Nuoxing Cable Co., Ltd |
|
4 Core 5 Core Aluminium Power Cable Electrical Armoured Cable Underground
Implementation standard:
GB/T 12706-2002 (equivalent to IEC502), flame retardant and
fire-resistant cable also conforms to IE332-3, IEC331, and can also
be produced according to the technical requirements requested by
users.
1, use: This product is suitable for AC 50HZ, rated voltage 0.6/1KV
transmission and distribution lines.
2, product standards: GB12706-2-91 rated voltage 35KV and below
copper core, aluminum core plastic insulated power cable, PVC
insulated cable
3, the use of characteristics: 1) the maximum rated temperature of
the cable conductor is 70 ℃. (2) short circuit (the longest
duration of not more than 5S), the maximum temperature of the cable
conductor does not exceed 160 ℃. (3) The ambient temperature of the
cable is not less than 0℃ when it is laid, and the minimum bending
radius is not less than 10 times the outer diameter of the cable.
NAYBY polyvinyl chloride insulated steel belt armored PVC sheathed cable is laid underground and can withstand external mechanical force.
Construction:
VV22/VLV22-0.6/1-kV-single core
1. Conductor: copper or aluminum, Class 1: solid conductor, or
Class 2: stranded conductor
2. Insulation: Polyvinyl chloride PVC
3. Inner sheath: PVC
4. Armor: steel tape
5. Sheath: PVC
Specificaiton:
Product name | Armoured Electrical Cable |
Certifications | CE/CCC/ISO |
Standard | IEC60502-1 |
Rated Voltage | 0.6/1 KV |
Conductor material | Copper/Aluminum |
Insulation Material | XLPE/PVC |
Armoured Material | None/Steel Tape/Steel wire |
Jacket Material | PVC |
Number of cores | 1C,2C,3C,4C,5C,3+1C,3+2C,4+1C |
Section area | 1.5MM2 - 400MM2 |
Extended information:
During storage, the cable should be packed in a standardized
manner, avoid long-term open-air exposure, and both ends should be
sealed reliably. Long-term storage in a humid environment is not
allowed, and the cable tray should not be stored flat. The height
of the tray should be considered and fixed effectively during
transportation. Multiple pallets are not allowed to be lifted at
the same time when lifting, and pushing down from high places is
strictly prohibited.
Special tools should be used for cable laying, such as cable release frame, guide roller, etc., to prevent mechanical damage during laying and keep away from heat sources. When laying cables through pipes, the inner diameter of the pipes should not be less than 1.5 times the outer diameter of the cables. When multiple cables pass through the pipeline, it is prohibited to squeeze the cables. The total area of the cable should not exceed 40% of the total area of the pipe.
Armoured Electrical Cable