Home Companies Guangdong Bell Experiment Equipment Co., Ltd

Non Linear -70 To 150C Humidity And Temperature Controlled Chamber No Load

Guangdong Bell Experiment Equipment Co., Ltd
Active Member

Contact Us

[China] country

Address: No.11 Wusong 1st Street, Dongcheng District, Dongguan 523117, Guangdong, China

Contact name:Choi

Inquir Now

Guangdong Bell Experiment Equipment Co., Ltd

Non Linear -70 To 150C Humidity And Temperature Controlled Chamber No Load

Country/Region china
City & Province dongguan guangdong
InquireNow

Product Details

Temperature Humidity Test Chamber Approx 1℃/ mins, Average Non-linear, No Load

 

Advantage

This equipment is widely applied to electronic and electric products, components and materials by constant high low temperature, temperature change, cycling, damp heat, etc environment simulation reliability test.

 

Features

With high precision perfect external design, external with double sides cold rolled plate electrostatic powder coated material, internal with SUS#304 high temperature resistant stainless steel. Insulation material adopts fire resistant high strength PU polyurethane foaming thermal insulating material. More than 20% energy saving is achieved & thanks to the introduction of Japan & German advanced refrigerator control technology. Control systems and control circuit components are introduced with the famous brand.

 

Standard Compliance

  • IEC68-2-1 (GB2423.1-2008) Environmental testing - Part 2: Test methods - Tests A: Cold

  • IEC68-2-2 (GB2423.2-2008) Environmental testing for electric and electronic products Test methods - Tests B: Dry Heat

  • IEC68-2-3 (GB2423.3-2006) Environmental testing for electric and electronic products - Part 2: Testing method test Cab: Damp heat Steady state

  • IEC68-2-30 (GB2423.4-2008) Environmental testing for electric and electronic products - Part 2: Test method - Test Db: Damp heat,cyclic ( 12h+12h cycle)

  • IEC68-2-14 (GB2423.22-2008) Environmental testing for electric and electronic products-Part 2:Test methods-Test N:Change of temperature

  • MIL-STD-810D (GJB150.3A-2009) High temperature test

  • MIL-STD-810D (GJB150.4A-2009) Low temperature test

  • MIL-STD-810D (GJB150.9A-2009) Damp heat test

 

Performance parameters

Model

BTH-80

BTH-150

BTH-225

BTH-408

BTH-800

BTH-1000

Space

W x H x D (mm)

500x600x500

500x600x500

500x750x600

600x850x800

1000x1000x800

1000x1000x1000

External Dimension

W x H x D (mm)

650x1650x1270

700x1700x1370

700x1750x1420

650x1650x1270

1200x1900x1620

1200x1900x1820

Cooling Method

Air-cooling

Air-cooling

Air-cooling

Air-cooling

Air-cooling

Air-cooling

Temperature Range

A:-0~150℃ B:-20~150℃ C:-40~150℃ D:-70~150℃

Humidity Range

20%RH-98%RH (details see temperature humidity control diagram).

Temperature Fluctuation

± 0.5℃

Humidity Fluctuation

± 2%RH

Temperature Deviation

≤ 2.0℃

Humidity Deviation

A)> 75%RH: ≤+2,-3% RH,B)<75% RH: ≤±5% RH.

Temperature Uniformity

≤± 2.0℃

Humidity Uniformity

+2,-3%RH

Heating Rate

Approx 3℃ / mins,average non-linear, no load

Cooling Rate

Approx 1℃ / mins,average non-linear, no load

Temperature Overshoot

≤± 2℃

Internal Material

1.2mm thick SUS#304 high & low temperature resistance stainless steel.

External Material

Adopt flame retardant high strength PU Polyurethane foam insulation material.

Control Method

Touch screen programmable PLC, with USB interface, with RJ485 interface can be connected to computer controlling, special network control software, convenient remote monitoring, data acquisition.

Compressor

Tecumseh (France)-fully air-cooled double-fall cooling compressor. Or Bock (Germany) semi-enclosed air-cooled refrigeration.

Safety Protection

Explosion-proof pressure relief device, explosion-proof chain, mobile phone alarm device, networking, smoke exhaust device, fire extinguishing device, etc.

 

 

Hot Products

Temperature Humidity Test Chamber Approx 3℃/mins, Average Non-linear, No Load Advantage This ...
ISO 9001:2015 Temperature Humidity Test Chamber Approx 1℃/ mins Advantage This equipment is widely ...
Temperature Humidity Test Chamber Approx 1℃/ mins, Average Non-linear, No Load Advantage This ...
China Temperature Humidity Test Chamber Approx 1℃/ mins, Average Non-linear, No Load Advantage This ...
DGBELL Temperature Humidity Test Chamber Approx 1℃/ mins, Average Non-linear, No Load Standard ...
DGBELL Temperature Humidity Test Chamber Approx 1℃/ mins, Average Non-linear Advantage This ...