Home Companies Xi'an Desun Uniwill Electronic Technology Co., Ltd.

Hydrocarbons Monitoring In Water-PAH Analyzer Fluorescence Method

Xi'an Desun Uniwill Electronic Technology Co., Ltd.

Contact Us

[China] country

Trade Verify

Address: Room 502, Unit 2, Building 1, Yi Cui yuan i city, No. 11, Tangyan South Road, Yanta District, Xi'an city, Shaanxi Province, China.

Contact name:Wang

Inquir Now

Xi'an Desun Uniwill Electronic Technology Co., Ltd.

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

Hydrocarbons Monitoring In Water-PAH Analyzer Fluorescence Method

Country/Region china
City & Province Shaanxi
Categories Instrument Parts & Accessories
InquireNow

Product Details

Hydrocarbons Monitoring in Water-PAH Analyzer

A PAH sensor, which stands for Polycyclic Aromatic Hydrocarbon sensor, is a device used to detect the presence and concentration of polycyclic aromatic hydrocarbons in a given environment. Polycyclic aromatic hydrocarbons (PAHs) are organic compounds composed of multiple fused aromatic rings, and they are often found as pollutants in the environment due to incomplete combustion of organic materials such as coal, oil, gas, and wood. PAH sensors typically utilize various detection techniques such as spectroscopy, chromatography, or electrochemical methods to quantify PAH levels. These sensors are important tools in environmental monitoring, particularly in assessing air and water quality, as PAHs are known to be carcinogenic and can have harmful effects on both human health and the environment.


Product Introduction

Desun Uniwill PAH Measurement Sensors, designed for detecting Polycyclic Aromatic Hydrocarbons, is a cutting-edge device revolutionizing environmental monitoring. PAHs are organic pollutants with diverse sources, emphasizing the critical need for real-time monitoring to control pollution and assess associated risks effectively.

 

Desun Uniwill Online PAHs (Polycyclic Aromatic Hydrocarbons) Sensor works in the measuring principle of UV fluorescence, it’s more sensitive and specific than the conventional infrared scattering or absorption methods. This makes it possible to determine the smallest traces of PAHs, e.g. in drinking water, but also in cooling water condensates. It has an RS-485 interface that allows easy and fast sensor configuration via Modbus.

 

 
PAH Monitoring Sensors
 

Features:

 

-PAH Measurement Range: 0 – 1000 ppb (µg/L)
-Equipped with an RS-485 interface that enables simple and quick sensor configuration via Modbus
-In situ measurement, no sampling no reagents
-Installations on the inlet and outlet of the scrubber
-Fluorescence probe for PAH/Oil in water measurements
-Corrosion-free Housing
-Detects oil in water through UV fluorescence
-Real-time in-line measurement
-Simple installation and operation

 

PAH Testing Purpose
1. Trace oil in water
2. Leak detection
3. Oil Spill Monitoring
4. Water Quality Monitoring
5. Hydrocarbons monitoring in water
6. Oil in Water Monitoring

 

PAH Monitoring Medium
1. Ballast Water
2. Discharge Water
3. Industrial Wastewater
4. Drinking Water
5. Washing Water
6. Cooling water & condensate return
7. Process water (refineries, desalination plants)
8. Rainwater (airport runoff monitoring)


 

Technical parameters
 
Product Name
PAH SensorPAHs Analyzer
PrincipleFluorescence MethodFluorescence Method
Range
 
0~300ppb
0~500 ppb
0~1000 ppb
( Can be customized)
0~50 ppb
0~100 ppb
0~1000 ppb
( Can be customized)
Detection Limit5ppb0.5ppb
Accuracy
±5%FS±3%FS
Response time<10s<10s
Minimum test intervals5s5s
Interface
RS-485, Modbus RTURS-485, Modbus RTU
Power supply12-24VDC12-24VDC
Power consumption1.5W1.5W
Size(L*W*H)
Dimensions (L x Ø)
Φ160mm*38mm142mm*96mm*45mm
Weight900g720g
Protection LevelIp68Ip68
Storage temperature-20-80℃-20-80℃
working temperature0~ 50°C0~ 50°C
Inflow velocity
0.1-10 m/s

0.1-10 m/s

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

There are two measurement modes to choose from:

 

1. Analyzer mode,

Combine the instrument with a flow-through tank to lead the liquid into the glass tube for measurement.

 

2. Probe mode,

Online measurement of PAH (oil) content in water by UV fluorescence method with fast response and high sensitivity.

No need for sampling and sample preparation, no reagents.

Can be connected to supporting instrumentation, and can achieve 4-20mA analog output, to achieve a variety of control methods.

 

The field of application ranges from petrochemistry, and leakage detection in cooling and wastewater streams to environmental monitoring.

 

Desun Uniwill specializes in the design, development, and manufacture of a range of water quality monitoring sensors and controllers. PAH sensors are our latest sensors and are mainly used in marine exhaust gas cleaning systems.

 

Our main products include dissolved oxygen sensor, PH sensor, ORP sensor, turbidity sensor, conductivity sensor, COD sensor, ammonia nitrogen sensor, sludge concentration sensor, chlorophyll sensor, blue-green algae sensor, oil in water sensor, PAH Sensor, nitrate sensor, multi-parameter water quality sensor, etc. With an experienced and professional team, we have exported our products to more than 30 countries and regions worldwide, especially in South America and Southeast Asia.

 

Hot Products

PAH Monitoring Sensors For Online Monitoring Of Hydrocarbon In Water Product Introduction Desun ...
PAH Measurement Sensor for Online Hydrocarbon Monitoring Desun Uniwill is delighted to introduce its ...
PAH Sensor for Detecting Petroleum Products-Hydrocarbon Detectors Fluorescence measurement is ...
Hydrocarbons Monitoring in Water-PAH Analyzer A PAH sensor, which stands for Polycyclic Aromatic ...
Hydrocarbon Sensor for Exhaust Gas Wash Water Monitoring The measuring principle is based on the ...