Home Companies WENZHOU SANTUO ELECTRICAL CO.,LTD.

2Pole 4 Pole differential current Earth Leakage Circuit Breaker Fixed Type 440V rated voltage outdoor circuit breaker

WENZHOU SANTUO ELECTRICAL CO.,LTD.
Active Member

Contact Us

[China] country

Address: No. 3999 LiuJiang Road, Liushi, Yueqing, Wenzhou, Zhejiang, China

Contact name:Sunny Zhang

Inquir Now

WENZHOU SANTUO ELECTRICAL CO.,LTD.

2Pole 4 Pole differential current Earth Leakage Circuit Breaker Fixed Type 440V rated voltage outdoor circuit breaker

Country/Region china
City & Province wenzhou zhejiang
Categories Battery Chargers
InquireNow

Product Details

STG(Pg)Series 2Pole 4 Pole differential current Earth Leakage Circuit Breaker Fixed Type 440V rated voltage outdoor circuit breaker

 

GENERAL


An Earth-leakage circuit breaker (ELCB) is a safety device used in electrical installations with high Earth impedance to prevent shock. It detects small stray voltages on the metal enclosures of electrical equipment, and interrupts the circuit if a dangerous voltage is detected. Once widely used, more recent installations instead use Residual Current Circuit Breakers which instead detect leakage current directly.

 

Specification:

 

TypeSTG230STG420
Rated Current(A)10A,15A,20A,25A,32A,40A,50A,60A10A,15A,20A,25A,32A,40A,50A,60A
Pole Number2Pole4Pole
Leakage acting current(mA)300mA,500mA300mA ,500mA
Range of break-off0.5~1.0X IΔn0.5~1.0X IΔn
Rated Voltage(V)220V-250VAC240V/415VAC
Tripping time100ms100mS
Life100000 times100000 times
Ambient Temperature-5°C ~ +55 °C-5°C ~ +55 °C

 

Voltage-operated (ELCB)

 

Voltage ELCBs have been in widespread use since then, and many are still in operation but are no longer installed in new construction. A voltage-operated ELCB detects a rise in potential between the protected interconnected metalwork (equipment frames, conduits, enclosures) and a distant isolated Earth reference electrode. They operate at a detected potential of around 50 volts to open a main breaker and isolate the supply from the protected premises.

 

A voltage-operated ELCB has a second terminal for connecting to the remote reference Earth connection.

 

The Earth circuit is modified when an ELCB is used; the connection to the Earth rod is passed through the ELCB by connecting to its two Earth terminals. One terminal goes to the installation Earth CPC (circuit protective conductor, aka Earth wire), and the other to the Earth rod (or sometimes other type of Earth connection).

Hot Products

STMC IEC Standard 100 Amp 3 Phase Contactor 660V 50/60HZ Silver Texture GENERAL STMC Series AC ...
SC1-N Industrial White AC Contactor With A 24 Volt Coil 50/60Hz CE Credential GENERAL SC1-N Series ...
ST1(LC1-D) Series Industrial Black color AC Contactor LC1-D With A 24 Volt Coil 50 / 60Hz CE ...
STH8 series Household Contactor 1P,2P,3P,4P up 16,25,32,40,63,100A 18mm width PA66 plastic cover 85...
ST1 Series AC Contactor is suitable for using in the circuits the rated voltage up to 660V AC 50Hz ...
SONTUOEC SC2 series Big current LC1F/ CJX2-F AC Contactor with CE approvals SC2(LC1-F) Model AC ...