Home Companies Shanghai Korain Biotech Co., Ltd

Mouse ELISA Test Kit E1260Mo 2 Hours Assay Time With Strong Sensitivity

Shanghai Korain Biotech Co., Ltd
Active Member

Contact Us

[China] country

Address: #1008.Junjiang Internatioanl Bldg. 228 Ningguo Rd. Yangpu Dist. Shanghai. 200090. China

Contact name:

Inquir Now

Shanghai Korain Biotech Co., Ltd

Mouse ELISA Test Kit E1260Mo 2 Hours Assay Time With Strong Sensitivity

Country/Region china
City & Province shanghai shanghai
Categories Dyestuff Intermediates
InquireNow

Product Details

Mouse ELISA Test Kit Pulmonary Surfatcant-associated Protein C ELISA Kit With Strong Sensitivity

 

Reagent Preparation

All reagents should be brought to room temperature before use.

Standard Reconstitute the 120μl of the standard (320ng/ml) with 120μl of standard diluent to generate a 160ng/ml standard stock solution. Allow the standard to sit for 15 mins with gentle agitation prior to making dilutions. Prepare duplicate standard points by serially diluting the standard stock solution (160ng/ml) 1:2 with standard diluent to produce 80ng/ml, 40ng/ml, 20ng/ml and 10ng/ml solutions. Standard diluent serves as the zero standard(0 ng/ml). Any remaining solution should be frozen at -20°C and used within one month. Dilution of standard solutions suggested are as follows:

 

160ng/mlStandard No.5120μl Original Standard + 120μl Standard Diluent
80ng/mlStandard No.4120μl Standard No.5 + 120μl Standard Diluent
40ng/mlStandard No.3120μl Standard No.4 + 120μl Standard Diluent
20ng/mlStandard No.2120μl Standard No.3 + 120μl Standard Diluent
10ng/mlStandard No.1120μl Standard No.2 + 120μl Standard Diluent

 

Standard ConcentrationStandard No.5Standard No.4Standard No.3Standard No.2Standard No.1
320ng/ml160ng/ml80ng/ml40ng/ml20ng/ml10ng/ml

 

Wash Buffer Dilute 20ml of Wash Buffer Concentrate 25x into deionized or distilled water to yield 500 ml of 1x Wash Buffer. If crystals have formed in the concentrate, mix gently until the crystals have completely dissolved.

 

Cat.No E1260Mo

Standard Curve Range: 0.5ng/ml - 300ng/ml

Sensitivity: 0.26ng/ml

Size: 96 wells

Storage: Store the reagents at 2-8°C. For over 6-month storage refer to the expiration date keep it at -20°C. Avoid repeated thaw cycles. If individual reagents are opened it is recommended that the kit be used within 1 month.

*This product is for research use only, not for use in diagnosis procedures. It’s highly recommend to read this instruction entirely before use.

 

Intended Use

This sandwich kit is for the accurate quantitative detection of Mouse Pulmonary Surfatcant-associated Protein C (also known as SP-C) in serum, plasma, cell culture supernates, cell lysates, tissue homogenates.

 

Precision

Intra-Assay Precision (Precision within an assay) Three samples of known concentration were tested on one plate to assess intra-assay precision.

Inter-Assay Precision (Precision between assays) Three samples of known concentration were tested in separate assays to assess inter-assay precision.

CV(%) = SD/mean x 100

Intra-Assay: CV<8%

Inter-Assay: CV<10%

 

Precautions

  • Prior to use, the elisa kit and sample should be warmed naturally to room temperature 30 minutes.
  • This instruction must be strictly followed in the experiment.
  • Once the desired number of strips has been removed, immediately reseal the bag to protect the remain from deterioration. Cover all reagents when not in use.
  • Make sure pipetting order and rate of addition from well-to-well when pipetting reagents.
  • Pipette tips and plate sealer in hand should be clean and disposable to avoid cross-contamination.
  • Avoid using the reagents from different batches together.
  • Substrate solution B is sensitive to light, don’t expose substrate solution B to light for a long time.
  • Stop solution contains acid. Please wear eye, hand and skin protection when using this material. Avoid contact of skin or mucous membranes with kit reagent.
  • The elisa kit should not be used beyond the expiration date.

Reagent Provided

ComponentsQuantity
Standard Solution (320ng/ml)0.5ml x1
Pre-coated ELISA Plate12 * 8 well strips x1
Standard Diluent3ml x1
Streptavidin-HRP6ml x1
Stop Solution6ml x1
Substrate Solution A6ml x1
Substrate Solution B6ml x1
Wash Buffer Concentrate (25x)20ml x1
Biotinylated Mouse SP-C Antibody1ml x1
User Instruction1
Plate Sealer2 pics
Zipper bag1 pic

 

Summary

1. Prepare all reagents, samples and standards.

2. Add sample and ELISA reagent into each well. Incubate for 1 hour at 37°C.

3. Wash the plate 5 times.

4. Add substrate solution A and B. Incubate for 10 minutes at 37°C.

5. Add stop solution and color develops.

6. Read the OD value within 10 minutes.

 

Calculation of Result

Construct a standard curve by plotting the average OD for each standard on the vertical (Y) axis against the concentration on the horizontal (X) axis and draw a best fit curve through the points on the graph. These calculations can be best performed with computer-based curve-fitting software and the best fit line can be determined by regression analysis.

Hot Products

Highly Sensitive Human Pyruvate Kinase Muscle ELISA Kit M2-PK ELISA Assay Kit With Oem Service Cat...
Sandwich Type Human Soluble Fibrin Monomer Complex ELISA Test Kit With High Sensitivity Summary 1. ...
96 Wells Human Sandwich ELISA Kit High Specificity SFMC ELISA Assay Kit 2 Hours Assay Length Cat.No ...
Sandwich Type Human Soluble Fibrin Monomer Complex ELISA Test Kit With High Sensitivity Cat.No ...
Mouse ELISA Test Kit Pulmonary Surfatcant-associated Protein C ELISA Kit With Strong Sensitivity ...
96 Well Plate Mouse High Specificity SP-C Sandwich ELISA Kit For Accurate Quantitative Detection Cat...