Home Companies Guangdong EuroKlimat Air-Conditioning & Refrigeration Co., Ltd

R410A Refrigerant 357KW DC Inverter VRF AC Unit

Guangdong EuroKlimat Air-Conditioning & Refrigeration Co., Ltd
Active Member

Contact Us

[China] country

Address: Euroklimat Industrial Park, Huangjiang Dongguan Guangdong China 523766

Contact name:LENG Zhengliang

Inquir Now

Guangdong EuroKlimat Air-Conditioning & Refrigeration Co., Ltd

R410A Refrigerant 357KW DC Inverter VRF AC Unit

Country/Region china
City & Province dongguan guangdong
InquireNow

Product Details

 

DC Inverter VRF Air Conditioner R410A 14 kW~357 kW

 

Condensing Unit Cooling Capacity : 14KW-357KW

Indoor Unit Type : Ceilling Concealed Ducted Type, High ESP Ducted Type , Fresh Air Duct Type , Wall Mounted Type ,4 Way Cassette type,1 Way Cassette type,2 Way Cassette,Ceiling/standing type.

Indoor Unit Cooling Capacity :1HP~32HP

 

Description:

 

 

Higher Energy Efficiency

 

By using a PWM valve to control the time ratio of unloading and loading status, the DC inverter scroll compressor can continuously regulate the capacity within a range of 10%–100%, increasing the precision of capacity regulation and the stability of indoor temperature.

 

Low Energy Consumption

 

The unit boasts an outstanding IPLV(C) (refrigerating coefficient of performance). The full series of units features an IPLV(C) that is far higher than China national standard energy efficiency level 1st.

 

More Advanced Technologies

 

Quick Start Technologies

 

EKRV series DC Inverter multi-connected central air conditioners can run in full load within a short period, quickly meeting indoor requirements.

 

Supercooling Technologies

 

Enlarges the condenser of the outdoor unit to implement level-1 supercooling, and then uses an efficient supercooler to implement level-2 supercooling, reaching a total supercooling degree of 19.6°C. Enhances the cooling capability of the unit and improves the efficiency of the unit. Reduces the pressure loss when the refrigerant is circulated in the pipe, rationally allocating the ultra-long accessory pipe and refrigerant.

 

DC inverter motor

 

Fans of outdoor units can be regulated at 32 levels based on load changes, improving efficiency and reducing noise.

 

The unit can safely run under partial load for a long time.

 

Intelligent Defrosting Technologies;

 

Wide operation range

 

EKRV series digital multi-connected central air-conditioning units can generate cooling result in ambient temperature of 55°C.

 

Ultra-long Connecting Pipe

 

Total pipe length

1000m

Max. equivalent length of a single pipe

220m

Max. actual length of a single pipe

190m

Max. vertical span between outdoor and indoor units

110m

Max. vertical span between indoor units

40m

 

Easy Installation

 

The system can provide an external static pressure of 50 Pa, ensuring the heat dissipation result of the outdoor unit under the same installation conditions (optional).

A higher external static pressure ensures that the outdoor unit can be flexibly installed at a rooftop, compartment, balcony, or equipment floor, preventing overload of the unit due to poor ventilation

 

More Secure

 

Dual Backup Operation with Guaranteed Security

Automatic Fault Diagnosis

Technologies for Automatic Identification of Pipe Length

Multiple Measures to Effectively Protect Compressors

Door Card Function (Optional)

Intelligent and Balanced Operation Management

 

Electronic expansion valve

 

The unit uses an electronic expansion valve with 4000-step capacity regulation to increase the precision of superheat degree control (liquid level control), enhance the operation security, and improve energy saving.

 

More Intelligent

 

Centralized Monitoring Software

 

One set of EKRV centralized monitoring software can control up to 2048 indoor units, meeting customers' requirements for large-scale centralized management.

 

Separate Control Charging per Customer

 

The unit can fairly and rationally divide the electricity quantity based on the model, operation mode, operation time, air supply/ return efficiency, and refrigerant flow of the air conditioning unit to protect the rights and interests of all owners. The unit provides customers with functions such as owner management, price and recharge management, energy saving management.

 

Centralized Control

 

Models of indoor units are diverse for selection.

 

Indoor units cover 6 series and 63 capacity types, and total fresh air indoor units are available, fully meeting customer requirements.

 

More Environment-friendly

 

Full Compliance with RoHS Directive,

Environment-friendly Refrigerant,

Automatic Refrigerant Recovery Technologies,

Automatic Determination of Refrigerant Charge,

Energy Consumption of 5 W in Standby Mode(a Record Low in the Industry)

 

Applications

 

hotels,entertainment centers, hospitals, restaurants, office buildings, cinemas,

factories, school supermarkets and so on.

 

Specifications

 

ModelEKRV080ER1EKRV100ER1EKRV120ER1EKRV140ER1EKRV160ER1EKRV180ER1EKRV200ER1EKRV220ER1EKRV240ER1
CapacityHP81012141618202224
Power supply380-415V/3N~/50Hz
Rated cooling capacitykW25.2283440455156.56268
Rated heating capacitykW2831.537.54550.557636975
Rated power of coolingkW5.856.98.6210.3712.2213.5515.0316.5517.24
Rated power of heatingkW5.977.078.9610.7212.2513.6215.1216.7617.92
Rated current of coolingA11.313.416.420.223.325.828.631.432.7
Rated current of heatingA11.413.717.120.423.325.928.731.834
Max working currentA22.524.925.839.140.345.247.148.651.6
Liquid pipemm (inch)9.5212.715.88
Gas pipemm (inch)19.0522.2325.428.6
Pipe connectionLiquid pipeConnecting bell-mouthed terminal with threaded joint
Gas pipeConnecting bell-mouthed terminal with threaded jointWelding
Unit weightkg205215235315325345355365370
Sound leveldB(A)565760606061616162
RefrigerantR410A
Dimensions (W x D x H)(mm)920×760×16401140×835×16401655×835×1640

 

ModelEKRV260ER1EKRV280ER1EKRV300ER1EKRV320ER1EKRV340ER1EKRV360ER1EKRV380ER1EKRV400ER1EKRV420ER1
CapacityHP262830323436384042
Power supply380-415V/3N~/50Hz
Rated cooling capacitykW747985.29096102108114119
Rated heating capacitykW82.58895100.5107.5114120127.5133
Rated power of coolingkW18.9920.8422.423.4525.7727.127.6129.3631.21
Rated powerkW19.6821.2122.7323.8325.8727.2428.6430.431.93
of heating
Rated current of coolingA3639.542.544.548.951.452.455.759.2
Rated current of heatingA37.340.243.145.249.151.754.357.760.6
Max workingA64.966.171.173.575.578.585.59092.5
current
Liquid pipemm19.05
Gas pipemm31.838.1
Pipe connection modeLiquid pipeConnecting bell-mouthed terminal with threaded joint
Gas pipeWelding
Unit weightkg480485510515545550575580585
Sound leveldB(A)626263636363636364
RefrigerantR410A
Dimensions (W x D x H) 1780×835×16402615×835×1640
(mm)

 

 

 

 

 

Hot Products

EKCC 010A - EKCC 015A low static pressure central duct type air conditioner Specifications: Model ...
EKCC 020A - EKCC 025A low static pressure central duct type air conditioner Specifications: Model ...
25 kW EKDB100A(R) high static pressure duct type air conditioning unit Specifications: Unit model ...
Commercial Office Application Water Cooled VRF Air Conditiner Outdoor unit range :22.5kW~80kW Indoor ...
DC Inverter VRF Air Conditioner R410A 14 kW~357 kW Condensing Unit Cooling Capacity : 14KW-357KW ...
Ceiling Concealed VRF Indoor Unit Cooling Capacity 1.8~16kW 19 Models Multiple air return modes ...