Product Details

2p 40 Amp Mcb IEC60898-1 230/400V 50/60 Hz 1A-63amp Circuit Breaker

 

General:

Product Name:

Miniature Circuit Breaker / MCB

Type:

Mini

Rated Short Circuit Capacity lcu (V)

B,C,D

Rated Voltage:

230V/400VAC

Rated Current:

1A, 2A, 3A, 4A, 6A, 10A, 16A, 20A, 25A, 32A, 40A, 50A, 63A

Breaking Capacity:

6KA

Rated Frequency:

50/60Hz

Number of Poles:

1P, 1P+N, 2P, 3P, 3P+N, 4P

Altitude:

≤2000m

Ambience Temperature:

-5~40℃

Standard:

IEC/EN 60898-1

Protection Type:

overload protection,short circuit protection

Tripping Type:

thermal type

Installment:

TH 35mm din rail

Wiring Capacity:

≤25mm²

Application:

Short-circuit protection,Isolation function,Overload protection

 

 

 

Instantaneous tripping characteristic:

Circuit breaker PB8 are designed for protection of distribution and branch circuits, having different load;

 ♦ Curve B----Device should not work in 0.1 second at current 3 In; at current 5 In should work in less than 0.1S

 ♦ Curve C---- Device should not work in 0.1 second at current 5 In; at current 10 In should work in less than 0.1S

 ♦ Curve D---- Device should not work in 0.1 second at current 10 In; at current 20 In should work in less than 0.1S

 

 Over-current operating characteristics:

No.Rated current of release (A)Initial stateTest currentSpecified timeResult to be obtainedRemarks
11~63code state1.13 Int ≤ 1hNon-trip 
21~63upon the previous test1.45 Int < 1htripsetting current up to specified value steadily in 5s
3In ≤ 32code state2.55 In1s <t <60strip 
In > 32code state2.55 In1s <t <120strip 
41~63code state3 Int ≤0.1sNon-tripB type
1~63code state5 Int <0.1stripB type
1~63code state5 Int ≤0.1sNon-tripC type
1~63code state10 Int <0.1stripC type
1~63code state10 Int ≤0.1sNon-tripD type
1~63code state20 Int <0.1stripD type

 

 

The Number of Poles:

 

Dimensions:

 

Specifications: 

Rated current(A) In1-63
Rated frequency(Hz)50/60
Rated working voltage(V) Ue1P:230/400~, 2/3/4P: 400~
Rated insulated voltage(V) Ui500
Impulse withstand voltage(KV) Uimp6
Rated short-circuit breaking capacity(KA) Icn6
Instantaneous tripping typeB,C,D
Maximum working voltage Umax440
Minimum working voltage Umin12
Dielectric test voltage (kv)2
Service life Mechanical standard value10000
(O-C) Electrical Standard value4000
Connection and installation:
Protection degree All sidesIP40
Connection terminalIP20
Wire(㎟)16
Busbar(㎟)25
MountingCable/Busbar
Pollution degree2
Reference temperature for setting of thermal element(℃)30
Storage temperature(℃)-25℃~+70℃
Tightening torque3.0
ConnectionTop and Bottom
Dimensions(mm)                                                         a(1P/2P/3P/4P)17.5/35/52.5/70
                                                                                                                                       b(1P/2P/3P/4P)87/87/87/87
(WxHxL)                                                                      c(1P/2P/3P/4P)77.5/77.5/77.5/77.5

 

 

 

Certificates:



Packing and Delivery:




Why Choose Us:
---------------------------------------------
a. Reply your inquiry in 24 working hours.
b. Technical and professional guidance.
c. Best quality and best price.
We maintain excellent products and strive for 100% customer satisfaction. A good feedback is very important, we welcome for your kind suggestion or feedback on goods and our service.



FAQ:
1. Could I have prices of your products?
Well welcome. Please feel free to send us any inquiry. You will get our reply in 24 hours.
2. Can we print our logo/website/company name on products?
Yes, OEM and ODM are available.
3. What's the lead time for regular order?
7-15 days for order quantity less than 2000pcs. For more quantity, we can negotiate about it.
4. Do you inspect the finished products?
Our products 100% self-inspection and testing before packing.
5. How about payment terms?
30% deposit, the rest payment balance against B/L copy.

Hot Products

2 Poles Miniature Circuit Breaker 63amp Din Rail MCB With CE RoHs General: Circuit breaker is a kind ...
Circuit Protection breakers MCB 1P+N 40amp 4Kv Mini circuit breaker Application: ♦ Short-circuit ...
2p 40 Amp Mcb IEC60898-1 230/400V 50/60 Hz 1A-63amp Circuit Breaker General: Product Name: Miniature ...
YOKG TXM Series Electrical Db Distribution Box Circuit Enclosure Box General: Overall panel design ...
OEM Electrical Distribution Box 10 Way 14way 18 Ways 22 Way Din Rail Type Technical parameter: Model ...
YOKG Flush Triple Phase Electrical Boxes Power Distribution Equipment In 6 Way Technical parameter: ...