Home Companies Shanghai S&D International Dental Co., Ltd.

Dental Root Canal Rotary Files Reamer Instruments Size 15-60 F Gold Both Taper 4 Taper 6

Shanghai S&D International Dental Co., Ltd.

Contact Us

[China] country

Trade Verify

Contact name:Alex Shi

Inquir Now

Shanghai S&D International Dental Co., Ltd.

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

Dental Root Canal Rotary Files Reamer Instruments Size 15-60 F Gold Both Taper 4 Taper 6

Country/Region china
InquireNow

Product Details

Dental Endo Files System Size 15-60 F GOld For Root Canal Treatment Rotary Use With Both Taper 4 And Taper 6

 

S&D F Blue

This is the dental file For cleaning and shaping root canal.It is non-sterile instrument .

2.Main materials

1) Cutting Nickel Titanium (including nickel and chromium) -blue and gold

2) Shank: copper

 

Purpose of use and effect -efficacy

This instrument is for For the removal of dentin and shaping of the root canal.

 

Specifications

Under the provisions of ISO 13485 performance test, product durability for twisting and bending must exceed specified value of our standard.

#15

04/06#2004/06
#2504/06#3004/06
#3504/06#4004/06
#4504/06#6004/06

 

Method of manipulating or method of use

The crown down technique is the technique of choice for rotary instruments.

Rotary:300-350rpm,Torque:2-3

 

Precautions for use

1.To prevent infection, sterilize the product by autoclave and make sure sterilization is completed before using .

2. Choose the most appropriative type for each case and follow the general method.

3.Before using, make sure the instruments outside of oral cavity that there are no deformations, scratches and cracks .

4. If the head of product is thin, long or large, there are possibilities for breaking or twisting. Because of this, be sure to avoid using unreasonable angle and excessive pressure.

5.Wear safety glasses to protect your eyes from damage. Also, wear a dust protective mask to prevent inhaling dust .

6.A chain, string, or other instrument shall be attached to the hole through the shank to prevent it from falling into the mouth.

7. A rubber dam or gauze screen should be used to prevent accidental ingestion and aspiration. Patients with a high likelihood of accidental ingestion or aspiration should not be treated in a horizontal position and should be treated in a seated position whenever possible.

8. Do not use this instrument for any purposes except for listed applications above.

9.Only for use by dentists.

10.This product should be treated as medical waste when disposed.

11.Dispose the product if damaged or contaminated .

12.After using, wash it with medical cleaning agent and brush, then wash away foreign substances like adherent body fluids and body tissues.

13.Avoid using unreasonable angle and excessive pressure.

14. This product has possibility that be corrosive if sunk into NaOCl, EDTA and etc . for a long time.

 

Storages and duration of use

1. Avoid storing at high temperature, humidity and direct sunlight.

Keep liquids away. Store it at room temperature.

2. Do not damage or make a pinhole to packaging materials.

3. The product is subject to be improved without previous notice. Enforce

the first-in first-out method for stock management.

4. Do not store the product under a germicidal lamp to avoid deterioration.

 

Maintenances and inspections

Sterilize this product by autoclave under established method and term for each use.

Method of sterilization:

Put this product in a sterilization pack (or foil) and place it on a sterilization tray, or files stand for autoclave sterilization with reference to the following terms.

Terms for sterilization:

term(1) temperature: 134degrees Celsius time: 15 minutes or more

2.Do not use high pressure steam sterilizer which heats more than 200 degrees Celsius including drying process .

3. When reusing the instrument, wash away foreign substances completely and sterilize.

4.Regarding use of medical cleaning agent, follow the instruction manual by its manufacturer strictly.

5.Dispose the products if damaged or decreased performance.

 

Instruction of using 

Initiate Crown Down cleaning and shaping technique

•In small canals (mesials/buccals of molars, small premolars and lower anteriors)start with a 30/.04 rotary file. Take 30/.04 to resistance or working length .If resistance is encountered before working length is obtained, go to next smaller instrument following the same protocol until working length is achieved. Between each rotary file recapitulate with a #10 or #15 tip hand file to maintain glide path and help irrigate (NaOCl) to the canal terminus.

•In larger canals (palatal/distals of molars, larger premolars, upper anteriors) beginwith a 40/.04 rotary file. Use the crown down technique to resistance or working length. If resistance is encountered before working length is achieved, move on to smaller sized instruments until working length is achieved. Between instruments, recapitulate with a small hand instrument to maintain a glide path to working length.

• In the coronal portion of moderate to mild curvatures, you can utilize an .06 taper instrument.

Hot Products

Dental Process With Heat-Treatment Gold Color Rotary Endo Files Pathfile Is Flexible For Searching ...
Dental F blue Endo Files System Size 15-60 For Root Canal Treatment Rotary Use With Both Taper 4 And ...
Dental Endo Files System Size 15-60 F GOld For Root Canal Treatment Rotary Use With Both Taper 4 And ...
Dental Stainless Steel Files Hand Use K-Flex File Endo Files with size #15-40 used for root canal ...
Dental Process With Heat-Treatment Gold Color Rotary Endo Files P Glider File Is Flexible For ...
Dental Root Canal Files Reciproc File Engine Endo File Also Named Single File System With Size 25 40 ...