Home Companies Sichuan Baikong Electric Technology Co., Ltd.

Single Phase EPS Centralized Power Supply Panel For Fire Emergency Lighting

Sichuan Baikong Electric Technology Co., Ltd.
Active Member

Contact Us

[China] country

Address: D5-4 Workshop 389 3rd Section, East third Ring Road, Industrial Development Zone ,Pengzhou City, Sichuan Province

Contact name:admin

Inquir Now

Sichuan Baikong Electric Technology Co., Ltd.

Single Phase EPS Centralized Power Supply Panel For Fire Emergency Lighting

Country/Region china
City & Province sichuan
Categories Switching Power Supply
InquireNow

Product Details

Single-Phase Centralized Control Centralized Power Supply For Fire Emergency Lighting

 

 

Product Overview

 

The main components of the company EPS include: battery pack, IPM intelligent module, charger, master control panel, LCD (ICD) display current / voltage / temperature detection circuit, interlock switching circuit, alarm circuit, etc.

 

The EPS can be civil air defense channels, underground facilities, hospitals, operating rooms, government organs, large supermarkets, shopping malls and schools.Square, stations, parks, sports venues, convention and exhibition center securities trading halls and other public places to provide fire emergency lighting power, as well as emergency power power for elevators, spray pumps, curtain doors, water pumps, fans, monitoring devices, military radar, on-board mobile sources, system and other equipment of financial institutions.

 

 

Model Meaning

 

DKW
EPS Single-Phase (Lighting) Emergency Power SupplyPower Rating (KW)

 

 

Product Profile

 

  • Capacity: 0.5KW~2KW (hanging, embedded, landing), 3KW~15KIW (landing).
  • Use: Provide emergency power supply for 220V electrical appliances and equipment such as fire emergency lighting load or other loads.
  • Specifications: 0.5,1,1.5,2,3,4,5,6,7,8,9,10,15KW, etc.
  • Installation form: mounted or embedded (external battery cabinet).
  • Standby Time: 30 minutes / 60 minutes / 90 minutes (standard type) / 120 minutes, and the standby time can be configured according to the design requirements.

 

 

Qualification

 

 Model(0.5kw~3kw)        (4kw~15kw)
InputCity Power Voltage220v±15% (It Can Be Set Up On Customer Request)
Power Frequency50hz±5%
Input CurrentonInput The Current Standard Value Of x1.2 x
Direct Voltage48v 192v

Double Road

Mutual Investment

(It Can Be Added According To

The Customer Design Requirements)

OutputOutput VoltageNormal State: Consistent With The Municipal Electricity
Emergency Status: 220v ± 3%
Output FrequencyNormal State: Consistent With The Municipal Electricity
Emergency Status: 50hz ±, 5%
Output Loop

Three Roads (Which Can Be Added According

To Customer Design Requirements}

Outputs The Loop TypeContinuous, Non-Sustainable, Fire Control Linkage Type
 ProductivenessEmergency Time 90%, Municipal Power Power Supply 100%
 Discharge WaveformPure Sine Wave
 Switching Time≤3秒(It Can Be Specially Customized For 100 Ms Or 0 Ms)
 Overloading CharacteristicNormal 60 Seconds At 120%; 30 Seconds At 150%
 Stand-By Time90 Minutes (Configurable According To Customer Request)
 Storage BatteryValve-Free Lead-Acid Battery
 Defencive Function

Over-Temperature, Short-Circuit, Over-Pressure,

Over-Current Protection

 Situation DisplayLarge-Screen Lcd Lcd Display
 CI

Rs485 / Rs232, Communication Protocol: Modbus

(Customer Selection Item)

 NoiseNormal State: No Noise, Emergency State: w55db
 Ambient Temperature-25°c~40℃
 Relative Humidity10-90%
 Altitude≤2000m;Power Reduction Shall Be Used At 2000m
 Adapt To Load

Suitable For a Variety Of Single-Phase And Lighting

Class Negative Planting

 

 

Size

 

TsOutput Power KwAppearance Size (Mm) Wide x x Deep x HighWeight(Kg)Install
0.5kw0.5500x250x80075Nested
1kw1.0500x250x800130Hang Type
1.5kw1.5600x400x1200210 
2kw2.0600x400x1200230 
3kw3.0600x400x1200360 
4kw4.0700 x450x 1500460 
5kw5.0700x450x1500590Floor Type
6kw6.0700 x450x 1500750 
7kw7.0800x600x2000900 
8kw8.0800x600x20001000 
9kw9.0800x600x20001100 
10kw10.0800x600x20001200 

 

 

All model specifications and sizes can be ordered according to customer request.

 

 

 

When Used For Emergency Lighting, Eps Line And Type, Switch Wiring

 

Output

Line

Code

InstructionMode Of Connection
l

Municipal Power Has Output, No Municipal Power Has Output

(With Emergency Power Supply)

i(Continuous Output)
l1

There Is No Output Of Market Power,

No Market Power Transmission

(There Is Emergency Power Supply)

Ii (Nonsustainable Output)
l2

Municipal Power Has Output, No Market Power, No Output

(No Emergency Power Supply)

Iii (General Distribution Output)
l3

When There Is Municipal Power, There Is No Municipal Power,

And No Municipal Electricity Is Controlled

By Fire Control Linkage Output

Iv (Fire Linkage Output)
l4

Normal No Output, Emergency

By The Fire Linkage Control Output

v(Fire Linkage Output)
n  
Pe  

 

 

Attended Mode

 

 

Note; L1, L2, L3 are not available in each EPS but made according to the design requirements.

Hot Products

Product Overview: Single-phase/three-phase EPS emergency power supply adopts backup mode of work, ...
Single-Phase Centralized Control Centralized Power Supply For Fire Emergency Lighting Product ...
28-12 High-Voltage Reactive Power Compensation Device Switch Cabinet Product name: 28-12 high...
Stainless steel outdoor intelligent integrated distribution box cable branch box distribution ...
10kV Built-In Outdoor Armoured Switch Cabinet Schematic diagram of the switchgear structure A,Bus ...
40.5kV Assembly Type Three Phase Current Integrated Distribution Cabinet Product Name: 40.5kV ...