Home Companies Shanghai Korain Biotech Co., Ltd

Sandwich Immunosorbent Human ELISA Kit ASB2 96 Well Plate 3.04ng/L Sensitivity

Shanghai Korain Biotech Co., Ltd
Active Member

Contact Us

[China] country

Address: #1008.Junjiang Internatioanl Bldg. 228 Ningguo Rd. Yangpu Dist. Shanghai. 200090. China

Contact name:

Inquir Now

Shanghai Korain Biotech Co., Ltd

Sandwich Immunosorbent Human ELISA Kit ASB2 96 Well Plate 3.04ng/L Sensitivity

Country/Region china
City & Province shanghai shanghai
Categories Dyestuff Intermediates
InquireNow

Product Details

Sandwich Immunosorbent Assay Kit Human ASB2 Sandwich Immunosorbent Assay Kit 96 Well Plate
 
Cat.No E4952Hu
 
*This product is for research use only, not for use in diagnosis procedures. It’s highly recommend to read this instruction entirely before use.
 
Assay Procedure
1. Prepare all reagents, standard solutions and samples as instructed. Bring all reagents to room temperature before use. The assay is performed at room temperature.
2. Determine the number of strips required for the assay. Insert the strips in the frames for use. The unused strips should be stored at 2-8°C.
3. Add 50μl standard to standard well. Note: Don’t add antibody to standard well because the standard solution contains biotinylated antibody.
4. Add 40μl sample to sample wells and then add 10μl anti-ASB2 antibody to sample wells, then add 50μl streptavidin-HRP to sample wells and standard wells ( Not blank control well ). Mix well. Cover the plate with a sealer. Incubate 60 minutes at 37°C.
5. Remove the sealer and wash the plate 5 times with wash buffer. Soak wells with at least 0.35 ml wash buffer for 30 seconds to 1 minute for each wash. For automated washing, aspirate all wells and wash 5 times with wash buffer, overfilling wells with wash buffer. Blot the plate onto paper towels or other absorbent material.
6. Add 50μl substrate solution A to each well and then add 50μl substrate solution B to each well. Incubate plate covered with a new sealer for 10 minutes at 37°C in the dark.
7. Add 50μl Stop Solution to each well, the blue color will change into yellow immediately.
8. Determine the optical density (OD value) of each well immediately using a microplate reader set to 450 nm within 10 minuets after adding the stop solution.
 
Precision
Intra-Assay Precision (Precision within an assay) Three samples of known concentration were tested on one plate to assess intra-assay precision.
Inter-Assay Precision (Precision between assays) Three samples of known concentration were tested in separate assays to assess inter-assay precision.
CV(%) = SD/mean x 100
Intra-Assay: CV<8%
Inter-Assay: CV<10%
 
Intended Use
This sandwich kit is for the accurate quantitative detection of human Ankyrin Repeat and SOCS Box Protein 2 (also known as ASB2) in serum, plasma, cell culture supernates, cell lysates, tissue homogenates.
 
Assay Principle
This elisa test kit is an Enzyme-Linked Immunosorbent Assay (ELISA). The plate has been pre-coated with human ASB2 antibody. ASB2 present in the sample is added and binds to antibodies coated on the wells. And then biotinylated human ASB2 Antibody is added and binds to ASB2 in the sample. Then Streptavidin-HRP is added and binds to the Biotinylated ASB2 antibody. After incubation unbound Streptavidin-HRP is washed away during a washing step. Substrate solution is then added and color develops in proportion to the amount of human ASB2. The reaction is terminated by addition of acidic stop solution and absorbance is measured at 450 nm.
 
Standard Curve Range: 5ng/L - 1000ng/L
Sensitivity: 3.04ng/L
Size: 96 wells
 
Reagent Provided

ComponentsQuantity
Standard Solution (1280ng/L)0.5ml x1
Pre-coated ELISA Plate12 * 8 well strips x1
Standard Diluent3ml x1
Streptavidin-HRP6ml x1
Stop Solution6ml x1
Substrate Solution A6ml x1
Substrate Solution B6ml x1
Wash Buffer Concentrate (25x)20ml x1
Biotinylated human ASB2 Antibody1ml x1
User Instruction1
Plate Sealer2 pics
Zipper bag1 pic

 
Specimen Collection
Serum Allow serum to clot for 10-20 minutes at room temperature. Centrifuge at 2000-3000 RPM for 20 minutes.
 
Plasma Collect plasma using EDTA or heparin as an anticoagulant. Centrifuge samples for 15 minutes at 2000-3000 RPM at 2 - 8°C within 30 minutes of collection.
 
Urine Collect by sterile tube. Centrifuge at 2000-3000 RPM for approximately 20 minutes. When collecting pleuroperitoneal fluid and cerebrospinal fluid, please follow the procedures above-mentioned.
 
Cell Culture Supernatant Collect by sterile tubes when examining secrete components. Centrifuge at 2000-3000 RPM for approximately 20 minutes. Collect the supernatants carefully. When examining the components within the cell, use PBS (pH 7.2-7.4) to dilute cell suspension to the cell concentration of approximately 1 million/ml. Damage cells through repeated freeze-thaw cycles to let out the inside components. Centrifuge at 2000-3000 RPM for approximately 20 minutes.
 
Tissue and other body fluids Rinse tissues in PBS (pH 7.4) to remove excess blood thoroughly and weigh before homogenization. Mince tissues and homogenize them in PBS (pH7.4) with a glass homogenizer on ice. Thaw at 2-8°C or freeze at -20°C. Centrifuge at 2000-3000 RPM for approximately 20 minutes.
 
Note

  • Sample concentrations should be predicted before being used in the assay. If the sample concentration is not within the range of the standard curve, users must contact us to determine the optimal sample for their particular experiments.
  • Samples to be used within 5 days should be stored at 2-8°C. Samples should be aliquoted or must be stored at -20°C within 1 month or -80°C within 6 months. Avoid repeated freeze thaw cycles.
  • Samples should be brought to room temperature before starting the assay.
  • Centrifuge to collect sample before use.
  • Samples containing NaN3 can’t be tested as it inhibits the activity of Horse Radish Peroxidase (HRP).
  • Collect the supernatants carefully. When sediments occurred during storage, centrifugation should be performed again.
  • Hemolysis can greatly impact the validity of test results. Take care to minimize hemolysis.

*Sample can't be diluted with this kit. Owing to the the material we use to prepare the kit, the sample matrix interference may falsely depress the specificity and accuracy of the assay.
 

Hot Products

Customized Human A Disintegrin and Metalloproteinase with Thrombospondin Motifs 19 ELISA Assay Kit ...
Human High Sensitive ADAMTS19 ELISA Kit A Disintegrin and Metalloproteinase with Thrombospondin ...
Strong Sensitivity ASB2 ELISA Test Kit Human Ankyrin Repeat and SOCS Box Protein 2 ELISA Kit For ...
Human High Sensitive Ankyrin Repeat and SOCS Box Protein 2 Sandwich ELISA Kit 2 Hours Assay Length ...
Sandwich Immunosorbent Assay Kit Human ASB2 Sandwich Immunosorbent Assay Kit 96 Well Plate Cat.No ...
Customized Human Cytosolic Carboxypetidase 3 ELISA Assay Kit For Accurate Quantitative Detection Cat...