Home Companies Delta Technology (Chongqing) Co., Ltd.

Three Phase Power Quality Analyzer, Power Quality Data Logger

Delta Technology (Chongqing) Co., Ltd.

Contact Us

[China] country

Trade Verify

Address: No.85 Zhong Shan Yi Road, Yu Zhong District, Chongqing, China. 400010

Contact name:Tina Chen

Inquir Now

Delta Technology (Chongqing) Co., Ltd.

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

Three Phase Power Quality Analyzer, Power Quality Data Logger

Country/Region china
City & Province chongqing chongqing
Categories Other Electric Power Tools
InquireNow

Product Details

Three Phase Power Quality Analyzer, Power Quality Data Logger

Introduction:
ETCR-5000 Three Phase Power Quality Analyzer, Power Quality Data Logger is specially designed for comprehensive analysis and diagnosis on all the voltage, current, power, power, harmonic, and phase electric parameters.
 

It applies to the electricity industry, petrochemical, metallurgy, railway, mining enterprises, scientific research institutions, and metrological department.
ETCR-5000 3 Phase Power Quality Analyzer Power Quality Data Logger is suitable for field tests of three phases, multi-functional and intelligent, concise man-machine operation.

Parameters:

Influence factorTest itemBase conditionWorking condition
Environment temperatureAll parameters(23±2)°C-10°C~ 40°C
Relative humidityAll parameters40%~ 60%<80%
Phase-to-neutral voltageAll parameters(100±1%)V1.0V~ 1000V
Phase-to-phase voltageTrue RMS phase-to-phase voltage(200±1%)V1.0V~ 2000V
CurrentTrue RMS current(5±1%)A10mA~ 1000A
Network frequencyAll parameters50Hz±0.1Hz40Hz~ 70Hz
Phase shiftActive power and active energyCosφ=1Cosφ: 0.2~ 1.0
Reactive power and reactive energySinφ=1Sinφ: 0.2~ 1.0
HarmonicAll parameters<0.1%0.0%~ 100%
Voltage unbalanceAll parameters<10%0.0%~ 100%
Working voltage of deviceAll parametersDC9.8V±0.1VDC9.5V~ 10.5V
External electric field,
magnetic field
All parametersShould be avoided
Test positionMeasured related parameters of currentTested wire at the center of clamp.
Power supplyRechargeable lithium-ion battery pack 9.6V, backup charger.
Battery indicatorBattery symbol shows dump energy. When the voltage is too low, automatic shutdown after 1 minute.
Power consumptionCurrent consumption of normal test 490 mA, continuous working for 8 hours.
Display modeLCD color screen, 640dots*480dots, 5.6 inches, display domain: 116mm*88mm.
Size of clamp008 small sharp current clamp: 7.5mm*13mm;
040 circle current clamp: 35mm*40mm;
068 circle current clamp: 68mm*68mm;
Instrument dimensionsL*W*H: 240mm*170mm*68 mm.
Number of channels4U/4I.
Phase-to phase voltage1.0V~2000V.
Phase-to-neutral voltage1.0V~1000V.
Current008 current clamp: 10mA~10.0A;
040 current clamp: 0.10A~100A;
068 current clamp: 1.0A~1000A;
Optional current transformer: instrument input current 1mA~500mA.
Frequency40Hz~70Hz.
Parameters of electricityW, VA, Var, PF, DPF, cosφ, tanφ.
Energy parametersWh, Varh, Vah.
HarmonicOrder 0~50.
Total harmonic distortionOrder 0~50, each phase.
Expert modeYes.
Number of Transient records150 sets.
Voltage flickerYes.
Starting current modeYes, 100 seconds.
3 phases unbalanceYes.
Record300 days(simultaneous recording 20 parameters, record one point every 5 seconds).
Min/Max recorded valueMeasurement of maximum and minimum values over a period of time.
Alarm40 different types of parameter selections, 12,800 sets alarm logs.
PeakYes.
Phasor diagram displayAutomatically.
Capacity of snapshots60.
Menu languageEnglish/Chinese.
CommunicationUSB.
Automatic switching offWhen an alarm campaign is initiated or a search for transients, an inrush current capture, or a trend recording is pending or in progress, the device is not automatic switching off.
In other test mode, 15 minutes without keystrokes, automatic shutdown after prompt 1 minute.
Backlight functionYes, suitable for use at night and dark place.
WeightHost: 1.6kg (with battery).
008 small sharp current clamp: 170g*4;
040 circle current clamp: 190g*4;
068 circle current clamp: 510g*4;
Test wires and power adapter: 900g;
Total weight: about 10.5kg (with packaging).
Length of voltage test wire3m.
Length of current sensor wire2m.
Working temperature and humidity-10°C~40°C; below 80%Rh.
Storage environment-10°C~60°C; below 70%Rh.
Input impedanceInput impedance of test voltage: 1MΩ.
Withstand voltageWithstand 3700V/50Hz sinusoidal AC voltage for 1 minute between instrument wiring and shell.
InsulationBetween instrument wiring and shell ≥10MΩ.
StructureDouble insulation, with insulation vibration-proof sheath.
Safely rulesIEC 61010 1000V Cat III / 600V CAT IV, IEC61010-031, IEC61326, Pollution degree: 2.
Packing Size400*270*270(mm) (L*W*H)
Weight8Kg

Functions:
Waveform real-time display (4 channels voltage/4 channels current).
True RMS values of voltages and currents.
The DC components of voltages.
Peak current and voltage values.
Minimum and maximum half-cycle RMS current and voltage values.
Phasor diagram display.
Measurement of each harmonic up to order 50.
Bar charts show harmonic ratios of current and voltage of each phase.
Total harmonic distortion (THD).
Active, reactive, apparent power, by phase and cumulative.
Active, reactive, apparent energy, by phase and cumulative.
Transformer K factor.
Power factors (PF) and displacement factors (DPF or COSΦ).
Short-term voltage flicker (PST).
Three phase unbalance(current and voltage).


Hot Products

SR-601 Generator Motor Waveform Curve Testing Digital Signal Recorder Introduction: SR-601 Signal ...
SR-601 Instantaneous Power Signal Recorder Power Data Logger Introduction: SR-601 Signal Recorder is ...
XDC-2 Handheld Lead Acid Battery Internal Resistance Tester Introduction: XDC-2 Handheld Lead Acid ...
XDC-2 Digital Battery Conductance Testing Battery Internal Resistance Meter Introduction: XDC-2 ...
Three Phase Power Quality Analyzer, Power Quality Data Logger Introduction: ETCR-5000 Three Phase ...
ETCR-5000 Three Phase Power Quality Analyzer and Power Quality Meter Introduction: ETCR-5000 Three ...