Home Companies Sichuan Baikong Electric Technology Co., Ltd.

600A 230V 400V MCCB 100 Amp 3 Pole Power Circuit Breaker Heat Resistant

Sichuan Baikong Electric Technology Co., Ltd.
Active Member

Contact Us

[China] country

Address: D5-4 Workshop 389 3rd Section, East third Ring Road, Industrial Development Zone ,Pengzhou City, Sichuan Province

Contact name:admin

Inquir Now

Sichuan Baikong Electric Technology Co., Ltd.

600A 230V 400V MCCB 100 Amp 3 Pole Power Circuit Breaker Heat Resistant

Country/Region china
City & Province sichuan
Categories Battery Chargers
InquireNow

Product Details

100A/600A 230V/400V MCCB power circuit breaker Performance Heat Resistant

 

 

Application

ZMM10 series molded case circuit breaker (hereinafterreferred to as circuit breaker) is suitable for distributingnetwork of AC 50Hz (or 60Hz), rated current 15~600A,ated insulation voltage 690V and rated working voltage400V or below. It can be used to distribute electric energy and protect the circuit and electric equipment againstoverload, short circuit and under voltage, under normalcondition, the circuit breaker also can be used tswitchthe circuit infrequently. Circuit breakers of frame size250A and below also can be used to protect motor orinfrequently start motor.

The products are in conformity with GB 14048.2, GB 14048.4, IEC 60947-2 and IEC 60947-4.

 

 

 

 

Main Technical Data

1.Main technical parameters of circuit breaker

 

 

TypeRated frame currentRated currentPower lossRated Service short-circuit breaking capabilityRated Ultimate short-circuit breaking capabilitymm Flashover distance
lcs kACOSlcs kACOS
ZMM10 -10010015,20,25,30,
40,50,60.80,100
2550.5100.3200
ZMM10 -250250100,120(125),140(150),170,200(225),25055100.3200.25200
ZMM10 -600600200,250,300,350,
400,500,600
13012.50.3250.25250

 

2.Main technical parameters of control circuit

 

 

SortRated Working Voltage
AC 50HzDC
ReleaseShunt releaseUs230, 40024, 110, 220
Under voltage releaseUe230, 400-
Electric mechanismUs230, 400-

 

3.Main technical parameters of auxiliary contact

 

 

Conventional thermal currentRated insulation VoitageRated working currentRated frame current
AC400VDC220V
34000.260.15225A
0.40.2400A

 

4.Setting value of short-circuit protection current

 

 

Typelest current for distribution protectionTest current for motor protectionAccuracy of setting valueConventional timeIntiap state
ZMM10-100,25010ln12ln±20%<0.2 TripCold state
ZMM10-600-

 

5.Inverse time lag breaking characteristics of circuit breaker for distribution protection

 

 

Name of test currentCurrent setting multipleConventional timeIntiap stateAmbient temperature
1.01ln≤100A63A<In≤225A225A<ln
Conventional non-tripping current1.05ln≥lh≥2hCold state+30
Conventional tripping current1.30ln<1h<2hHot state
Returnable time3.0lnReturnable timeCold state
5s8s12s

 

6.Inverse time lag characteristics of circuit breaker for motor protection

 

 

Name of test currentCurrent setting multipleConventional timeIntiap stateAmbient temperature
1.01ln≤100A100A<ln≤250A
Conventional non-tripping current1.01 In≥2hCold state+40℃
Conventional tripping current1.2ln<2hHot state
1.5ln≥2min≤4minHot state
Current of returning characteristic7.2ln2s<t≤10s4s<t≤10sCold state

 

 

 

External And Installation Size

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

advantage

 

Our MCCBs provide you unmatched circuit protection in alternative energy, commercial, industrial, mining, and military applications when protecting conductors against overloads and short circuits.

These circuit breakers are applied in panelboards, switchboards, motor control centers, control panels, combination starters, individual enclosures, and bus duct plug-in units.

The breakers according to the rated maximal value to short- circuit breaking ability (Icu), would be classified four kinds types C (basic type), L (typica1 type), M (second high breaking type) and H (high breaking type). The breakers are of the following characteristics: compact size, high breaking ability, short arc-over distance (some of the "0" arc-over distance) and shake proof. They also undergo the tests of nuclear industry conditions (1E grade) and ship conditions, and become the only product using in nuclear industry base among the same products made in the country, further more become the ideal products applied on land or ships.

 

 

Matters need attention

 

Normally, we will provide the most suitable shipment method for you. If the quantity is few, the goods will be sent by express when the payment is clear. Also, we can transport the goods by air or by sea, just according to your demand

 

 

profile

 

Baikong electric was born and developed wellSichuan Baikong Electrical Technology Co., Ltd is a complete set of high and low voltage power distribution equipment automation equipment, set production, research and development and sales Import and export services and other integrated enterprises, the company is headquartered in Pengzhou Industrial Park, Chengdu City.The company's main products are box-type substation Medium and high voltage power transmission and distribution equipment, low voltage power distribution equipment, fire electrical equipment, intelligent industrial electrical equipment, new energy and energy storage electrical equipment, metering and protection power distribution equipment, high and low voltage complete switchgear, high voltage ring network cabinet, cable branch box,SF6 inflatable cabinet, etc.

Hot Products

6A/100A Series Earth Leakage Circuit Breaker MCCB Circuit Breaker Heat Resistant Application DZ15LE ...
100A/600A 230V/400V MCCB power circuit breaker Performance Heat Resistant Application ZMM10 series ...
6A/100A 230V/400V MCCB Performance Heat Resistant Application DZ15 series molded case circuit ...
AC 690V,50/60HZ, 10~1250A Moulded Case Circuit Breaker MCCB Circuit Breaker 1.1 Certificates: KEMA, ...
ZW7-40.5/1250A outdoor vacuum circuit breaker power station type product information Product name: ...
63A/300A 230V/400V Heat Resistant MCCB Circuit Breaker Our MCCBs provide you unmatched circuit ...