GDVA-404 Automatic Current Transformer CT Analyzer


I. Application

Tests for Current Transformer:

  • Excitation curve and parameters test
  • Turns ratio test
  • Ratio and phase error test
  • Polarity mark check
  • Coil resistance measurement
  • Secondary loop burden measurement
  • Error line curve test for protection CT
  • Transient CT parameters test
  • CT nameplate guess
  • Saturation hysteresis loop curve measurement

Tests for Voltage Transformer:

  • Turns ratio test and phase angle error test
  • Polarity test
  • Secondary burden test
  • Coil resistance test

Applications for CT PT Tester:

  • CT nameplate check
  • CT parameters check in work burden
  • CT transient parameters analysis
  • CT ratio and phase error calibration
  • PT routine test
II. CT PT Tester Technical Index
1 Test standards: IEC60044-1, IEC60044-6, GB1208, GB16847, C57.13
2 Power supply: AC220V±10%,50Hz/60Hz±10%
3 Power output: 0.1~180V (AC)
4 Current output: 0.001~5A(RMS)
5 Power output:300VA
6 Maximum knee voltage measurement:45kv
7 Current measurement:
Range:0~10A (automatically change range in 0.1/0.4/2/10A)
Error <±0.1%+0.01%FS
8 Voltage measurement:
Range:0~200 V (automatically change range in 1V/10V/70V/200V)
Error < ±0.1%+0.01%FS
9 Turns ratio measurement:
Range : 1~35000,
1~2000 error<0.05%
2000~5000 error>0.1%
5000~35000 error<0.2%
10 Phase measurement: error:±2min,resolution:0.01min
11 Coil resistance measurement:
Range:0~8kΩ (automatically change range in 2ohm/20ohm/80ohm/800ohm/8kohm)
Error< 0.2%RDG+0.02%FS
Maximum resolution:0.1mΩ
12 Temperature measurement:-50~100 Celsius degree, error<3 Celsius degree
13 CT Secondary burden:
Range 0~160ohm (automatically change range in 2ohm/20ohm/80ohm/160ohm)
Error <0.2%RDG+0.02%FS
Maximum resolution 0.001ohm
14 PT Secondary burden:
Range 0~80kohm (automatically change range in 800ohm/8kohm/80kohm)
Error <0.2%RDG+0.02%FS
Maximum resolution: 0.1ohm
15 PT ratio measurement:
Range :1~35000,
1~5000 error<0.2%
5000~35000 error<0.5%
16 Saved data groups:>1000groups
17 Work condition: Temperature:-10℃~50℃, moist:≤90%
18 Size: 485mm×356mm×183mm
19 Weight: <15Kg
III. Full Set of CT PT Tester

Name

Quantity

Description

Host

1

3M mask cable

2

10M mask cable

1

Grounding cable 6M

1

Diameter size large than4MM

Big test pliers

2

One red and one black

Test gasket

4

Two red and two black

Test pin

4

Two red and two black

Test pliers

4

Two red and two black

Power cable

1

Accessories bag

1

Production disk

1

Include Analysis application and instruction manual

Instruction manual

1

Inspection report

1

Pass certificate

1







































Hot Products

GDVA-405 Multifunctional Turn Ratio CT PT Transformer Testing Equipment Application Tests for ...
GDVA-405 Multifunction CT PT Transformer Tester Application Tests for current transformer Tests for ...
GDVA-405 Advanced Automatic Current Transformer CT and Voltage Transformer PT Tester 1.1 Application ...
GDVA-404 Automatic Current Transformer Tester I.Application Tests for current transformer: 1...
GDVA-404 Automatic Current Transformer CT Analyzer I. Application Tests for Current Transformer: ...
GDVA-404 Portable Current and Potential Transformer CT PT Tester I. Application Tests for Current ...