Product Details

Industrial grade RS485 NO3-Nitrate sensor electrodes can be replaced for long term online water quality monitoring

Overview

Online nitrate sensor requires no reagents, is environmentally
friendly and pollution-free, and can be monitored online in real time.
Integrate nitrate ion, sodium ion (optional), and reference electrode,
automatically compensate temperature in the water. It can
be directly put into installation, which is more economical, environmentally
friendly, convenient and quicker than traditional nitrate analyzers. The
sensor has excellent reliability, adopts RS485 output, supports Modbus,
and is easy to integrate.

Features

Digital sensor, RS-485 output, support MODBUS
More economical and environmentally friendly, can be monitored online in real time
Automatically compensate temperature in water
High precision and high stability.

 

 

ItemParameters
ModelDSN260
Ammonia Nitrogen Range0~1000mg/l
Ammonia Nitrogen Precision3%
Ammonia Nitrogen Resolution0.1mg/l
Nitrate Range0~50mg/L
Nitrate Precision5%
Nitrate Resolution0.1mg/l
pH range1~12
pH Accuracy±0.1
pH Resolution0.01
Deepest depthUnderwater 10m
Protection levelIP68
Temperature range0~50
Sensor interfaceSupport RS-485, MODBUS protocol
assemblyInput type
Power informationDC 5~12V, current <50mA
Probe cable length10 meters (default), can be customized
Housing materialPOM

 

Precautions

The probe contains sensitive optical and electronic components. Ensure that the probe is not subject to severe mechanical impact. Damage to the sensor due to impact or manpower will not be covered by the warranty. Water ingress to the sensor due to replacement of the pH electrode is not covered by the warranty.

 

Maintenance schedule and method

Maintenance schedule

It is recommended to periodically calibrate or clean the sensor surface according to the actual application scenario.

Maintenance tasks,Recommended maintenance frequency
Calibrate the sensor (if required by the competent authority)According to the maintenance schedule required by the competent authority

 

Maintenance method

Sensor maintenance

1) External surface of the sensor: Wash the external surface of the sensor with tap water. If debris remains, wipe it with a moist soft cloth.

2) Check the cable of the sensor: The cable should not be tight during normal work, otherwise the internal wires of the cable will be easily broken and the sensor will not work properly.

3) Sensor storage: When the sensor is not in use, you should fasten the black plastic cap and check whether the sponge inside is wet. If it is not wet enough, please add 3mol / L potassium chloride solution and let the electrode be stored in the solution with potassium chloride.


 

Quality assurance

Our company assures its first-hand buyers that there will not be any product defects caused by substandard materials or factory manufacturing in the 3 months after shipment.

If a defect is found within the 3-month warranty period, Desun Uniwilli Electronics promises to repair or replace the defective product or return the payment in addition to the first shipping and related formalities. Any product repaired or replaced during the warranty period will only enjoy the remaining warranty period of the original product.

This warranty does not apply to consumables such as consumable parts (including but not limited to lamps, pipes, etc.).

Contact Desun Uniwill Electronics or your agent to begin technical support during the warranty period.

After receiving the customer's questions about product quality, our company will confirm whether the product needs to be repaired within two weeks; products that have not been approved for repair cannot be returned.

Hot Products

Ion selective electrode nitrate sensor for aquaculture with pH compensation and temperature ...
Reagent-free ion selective electrode nitrate sensor with automatic temperature and pH compensation, ...
Industrial grade RS485 NO3-Nitrate sensor electrodes can be replaced for long term online water ...
IP68 rated nitrate sensor for wastewater treatment and river monitoring with a customizable range of ...
Nitrate sensor with integrated nitrate ion, sodium ion (optional) and reference electrode, ...
High accuracy nitrate sensor for water quality monitoring in aquaculture wastewater plants 0-200mg/L ...