2*M32*1.5
EX-PD61 QD-15/40/23~32 N 15 40 23~32,le=30 32 2*M32*1.5
EX-PD61 QD-18.5/50/30~38 N 18.5 50 30~38,le=36 40 2*M40*1.5
EX-PD61 QD-22/63/37~50 N 22 63 37~50,le=46 50 2*M40*1.5

 

  • QA:

Q1. How do you ship the goods and how long does it take to arrive?

A: Ship by DHL, UPS, FedEx or TNT. It takes 3-5 days to arrive. Airline and sea shipping also optional.

Q2. Can I have a sample order for led light?

A: Yes, we welcome sample order to test and check quality. Mixed samples are acceptable

Hot Products

Zone 1 Zone 2 Atex Hazardous Area Explosion-proof Light Explos Proof Led Light Explosion Proof Lamp ...
Explosion PD61 Series Features: Copper free aluminum, plastic-sprayed surface. Ex d type flameproof ...
Explosion-proof Waterproof Price Electric Junction Box HD51 Series-UL Certified FEATURES The EX-HD51...
Customized Junction Box Special Junction Box Explosion Proof EJB Series Junction Box-19 Key Features ...
Factory Price Atex/IECEX Alloy Explosion Proof enclosures Explosion Bushings-HC Series-35 Features: ...
Factory supply fire-retardant power waterproof junction box explosion proof junction box HC Features...