Home Companies Shanghai Korain Biotech Co., Ltd

0.028ng/ml Sensitivity Cys C Human ELISA Kit CE / ISO / MSDS Standard

Shanghai Korain Biotech Co., Ltd
Active Member

Contact Us

[China] country

Address: #1008.Junjiang Internatioanl Bldg. 228 Ningguo Rd. Yangpu Dist. Shanghai. 200090. China

Contact name:

Inquir Now

Shanghai Korain Biotech Co., Ltd

0.028ng/ml Sensitivity Cys C Human ELISA Kit CE / ISO / MSDS Standard

Country/Region china
City & Province shanghai shanghai
Categories Dyestuff Intermediates
InquireNow

Product Details

96 wells Customized Human Cystatin C ELISA Kit

 

Cat.No E1104Hu

Storage: Store the reagents at 2-8°C. For over 6-month storage refer to the expiration date keep it at -20°C. Avoid repeated thaw cycles. If individual reagents are opened it is recommended that the kit be used within 1 month.

* This product is for research use only, not for use in diagnosis procedures. It’s highly recommend to read this instruction entirely before use.

 

Assay Principle

This kit is an Enzyme-Linked Immunosorbent Assay (ELISA). The plate has been pre-coated with Human Cys-C antibody. Cys-C present in the sample is added and binds to antibodies coated on the wells. And then biotinylated Human Cys-C Antibody is added and binds to Cys-C in the sample. Then Streptavidin-HRP is added and binds to the Biotinylated Cys-C antibody. After incubation unbound Streptavidin-HRP is washed away during a washing step. Substrate solution is then added and color develops in proportion to the amount of Human Cys-C. The reaction is terminated by addition of acidic stop solution and absorbance is measured at 450 nm.

 

Reagent Provided

ComponentsQuantity
Standard Solution (24ng/ml)0.5ml x1
Pre-coated ELISA Plate12 * 8 well strips x1
Standard Diluent3ml x1
Streptavidin-HRP6ml x1
Stop Solution6ml x1
Substrate Solution A6ml x1
Substrate Solution B6ml x1
Wash Buffer Concentrate (30x)20ml x1
Biotinylated Human Cys-C Antibody1ml x1
User Instruction1
Plate Sealer2 pics
Zipper bag1 pic

 

Reagent Preparation

All reagents should be brought to room temperature before use.

Standard Reconstitute the 120μl of the standard (24ng/ml) with 120μl of standard diluent to generate a 12ng/ml standard stock solution. Allow the standard to sit for 15 mins with gentle agitation prior to making dilutions. Prepare duplicate standard points by serially diluting the standard stock solution (12ng/ml) 1:2 with standard diluent to produce 6ng/ml, 3ng/ml, 1.5ng/ml and 0.75ng/ml solutions. Standard diluent serves as the zero standard(0 ng/ml). Any remaining solution should be frozen at -20°C and used within one month. Dilution of standard solutions suggested are as follows:

 

12ng/mlStandard No.5120μl Original Standard + 120μl Standard Diluent
6ng/mlStandard No.4120μl Standard No.5 + 120μl Standard Diluent
3ng/mlStandard No.3120μl Standard No.4 + 120μl Standard Diluent
1.5ng/mlStandard No.2120μl Standard No.3 + 120μl Standard Diluent
0.75ng/mlStandard No.1120μl Standard No.2 + 120μl Standard Diluent

 

Standard ConcentrationStandard No.5Standard No.4Standard No.3Standard No.2Standard No.1
24ng/ml12ng/ml6ng/ml3ng/ml1.5ng/ml0.75ng/ml

 

Wash Buffer Dilute 20ml of Wash Buffer Concentrate 30x into deionized or distilled water to yield 500 ml of 1x Wash Buffer. If crystals have formed in the concentrate, mix gently until the crystals have completely dissolved.

 

Calculation of Result

Construct a standard curve by plotting the average OD for each standard on the vertical (Y) axis against the concentration on the horizontal (X) axis and draw a best fit curve through the points on the graph. These calculations can be best performed with computer-based curve-fitting software and the best fit line can be determined by regression analysis.

 

Standard Curve Range: 0.05ng/ml - 20ng/ml

Sensitivity: 0.028ng/ml

Size: 96 wells

 

References

Crawford F.C., Freeman M.J., Schinka J.A., Abdullah L.I., Gold M., Hartman R., Krivian K., Morris M.D., Richards D., Duara R., Anand R., Mullan M.J.
Neurology 55:763-768(2000)

 
 

Hot Products

96 wells Human specificity and precision Insulin INS ELISA Kit Reagent Provided Components Quantity ...
Human specificity and precision Insulin ELISA Kit 96 wells Cat.No E0010Hu Standard Curve Range: 0...
96 wells Human specificity and precision INS ELISA Kit Cat.No E0010Hu Standard Curve Range: 0.2mIU/L ...
96 wells Human Cystatin C CysC ELISA Kit Customized Cat.No E1104Hu Standard Curve Range: 0.05ng/ml - ...
96 wells Customized Human Cystatin C ELISA Kit Cat.No E1104Hu Storage: Store the reagents at 2-8°C. ...