0.1-25 M ³ / Min Range Hood Performance Testing Equipment 3% Wind Measurement Error​

 

 

● Overview:
 

This device is applicable to the air performance test of the free air intake type (B type) ventilation

 

fan and the range hood. Its performance accords with the national standard GB / T 17713-2011

 

"Range Hood" and GB / T 14806 "Household and Similar Use Exchange ventilation fan and its

 

governor "requirement. This device is equivalent to the air performance test of the free-breathing

 

(Type B) ventilators in IEC 60665 "AC Ventilators and Their Governors for Household and Similar

 

Purposes" of the International Electrotechnical Commission.
 

 

● Test principle:
 

By measuring the gas flow through the orifice plate after the static pressure reducing cylinder,

 

converted to air volume. In the experiment, the air pressure was measured by changing the

 

diameter of the orifice plate, and the air performance curve of the hood or the fan was obtained

 

through the computer data processing.
 

 

● Test items
 

The maximum static pressure (zero air volume static pressure value), the maximum air volume

 

(zero static pressure air volume value), the provisions of the air volume static pressure, the

 

provisions of the air flow when the main motor input power, the provisions of the air volume of the

 

total pressure efficiency η% .
 

 

● technical indicators
 

① air volume measurement range 0.1-25m ³ / min;
 

② cylinder static pressure measurement range 0-500Pa;
 

③ wind measurement error ± 3%.

 

Hot Products

Laboratory Range Hood Performance Testing Equipment For Odour Reduction Factor ​ This laboratory is ...
0.1-25 M ³ / Min Range Hood Performance Testing Equipment 3% Wind Measurement Error​ ● Overview: ...
Household Range Hood Performance Testing Equipment 1500Pa For Air Duct ​ Overview: This device is ...
1KW Range Hood Performance Testing Equipment 25M / S Speed GB / T 13380 Standard​ Overview: The ...
Range Hood Performance Testing Equipment , Vacuum Cleaner Air Flow Test Equipment​ Overview This ...
Resistive Load Bank Pure Resistance Power Load Control Cabinet 50Hz - 60Hz​ ● Overview: Normally on...