Home Companies Shanghai Korain Biotech Co., Ltd

96 Well Plate Bovine ELISA Kits TLR4 With Oem Service For Research

Shanghai Korain Biotech Co., Ltd
Active Member

Contact Us

[China] country

Address: #1008.Junjiang Internatioanl Bldg. 228 Ningguo Rd. Yangpu Dist. Shanghai. 200090. China

Contact name:

Inquir Now

Shanghai Korain Biotech Co., Ltd

96 Well Plate Bovine ELISA Kits TLR4 With Oem Service For Research

Country/Region china
City & Province shanghai shanghai
Categories Dyestuff Intermediates
InquireNow

Product Details

96 Well Plate Bovine High Specificity and Sensitivity TLR4 ELISA Assay Kit With Oem Service
 

Cat.No E0242Bo

Size: 96 wells

Storage: Store the reagents at 2-8°C. For over 6-month storage refer to the expiration date keep it at -20°C. Avoid repeated thaw cycles. If individual reagents are opened it is recommended that the kit be used within 1 month.

*This product is for research use only, not for use in diagnosis procedures. It’s highly recommend to read this instruction entirely before use.

 

Precision

Intra-Assay Precision (Precision within an assay) Three samples of known concentration were tested on one plate to assess intra-assay precision.

Inter-Assay Precision (Precision between assays) Three samples of known concentration were tested in separate assays to assess inter-assay precision.

CV(%) = SD/mean x 100

Intra-Assay: CV<8%

Inter-Assay: CV<10%

 

Intended Use

This sandwich kit is for the accurate quantitative detection of Bovine Toll-like Receptor 4 (also known as TLR4) in serum, plasma, cell culture supernates, cell lysates, tissue homogenates.

 

Precautions

  • Prior to use, the kit and sample should be warmed naturally to room temperature 30 minutes.
  • This instruction must be strictly followed in the experiment.
  • Once the desired number of strips has been removed, immediately reseal the bag to protect the remain from deterioration. Cover all reagents when not in use.
  • Make sure pipetting order and rate of addition from well-to-well when pipetting reagents.
  • Pipette tips and plate sealer in hand should be clean and disposable to avoid cross-contamination.
  • Avoid using the reagents from different batches together.
  • Substrate solution B is sensitive to light, don’t expose substrate solution B to light for a long time.
  • Stop solution contains acid. Please wear eye, hand and skin protection when using this material. Avoid contact of skin or mucous membranes with kit reagent.
  • The ELISA Assay Kit should not be used beyond the expiration date.

 

Reagent Preparation

All reagents should be brought to room temperature before use.

Standard Reconstitute the 120μl of the standard (24ng/ml) with 120μl of standard diluent to generate a 12ng/ml standard stock solution. Allow the standard to sit for 15 mins with gentle agitation prior to making dilutions. Prepare duplicate standard points by serially diluting the standard stock solution (12ng/ml) 1:2 with standard diluent to produce 6ng/ml, 3ng/ml, 1.5ng/ml and 0.75ng/ml solutions. Standard diluent serves as the zero standard(0 ng/ml). Any remaining solution should be frozen at -20°C and used within one month. Dilution of standard solutions suggested are as follows:

 

12ng/mlStandard No.5120μl Original Standard + 120μl Standard Diluent
6ng/mlStandard No.4120μl Standard No.5 + 120μl Standard Diluent
3ng/mlStandard No.3120μl Standard No.4 + 120μl Standard Diluent
1.5ng/mlStandard No.2120μl Standard No.3 + 120μl Standard Diluent
0.75ng/mlStandard No.1120μl Standard No.2 + 120μl Standard Diluent

 

Standard ConcentrationStandard No.5Standard No.4Standard No.3Standard No.2Standard No.1
24ng/ml12ng/ml6ng/ml3ng/ml1.5ng/ml0.75ng/ml

 

Wash Buffer Dilute 20ml of Wash Buffer Concentrate 30x into deionized or distilled water to yield 600 ml of 1x Wash Buffer. If crystals have formed in the concentrate, mix gently until the crystals have completely dissolved.

 

Assay Procedure

1. Prepare all reagents, standard solutions and samples as instructed. Bring all reagents to room temperature before use. The assay is performed at room temperature.

2. Determine the number of strips required for the assay. Insert the strips in the frames for use. The unused strips should be stored at 2-8°C.

3. Add 50μl standard to standard well. Note: Don’t add antibody to standard well because the standard solution contains biotinylated antibody.

4. Add 40μl sample to sample wells and then add 10μl anti-TLR4 antibody to sample wells, then add 50μl streptavidin-HRP to sample wells and standard wells ( Not blank control well ). Mix well. Cover the plate with a sealer. Incubate 60 minutes at 37°C.

5. Remove the sealer and wash the plate 5 times with wash buffer. Soak wells with at least 0.35 ml wash buffer for 30 seconds to 1 minute for each wash. For automated washing, aspirate all wells and wash 5 times with wash buffer, overfilling wells with wash buffer. Blot the plate onto paper towels or other absorbent material.

6. Add 50μl substrate solution A to each well and then add 50μl substrate solution B to each well. Incubate plate covered with a new sealer for 10 minutes at 37°C in the dark.

7. Add 50μl Stop Solution to each well, the blue color will change into yellow immediately.

8. Determine the optical density (OD value) of each well immediately using a microplate reader set to 450 nm within 10 minuets after adding the stop solution.

 

Referances

"Bovine Toll-like receptor 4 (TLR4)."
Guionaud C.T., Dubey C., Jungi T.W.
Submitted (NOV-2001)

Hot Products

High Specificity Bovine Sandwich ELISA Kit High Sensitive Tri-iodothyronine ELISA Test Kit Cat.No ...
Bovine Strong Sensitivity and Precision T3 Immunoassay Test Kit 2 Hours Assay Length Cat.No E0215Bo ...
Bovine T3 Sandwich ELISA Kit Customized Tri-iodothyronine Immunoassay Test Kit 96 Wells Plate Cat.No ...
Laboratory Research Bovine Toll-like Receptor 4 ELISA Assay Kit With High Sensitivity and Specificit...
96 Well Plate Bovine High Specificity and Sensitivity TLR4 ELISA Assay Kit With Oem Service Cat.No ...
High Precision Bovine TLR4 ELISA Test Kit Toll-like Receptor 4 ELISA Assay Kit Customized Cat.No ...