2800RPM Rotating Anode X Ray Tube Assembly 110kJ Anode Heat Storage Capacity

Country/Region china
City & Province hangzhou zhejiang
InquireNow

Product Details

150kV X‐Ray tube assembly Equivalent To Toshiba E7843/RAD12/RAY-12

 

Technical Data

PropertySpecificationStandard
Nominal input power(s) of the anodeF 1F 2IEC 60613
20kW(50/60Hz)46kW(50/60Hz) 
Anode heat storage capacity110kJ (150kHU)IEC 60613
Maximum cooling capacity of the anode475W 
Heat storage capacity900kJ 

Max. continuous heat dissipation

without Air-circular

180W 

Anode material

Anode top coating material

Rhenium-Tungsten-TZM(RTM)

Rhenium-Tungsten-(RT)

 
Target angle (Ref: reference axis)12°IEC 60788
X-ray tube assembly inherent filtration1.5 mm Al / 75kVIEC 60601-1-3
Focal spot nominal value(s)F1(small focus)F2(large focus)IEC 60336
0.61.2 

X-ray tube nominal voltage

Radiographic

Fluoroscopic

150kV

125kV

IEC 60613

Data on cathode heating

 

Max. current

Max voltage

≈ /AC, < 20 kHz 
F1F 2 

4.7 A

≈6.8~8.6V

5 A

≈12.9~16.5 V

 

Leakage radiation at 150 kV / 3mA in

1m distance

≤ 1.0 mGy/hIEC60601-1-3
Maximum radiation field430×430mm at SID 1m 
X-ray tube assembly weightApprox. 18 kg 

 

Quick Detail:

 

◆ X-ray tube assembly for all routine diagnostic examinations with conventional or digital radiographic and fluoroscopic workstations

◆ The insert features: 12° Rhenium-Tungsten molybdenum target (RTM)
◆ Focal spots: Small 0.6, Large: 1.2
◆ Maximum tube voltage: 150kV
◆ Accommodated with IEC60526 type high-voltage cable receptacles
◆ High voltage generator should accord with IEC60601-2-7
◆ IEC Classification (IEC 60601-1:2005): Class I ME EQUIPMENT

◆ Equivalent To: Toshiba E7843/RAD12/RAY-12

 

 

Description

.● The designation is composed as follows:

 

SRMWHX7420TubeAHigh voltage socket with 90 degree direction
SRMWTX74-0.6/1.2-150BHigh voltage socket with 270 degree direction

 

 

Conditions for operation, storage and transport

 

 

LimitsOperation LimitsTransport and Storage Limits
Ambient temperatureFrom 10℃to 40℃From- 20℃to 70℃
Relative humidity≤75%≤93%
Barometric pressureFrom 70kPa to 106kPaFrom 70kPa to 106kPa

 

Stator key values

1-phase stator

 

Test pointC-PC-S
Winding resistance≈18.0…22.0Ω≈45.0…55.0Ω
Max. permissible operating voltage(run-up)230V±10%
Recommend operating voltage(run-up)160V±10%
Braking voltage70VDC
Run-on voltage in exposure80Vrms
Run-on voltage in fluoroscopy20V-40Vrms
Run-up time(depending on starter system)1.2s

 

 

 

 

 

 

 

More Detailed Images

 

 

 

More product:

TypeFocal spotmax.rating(KW)Max voltag(kV)Target angle()Target materialRotation rate(W/min)Max component heat content(KJ)Max anode heat content(KHU)Max anode continuous heat dissipation(W)
SRMWHX64100.3/0.65/17(50Hz)13010RTM2800900210300
SRMWHX64110.6/1.311/32(50Hz)13015RTM2800900110300
SRMWHX64120.8/1.812/33(50Hz)13015RTM280090070175
SRMWHX64600.6/1.311/33(50Hz)13015RTM2800/8400900110300
20/54(150Hz)
SRMWHX70101.0/2.021/42.5(50Hz)12516RTM2800900140475
SRMWHX71100.6/1.220/40(50Hz12512.5RTM2800900150500
SRMWHX72101.0/2.020/40(50Hz)12516TM2800900140410
SRMWHX72201.0/2.020/40(50Hz)15016TM2800900140410
SRMWHX73600.6/1.220/50(50Hz)15012RTM2800/8400900300750
30/74(150Hz)
SRMWHX74200.6/1.220/46(50Hz)15012RTM2800900150475
SRMWHX75200.6/1.220/50(50Hz)15012RTM2800900220750
SRMWHX76200.6/1.220/50(50Hz)15012RTM2800900300870
SRMWHX78100.6/1.518/47.5(50Hz)12514RTM2800900200410
SRMWHX90200.6/1.219/50(50Hz)15012RTM28001100300500
SRMWHX91201.0/2.030/50(50Hz)15016RTM28001100200490

Hot Products

90º Plug 75KV HV Generator Accessories X-ray High Voltage Cables SRX-Z75-T Description: This 3...
Rotating Anode X‐Ray tube assembly for medical x ray machine Description .● The designation is ...
150kV X‐Ray tube assembly Equivalent To Toshiba E7843/RAD12/RAY-12 Technical Data Property ...
150kV Rotating Anode X‐Ray tube assembly Equivalent To Toshiba E7843/RAD12/RAY-12 for DR or CR ...
150kV X‐Ray tube assembly Equivalent To Toshiba E7252/RAD14/RAY-14 Conditions for operation, storage ...
125kV Rotating anode X‐Ray tube assembly for CR or DR machine Equivalent To: Toshiba E7239 Stator ...