Beer Brewing Industrial Dissolved Oxygen Sensor Environment Monitoring 3 sec Response

Country/Region china
City & Province Shaanxi
Categories Water Treatment
InquireNow

Product Details

China Competitive Price Beer Brewing Industrial DO Sensor Water Dissolved Oxygen Sensor environment monitoring modbus

 

Dissolved oxygen sensor based on the latest polarographic analysis technology, using breathable film, film head for integrated production, easy maintenance and replacement. It is suitable for wastewater, sewage treatment, aquaculture and other fields.

 

The housing material is manufactured from 316L stainless steel, which is corrosion resistant and more durable. The seawater type can also be titanium material, which also performs well under strong corrosion.

 

Technical Parameters of Dissolved Oxygen Sensor

 

ItemParameters
ModelDS380
PrincipleFluorescence analysis method
Measuring range0~20mg/L or 0-200% saturation
Response time3 sec
Accuracy1%
Protection levelIP68
InstallationSubmersible
Temperature sensorNTC
Temperature range0~50°C
Temperature accuracy±0.2°C
OutputSupport RS-485, MODBUS protocol
Power supplyDC 6~12V, current <50mA
SizeΦ26*155 mm
Probe cable lengthDefault 5 m, customized 10m, 15 m and 30 m cable
Fluorescent cap life1 year
Maximum working pressure6bar
product materialPOM/SS316/Titanium alloy
Calibration methodOne or Two-point calibration
Power consumption< 0.5 W

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fluor Cap Inner Surface


If water vapor or dust intrudes into the inside of the fluorescent cap, the cleaning steps are as follows:

  • a. Remove the fluorescent cap
  • b. Flush the inner surface of the fluorescent cap with tap water
  • c. For fats containing fat and oil, wash with warm water with household washing solution
  • d. Flush the inner surface of the fluorescent cap with deionized water
  • e. Gently dry all surfaces with a clean lint-free cloth and place in a dry place to allow the water to completely
  • f. evaporate.

 

   

 

Hot Products

Aquarium Digital Dissolved Oxygen Probe for Sale measurement principle fluorescence analysis ...
China Competitive Price Beer Brewing Industrial DO Sensor Water Dissolved Oxygen Sensor environment ...
Fluorescence Analysis Dissolved Oxygen Sensor Probe 12V Titanium Features * 0-20mg/L or 0-200% ...
Introduction Dissolved oxygen sensor based on the latest polarographic analysis technology, the ...
Online Fluorescence Dissolved Oxygen Sensor High Accuracy dissolved oxygen sensor Brief introduction ...
Universal Dissolved Oxygen Meter orp measurement in drinking water DO Temperature Product Descriptio...