66-220kV XLPE insulation power cable

Shandong Green  World International Trading Co., Ltd.
Active Member

Contact Us

[China] country

Address: 1107B Huidong Building, Wenhua East Road, Shandong, China

Contact name:Li Zheng

Inquir Now

Shandong Green World International Trading Co., Ltd.

66-220kV XLPE insulation power cable

Country/Region china
City & Province shandong
Categories Power Cables
InquireNow

Product Details

 

1.         Standard:

Voltage level(kV)

Standard

66

IEC60840

110

IEC60840 GB/T11017-2002

220

IEC62067 GB/Z18890-2002

2.        Product model and name:

1.        YJLW02(YJLLW02) -copper core(Al. Core) XLPE insulation aluminium sheath PVC aluminium sheath PVC sheath power cable

2.         YJLW03(YJLLW03) -copper core(Al. Core) XLPE insulation aluminium sheath PVC sheath power cable

3.        YJLW02-Z(YJLLW02-Z) -copper core(Al. Core) XLPE insulation aluminium sheath PVC sheath longitudinal resistance power cable

4.        YJLW03-Z(YJLLW03-Z) -copper core(Al. Core) XLPE insulation aluminium sheath PVC sheath longitudinal resistance hydro power cable

5.        Note: besides antiflaming-type power cable; low smoke zero halogen power cable; low smoke low halogen power cable; anti white ant power cable and so on.

 

3.        The construction of power cable:

1.        Conductor core(800mm and below is press circle; 800mm above is segment);

2.        Conductor shielding layer(including Semi conductive bag belt layer);

3.        XLPE insulation layer;

4.        Insulation shielding layer;

5.        The longitudinal resistance water buffer layer;

6.        Wrinkle aluminium sheath(with coating);

7.        PVC or XLPE protection layer or semi-conductor layer;

 

4.        Use of characteristics and using the environment

1.        The maximum working temperature of conductor is 90℃( the longest time is less than 5s); the maximum temperature is less than 250℃;

2.        The maximum allowable side pressure of cable is 5kN/m;

3.        The maximum allowable drag intensity of cable: copper conductor70N/mm2; aluminium conductor 40 N/mm2;

4.        The arrangement temperature of cable is not less than 0℃; the minimum bending radius is not less than 20 times cable OD;

5.        PVC Outer sheath cable is mainly usable for antiflaming demand and insulation requirement. PE outher sheath cable is mainly usable for direct buried installation with high insulation demand and moist environment.

Hot Products

1. The main characteristics: The product has the good quality of light weight, easy construction, ...
This product is suitable for circuit with 50HZ, 0.6/1kv rated voltage. It can be used to transmit ...
1. Standard: Voltage level(kV) Standard 66 IEC60840 110 IEC60840 GB/T11017-2002 220 IEC62067 GB...
1. Standard: IEC60502-2008 2. Usage characteristic: The cable conductor can run in the maximum ...
HV shunt capacitor is shunt connected with AC power electric system PF (50Hz or 60Hz) equals and ...
Application TK-TBB series HV shunt capacitor complete installations apply to 6KV, 10KV, 20KV, 35KV, ...