Home Companies Shenzhen Coolmay Technology Co., Ltd.

Coolmay Industrial HMI Touch Panel 10 Inch HMI Display LED 65536 True Colors 1024*600

Shenzhen Coolmay Technology Co., Ltd.

Contact Us

[China] country

Trade Verify

Address: #526, Block E, Building 5, Software Industry Base, Nanshan District, Shenzhen , China, 518061

Contact name:Sandra

Inquir Now

Shenzhen Coolmay Technology Co., Ltd.

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

Coolmay Industrial HMI Touch Panel 10 Inch HMI Display LED 65536 True Colors 1024*600

Country/Region china
City & Province shenzhen
InquireNow

Product Details

Coolmay Industrial Hmi Touch Panel 10 Inch Hmi Display Led 65536 True Colors 1024*600

 

Human-Machine Interface (HMI) connects industrial control equipment such as programmable logic controllers (PLC), frequency converters, DC speed regulators, and meters. It is a digital device that uses the display screen to write working parameters or input operating commands through an input unit (such as a touchpad, a mouse, etc.) to realize information interaction between humans and machines. It consists of two parts: hardware and software.

 

Product Information of HMI Touch Screen

Operating systemWINCE 7.0
InterfaceUSB portUSB 2.0×1 (USB port and can be connected to external USB flash drive, mouse, etc.)
Download portYes (Type B male port cable for program download)
Ethernet portOptional
COM port1 RS232 and 1 RS485
ProtocolSupport MODBUS, free port and common PLC communication Protocol
OtherAudioOptional
CalendarYes
Input VoltageDefault as DC12~24±10%V
Consumption280mA*24V
Protection ClassIP65 (front panel)
TemperatureAmbient environment: 0~50℃ | Storage environment: -20~70℃
Humidity20%~90% RH
CertificationCE
SoftwareCoolMay HMI programming software
 

 

Product features

  1. Support all fonts WINDOws provided.
  2. 60,000 TFT true color display.
  3. Hseries support vertical display.
  4. Support Ethernet port and audio.
  5. Default Rs232/Rs485 port,support multiple protocols.
  6. Support 18 languages.
  7. Support data storage functions and default as usb flash drive storage,and SD card storage is optional (cannot coexist with usb storage), max.100,0000 data.

 

Our services

Coolmay develops and manufactures HMI, PLC, HMI+PLC all-in-one, modules with Coolmay own brand. We offer services anytime when you need help.

 

Ø Professional R & D team, providespre-sales and after-sales support.Obtained National Patent Certification.

Ø Supports unlimited services viaemail, video, etc.. HMI and PLCsoftware are free of charge.

Ø Product special encryption. Setpassword as 12345678 to protectprgramming. Supports programmingwith MOQ 200 sets.

 

 

Shipping

 

By courier, door to door

For samples, the package will be delivered by DHL/UPS/FedEx/EMS express. Usually it will take 3-7 days to your location.

Post service

If you are not hurry but need economical delivery, we can go with packet channel. The delivery time depends on your location.

Air shipping or by sea

If bulk order, the packages will be delivered by air shipping or by ship.

 

 

FAQ

1.Precautions of using PLC transistor and relay
The PLC output is a common cathode output, the theoretical value is 1A, the actual use is less than 500mA, the COM wiring is negative, please use 24V voltage, there is no voltage output when it is used as a switch. If an external relay, the relay needs an external power supply.
The relay has a contact life, the theoretical value is 30W times, and the theoretical value of the external load does not exceed 5A. Frequently, the full load current may affect the service life, and there is no voltage out.
2.Precautions of Coolmay PLC output type selection
MT: indicates the transistor output, MR: indicates the relay output, and MRT: indicates the relay transistor mixed output.
The main differences between transistor output and relay output are:
(1)The difference in current load. At present, we use a transistor with a maximum current load of 500MA, and the maximum current load of the relay is 5A (the maximum relay current of the EX2N(S)/DX2N(S) series PLC is 3A);
(2)Output power: The transistor can only be connected to the DC24V power supply , and the relay can be connected to the DC24V and AC220V power supply ;
(3)Functional characteristics: If you need to send a pulse to drive a stepper motor, you should use the transistor output or the mixed output. Also if the output switch is active, it is recommended to use a transistor output;
(4)If both the relay and the transistor are available, it is recommended to use a transistor output because the transistor has no contact life limit and the lifetime will be longer than the relay as long as the current does not exceed the limit.

 

 

 

 

Hot Products

Coolmay 10 Inch HMI Lcd Touch Screen Panel LED 1024*600 Piexls Support Modbus Product Description ...
Coolmay 10 Inch HMI Human Machine Interface LED Support Modbus RS232 RS485 Product Description Model ...
Coolmay 10 Inch HMI Human Machine Interface Touch Screen Panel Lcd Support Modbus Product Descriptio...
MT Series 10 Inch Indusrial HMI Touch Screen Panel Led Support Modbus RS232 RS485 Product Descriptio...
Coolmay Industrial Hmi Touch Panel 10 Inch Hmi Display Led 65536 True Colors 1024*600 Human-Machine ...
5 Inch Hmi 65536 True Colors Touch Screen Led Backlight 1 RS232 RS485 800*480 Resolution Human...