Dissolved Air Flotation Description
Dagyee DAF System proactively promotes solid/liquid separation providing better contaminant removal, more efficient chem usage and drier sludge – using a much smaller footprint than conventional DAFs.However, as opposed to DAF's that require significant retention time and rely on the old-school particle collision process to float solids, the DAF System injects air into 100% of the waste stream while pushing water through a series of hydrocyclones under controlled pressure, removing up to 100% of TSS & FOG. Chemicals are uncoiled in the Heads availing more than 2x the charge sites resulting in a higher rate of contaminant removal. Since separation occurs in the Heads, large tight flocs float and are skimmed off the tank into a sludge hopper. Drier sludge ensues as the air dissipates and chemicals recoil, to naturally dewater the flocs. Costs are reduced due to lower chemical, sludge handling and building costs.
Dissolved Air Flotation Feature
Small footprint, Low energy consumption;
Easy operation;
Simple management;
Efficient dissolved air;
Stable treatment effect ;
Full-automatic operation;
Dissolved Air Systerm is used in this device. It has ingenious
structure, and its efficiency of dissolving air is as high as
90%; But its volume is only one-fifth of the other kind of
dissolved air system. In addition, it still has the super
anti-clogging ability which is incomparable;
Release effect and the mean diameter of microbubble is only between 15 to 30 microns. In addition that,this kind of dissolved air releasers also has the self-cleaning ability;
This device also applies Chained Scum Skimmer, works Smooth and reliably and skims scum efficiently.
Dissolved Air Flotation Available Options
Access platforms with ladder or stairs
Automatic sludge pump out packages
Chemical pretreatment systems
Concrete tank designs for large in ground installations
Duplex systems for redundancy
Effluent monitoring
Effluent sampling
Explosion-proof design
Flash mix/flocculation tanks with mixers
Full FRP or stainless steel construction
Influent equalization
Influent / effluent lift stations
Instrumentation and controls
Removable covers with gaskets
Integral mechanical sludge thickener
On board reagent storage (day tanks)
Pilot size units for on-site testing
Potable water design
Special coatings
Sludge handling and dewatering
30m3/hr Dissolved Air Flotation Specification
Parameter | Units | DAF-030 |
DAF Flow Rate | m3/hr | 30 |
Total Inlet Solids | mg/L | 500-6500 |
FOG Removal | % | 80~97 (Application Dependent) |
TSS Removal | % | 60~99 (Application Dependent) |
COD Removal | % | 20~80 (Application Dependent) |
BOD Removal | % | 20~80 (Application Dependent) |
Power Consumption | kW | 4.7 |
Footprint | m | 6.8*3.2 |
Inlet | in | 6 |
outlet | in | 6 |
Sludge outlet | in | 6 |
Vent | in | 4 |
STANDARD INCLUSIONS + OPTIONS | ||
Skimmer Mounted Plant | ✓ | |
Feed Pump | ✓ | |
Micro bubble generator |
| ✓ |
Recycle clean water system |
| ✓ |
Maintenance platform, ladder |
| ✓ |
Pre-Treatment | o | |
Control System | ✓ | |
Control System with PLC | o | |
Air Compressor | ✓ | |
Treated Water Recycling for Saturator | o | |
Coagulation, flocculation reaction device | o | |
Chemical powder dissolving dosing device | o |
Dissolved Air Flotation Applications
Meat, poultry, and fish processing
Dairy industry
Petrochemicals
Pulp and paper
Food and beverage