Scb10/Scb12/Scb13 Dry-type Epoxy Casting Distribution Power Transformer 50-2500kVA Core

Country/Region china
City & Province shandong
Categories Power Distribution Equipment
InquireNow

Product Details

Basic Info.

Model NO.
SCB10
Application
Power
Phase
Three
Core
Core-type Transformer
Cooling Method
Dry-type Transformer
Winding Type
Multi-winding Transformer
Certification
ISO9001, CCC
Frequency Characteristics
Power Frequency
Shape of Core
Ring
Trademark
Witry OEM
Transport Package
Wooden Case
Origin
Shandong China
HS Code
8504319000

Product Description

Dry type transformer Introduction

The coil is internally equipped with axial air passage, so as to improve the heat radiating condition; by adopting the scientific casting forming process, the resin is ensured to fully permeate between turns, layers and sections, so as to guarantee the electric insulation strength and less local layout (≤5 p c). The dry type transformer has the advantages that the resin thickness of packaging layer is reduced, and the heat radiating capability of coil is improved; the coil is reinforced by glass wire felt, so as to increase the mechanical strength of coil, enhance the sudden short-circuit withstand capability, and successfully solve the problem of cracking of casting body; the coil is made of special process, so as to greatly reduce the partial discharge amount in coil, and the electric strength of coil is improved; the LV coil adopts the foil structure, so as to reduce the magnetic leakage at end part, and enhance the sudden short-circuit withstand capability.

Application environment

1. Environment temperature (natural change values of surrounding air temperature)
Maximum air temperature: +40ºC
Average temperature of hottest month: +30ºC
Maximum yearly average temperature: +20ºC
Minimum air temperature: -25ºC (for outdoor transformer)
Minimum air temperature: -5ºC (for indoor transformer)
2.The altitude height of installation location shall not exceed 1000m. If exceeding 1000m, it's necessary to otherwise specify.
3 .The relative temperature of air is not higher than 93%. 
4 The installation place is free from gas, dirt and other explosive and corrosive mediums which severely affect the insulation of transformer .
5 The installation place is free from severe vibration and bump.


Technical Parameters of 6kV and 10kV Power Transformer with Off-circuit Tap Changing (Group A)
 
Rated Capacity 
(kVA)
Voltage Combination and Tapping RangeConnection SymbolNo-load Loss
(W)
Load Loss under Different Insulation Classes (W)No-load Current (%)Impedance Voltage (%)
HV (kV)HV Tapping Range (%)LV (kV)B (100C)F(120C)H(100C)
306
6.3
10
10.5
11
±5
±2X2. 5
0. 4Dyn11
Yyn0
2207107508002. 44. 0
50310990106011302. 4
804201370146015601. 8
1004501570167017801. 8
1255301840196021001. 6
160 ±5
±2X2.5
0. 4Dyn11
Yyn0
6102120225024101. 64. 0
2007002510268028701. 4
2508102750292031201. 4
3159903460367039301. 2
40011003970422045201. 2
50013104860517055301. 2
63015105850622066601. 0
63014605940631067501. 0
80017106930736078801. 0
100019908100861092101. 06. 0
12502350963010260109801. 0
160027601170012400132701. 0
200034001440015300163700. 8
250040001710018180194600. 8
160027601300013700146601. 08. 0
200034001590016900180000. 8
250040001880020000214000. 8

Technical Parameters of 6kV and 10kV Transformer with On-load Tap Changing

Rated Capacity 
(kVA)
Voltage Combination and Tapping RangeB (100C)No-load Loss
(W)
Load Loss under Different Insulation Classes (W)No-load Current (%)Impedance Voltage (%)
HV (kV)HV Tapping Range (%)LV (kV)
F(120C)H(100C) 
3156
6. 3
6. 6 10
10. 5 11
±4 X2. 50. 4Dyn11 Yyn011003600380041001. 44. 0
40012504250450048001. 4
50014405150550058501. 4
63016606100650069501. 2
63016006250670071001. 26. 0
80019007400790084001. 2
100022008700925099001. 0
125026001040011000118001. 0
160030301230013100140001. 0
200038001510016000171000. 8
250044001800019100204000. 8

For technical parameters of 35kV SCB10 power transformer,   35kV SCB10 series Dry type transformer

Production Introduction:


It is used for directly reducing the 35kV power grid supply into 400V power distribution supply or 10kV power distribution supply for supplying power for customers. It has advantages that it has been widely applied to many project because of obvious advantages; the land occupation area is reduced, the multi-stage power transformation construction is reduced, and the social benefits are obvious; the project investment is saved, and the economic benefit is improved; the 10kV power transmission and transformation procedure is reduced, so the running and maintenance cost is obviously reduced; the HV small current is used for replacing LV large current for power transmission, so the line loss is reduced, and the running cost is saved; the 35kV power source is directly accessed into the electric utilization center, so the power supply reliability is effectively improved.

Technical Parameters of 35kV Power Distribution Transformer with Off-circuit Tap Changing
 
Rated Capacity 
(kVA)
Voltage Combination and Tapping RangeConnection SymbolNo-load Loss
(kW)
Load Loss under Different Insulation Classes (W)No-load Current (%)Impedance Voltage (%)
HV (kV)HV Tapping Range (%)LV (kV)B
(100°C)
F
( 1 2 0C )
H
(100C )
50     B (100C)F(120C)H(100C)2. 86. 0
1007002080220023502. 4
1608802790296031701. 8
2009803300350037501. 8
25011003750400042801. 6
31513104480475050801. 6
40015305360570060801. 4
50018006670700074501. 4
63020707650810087001. 2
800240090009600102501. 2
100027001040011000118001. 0
125031501270013400143000. 9
160036001540016300174000. 9
200042501810019200205000. 9
250049502170023000246000. 9
Note: The load loss is the number calculated at the reference temperature in bracket (refer to GB1094.11).

 Technical Parameters of 35kV Transformer with Off-circuit Tap Changing
 
Rated Capacity 
(kVA)
Voltage Combination and Tapping RangeConnection SymbolNo-load Loss
(kW)
Load Loss under Different Insulation Classes (W)No-load Current (%)Impedance Voltage (%)
HV (kV)HV Tapping Range (%)LV (kV)B
(100°C)
F
(120°C)
H
(100°C)
80035~
38. 5
±5±2
X2.5
3.15
6
6.3
10
10.5
11
Dynll
Ydll YynO
250094009900106001. 16. 0
100029701080011500123001. 1
125034801280013600145001. 0
160041001540016300174001. 0
200047001810019200206000. 97. 0
250054002170023000246000. 9
315067002430025800275000. 88. 0
400078002940031000330000. 8
500093003470036800393000. 7
6300110004050043000459000. 7
8000126004570048500519000. 69. 0
10000144005550058500626000. 6
12500175006400068000727000. 5
16000215007550080000848000. 5
20000255008500090000963000. 410. 0

 Technical Parameters of 35kV Power Transformer with On-load Tap Changin
 
Rated Capacity 
(kVA)
Voltage Combination and Tapping RangeConnection SymbolNo-load Loss
(kW)
Load Loss under Different Insulation Classes (W)No-load Current (%)Impedance Voltage (%)
HV (kV)HV Tapping Range (%)LV (kV)B
(100°C)
F
(120°C)
H
(100°C)
200035-38. 5±5±2 X2. 56
6.3 10
10.5 11
Dynll Ydll50001890020000214000. 97. 0
250058002250023800255000. 9
315070002530026800287000. 8
400082003030032100344000. 8
500097003580038000406000. 78. 0
6300115004150044000470000. 7
8000132004720050000535000. 69. 0
10000151005680060200645000. 6
12500183006700070000760000. 5
16000225007760082400881000. 5
20000265008750092700992000. 410. 0
Note: The load loss is the number calculated at the reference temperature in bracket (refer to GB1094.11).

10kV SCB15 amorphous alloy dry type transformer  10kV SCB15 series  Dry type transformer

Production Introduction


It has the advantages of low no-load loss, no oil, flame retardance, self-extinguishing, moisture preventing, cracking preventing and no maintenance. The amorphous alloy dry type transformers can be applied to all places using the common dry type transformers, and now been widely applied to high-rise buildings, commercial centers, subways, airports, railway stations, industrial and mining enterprises and power generation plants. It is especially suitable for places with higher combustible, flammable and fireproof requirements.

Technical Parameters of 35kV Power Transformer with On-load Tap Changing
 
Rated Capacity 
(kVA)
Voltage Combination and Tapping RangeConnection SymbolNo-load Loss (kW)No-load Current (%)No-load Loss (kW)Impedance Voltage (%)
HV (kV)HV Tapping Range (%)LV (kV)
1006
6.3
10
10.5
11
±5±2
X 2. 5
0. 4Dyn11
Yyn0*
1301. 015704
1601700. 92130
2002000. 82530
2502300. 82760
3152800. 73270
4003100. 73990
5003600. 64880
6304200. 658806
8004800. 56960
10005500. 48130
12506500. 49690
16007600. 411730

Overall Dimension of 10kV SCBH15 Amorphous Alloy Dry type transformer
 
Model 
kVZ/kV
 Weight (kg)

 
LBHH1L2XL1

 
315/10143097012101095660 X 6601800
400/10143097013801265660 X 6602150
500/10165097012751130820 X 6602530
630/10173097014301240820 X 6603000
800/10192597014901215820 X 6603400
1000/10192597015201335820X 6604020
1250/101955107016051365820X 6604790
1600/1020501070178014551070X 6605780

About Our Company

Shandong Witry Electric Co., Ltd. is a professional electrical equipment enterprise located in Shandong province east of China, integrating R&D, design, manufacture, supply and export.

The main products are high-voltage transmission and transformation equipment, high and low-voltage switchgear, cable tray. the products are widely used in power, metallurgy, chemical industry, machinery, medicine, mining, textile and other industries.
 
 
Mission & Vision
Thinking and doing more,  make customers do less.
Being more efficient,  make customers more beneficial.
Represent with quality,  make reputation with service.
Sincerely treat guests,  make friends in business.

We are committed to producing only the highest quality products that meet or exceed our customers' expectations and requirements. Our goal is to achieve 100% customer satisfaction by delivering the best products and services on time and defect free. We will achieve this individually and corporately through tested and proven processes and controls in our Quality System, and with a constant focus and effort on continuous improvement.
 
 
Our Employees
Our employees consists of experienced, well-motivated and dedicated team of engineers, technicians, sales executives and management staff.

Our company has a strong technical team, all-weather provide convenient fast pre-sale and after-sale service and detailed engineering technical solutions.
 
Our Equipment and Management
Our factory covers an area of 100,000 square meters and has 18 workshops. The main equipment includes laser cutting machine, Shearing Machine, automatic ladder edge production line, high-voltage electrostatic powder spraying production line, etc. It has more than 100 sets of imported CNC processing equipment and precision testing equipment.

Each process has strict quality control and processing technology, and the products fully comply with national standards and IEC (International Electrotechnical Commission)standards. The company has successfully obtained ISO9001:2008 quality management system, ISO14001:2004 environmental management system and OHSAS18001:2007 occupational health and safety management system certification.

 



























































































Hot Products

Basic Info. Model NO. SCB10 Application Power Phase Three Core Core-type Transformer Cooling Method ...
Basic Info. Model NO. ZBW Application Power Phase Three Core Core-type Transformer Cooling Method ...
Basic Info. Model NO. SCB10 Application Power Phase Three Core Core-type Transformer Cooling Method ...
Basic Info. Model NO. ZBW Application Power Phase Three Core Core-type Transformer Cooling Method ...
Basic Info. Model NO. SCB10 Application Power Phase Three Core Core-type Transformer Cooling Method ...
Basic Info. Model NO. ZBW Application Power Phase Three Core Core-type Transformer Cooling Method ...