Home Companies Xi'an Desun Uniwill Electronic Technology Co., Ltd.

DS206 Blue Green Algae Probe MODBUS Protocol Water Quality Monitoring Sensor

Xi'an Desun Uniwill Electronic Technology Co., Ltd.

Contact Us

[China] country

Trade Verify

Address: Room 502, Unit 2, Building 1, Yi Cui yuan i city, No. 11, Tangyan South Road, Yanta District, Xi'an city, Shaanxi Province, China.

Contact name:Wang

Inquir Now

Xi'an Desun Uniwill Electronic Technology Co., Ltd.

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

DS206 Blue Green Algae Probe MODBUS Protocol Water Quality Monitoring Sensor

Country/Region china
City & Province Shaanxi
Categories Other Electric Power Tools
InquireNow

Product Details

DS206Fluorescent blue-green algae sensor for water quality monitoring in rivers and lakes RS485, MODBUS protocol 

Introduction

The online blue-green algae sensor uses the principle of fluorescence method, which is more efficient and faster than the traditional manua counting method, and can be monitored in real time online. The senso has better repeatability and stability. With automatic cleaning brush, it can eliminate air bubbles and reduce the impact of contamination on the measurement, make the maintenance cycle longer, and maintain excellen stability for long-term online use It can play an early warning role on algae reproduction.
 

Features

★ Digital sensor, RS-485 output, support MODBUS

★ With automatic cleaning brush to prevent contamination and eliminate air bubbles

★ Direct measurement, simpler than traditional manual counting method

★ Continuous online monitoring, real-time control of water quality dynamics

 

Technical parameter

Product nameBlue-green Algae Sensor
modelDS206
principleFluorescence method
Range0-270, 000 cells/mL
Detection limit300 cells/mL
Resolution1 cells/mL
LinearityR2>0.99
temperature range0~ 50°C
Protection levelIp68
Sensor interfaceSupport RS-485, MODBUS protocol
InstallationInput type,
Power informationDC 5~12V, current <50mA
sizeΦ45*175.8mm
Probe cable length10 meters (default), can be customized
Housing materialSS316
Self-cleaning systemHave

 

Calibration instructions

 

1,Calibration of blue-green algae sensors: The blue-green algae sensor software (see the modbus manual) supports 2-point calibration. The more common environmental research dye, rhodamine B, can be used in sensor calibration.

2,Preparation

  • First take 0.1g of rhodamine B solution into 1000mL reagent bottle A, then add DI water or distilled water to 1000mL and shake well.
  • Take 1mL of the above solution into 1000mL reagent bottle B, and then add DI water or distilled water to 1000mL and shake well. The solution concentration of reagent bottle B is 100 ppb.
  • The prepared solution should be used within 24 hours.

3,Use

Rhodamine B shows that the fluorescence intensity is inversely proportional to temperature. Use 100 ppb rhodamine B standard solution. To properly set the sensor to ensure the sensitivity of algae blue-green algae at 20 ° C, enter the calibration value according to the temperature standard corresponding to the table below. (The table below shows algae blue-green algae as a function of temperature approximately equal to 100 ppb rhodamine B)

 

Temp, cells/ml
2654600
2752471
2851376
2949670
3047641
3145276
3243258
3340711
3438905
3537298
3634875
3733370

Note: The calibration using rhodamine B standard solution is only an approximate value. To ensure accurate readings, the fluorescence readings obtained on site must be linked to the results obtained from the extraction analysis of the above samples. Yushan used Rhodamine B (Item # 70301027) from Keystone.

Warning: Rhodamine B is listed as a substance that may cause carcinogenesis / induction of organism mutations. Gloves must be worn during operation.

Maintenance methods and common problems Maintenance schedule and method

I. Maintenance schedule

Online blue-green algae sensor with automatic cleaning brush can be automatically cleaned without frequent cleaning.

 

Maintenance taskRecommended maintenance frequency
Calibrate the sensor (if required by the competent authority)According to the maintenance schedule required by the competent authority

2. Maintenance method Sensor maintenance

  • External surface of the sensor: Clean the external surface of the sensor with tap water. If debris remains, wipe it with a moist soft cloth. For some stubborn dirt, you can add some household washing solution to the tap water to clean it.
  • Check the cable of the sensor: the cable should not be tightened during normal work, otherwise the internal wires of the cable will be easily broken and the sensor will not work properly.

3) Check whether the measurement window of the sensor is dirty and whether the cleaning brush is normal.

  • Check the sensor's cleaning brush for damage.
  • 18 months of continuous use, need to return to the factory to replace the dynamic sealing device.

 

Frequently Asked Questions

 

ErrorPossible reasonsolution

The operation interface cannot be connected or the measurement result is not

displayed.

Controller and cable

connection error

Reconnect controller and

cable

 

Cable failure

Please contact us

The measured value is too high, too low or the value is

continuously unstable

The sensor window is

attached by a foreign object

Cleaning the sensor window

surface

Damaged sensor spongeReplace the sensor sponge

 

Cable Definition

Power information

The power supply must be DC 5-12V +/-5%, current <50mA

Cable information

4 wire AWG-24 or AWG-26 shielding wire. OD=5mm

 

1, red line - power supply (VCC)

2, white line - 485 data _B (485_B) 3, green line --- 485 data _A (485_A) 4, black line --- ground (GND)

5, bare line shielding layer

 
About Us

Xi'an Desun Uniwill Electronic Technology Co., Ltd (Hereinafter referred to as Disen Sensing Company) is located in Xi'an High-tech Development Zone. It is a high-tech company integrating production, R&D, sales and engineering services. Relying on Xi'an's rich high-tech resources, we have carried out technical cooperation with many universities and scientific research institutions, constantly breaking through technical barriers, improving product performance, and using leading technology to provide high-quality products for the water quality monitoring industry.

We launched a wireless water quality monitoring solution based on the current rapid development of the Internet of Things technology, combining smart terminals and traditional display units through wireless transmission to achieve real-time dynamic water quality monitoring functions such as data cloud display, remote cloud control, and upper and lower limit alarms.

 

Hot Products

Real Time Monitoring RS485 Modbus DS206 Blue-Green Algae Sensor In Water Treatment Introduction The ...
DS206 Industrial Online Self Cleaning RS485 Blue Green Algae Sensor for Water Quality Treatment ...
DS206Fluorescent blue-green algae sensor for water quality monitoring in rivers and lakes RS485, ...
DS206 Fluorescence blue-green algae sensor for water quality monitoring of drinking water sources in ...
DS206 High-precision self-cleaning blue-green algae sensor has long service life and long maintenanc...
The digital blue-green algae sensor can be directly connected to water quality monitoring systems ...