Various Durable Using Power Transformer Mobile Compact Substation

Country/Region china
City & Province ningbo zhejiang
Categories Other Roadway Products
InquireNow

Product Details

Promotional Various Durable Using Power Transformer Mobile Compact Substation

 

* Carefully Selected Materials
The shell is made of stainless steel, aluminum alloy, cold-rolled plate, color steel plate, tiled, wooden strip, etc., and has good insulation, sealing and excellent heat resistance.

* With Major Brands
Effective control and protection system, fast installation and operation, superior performance.

* High Quality
The internal wiring is neatly arranged, the loss is low, and the heat dissipation performance is strong, which can be used in different environments.

* Long Service Life Of Equipment
The use of automated equipment to ensure accurate product size, production and production in strict accordance with international standards, maintenance-free during the period, the quality is more guaranteed.

 

Service condition

1 Ambient condition

a. Altitude ≤ 1000m;

b. Ambient temperature

Range of temperature: -25℃~+40℃;

c. Wind speed (outdoor) ≤ 35m/s;

d. Relative humidity ≤ 90%(+25℃);

e. Installation spot

The place shall have no fire, explosion, chemical corrosion and exquisite vibration.

2 Move condition of the substation

a. Max. speed ≤ 30km/h,when road surface is flat;

b. Max. speed ≤ 10km/h, when road surface is not flat.

Note: If the above condition can’t satisfy requirements, customer can consult with manufacturer to resolve it.

 

 

 

Table1 

No.ItemUnitParameter
1System voltagekV132
2Rated voltagekV145
3Rated frequencyHz50
4Rated currentA2000 ,1600
5Rated 1min power frequency withstand voltagekV275
6Rated lightning impulse withstand voltagekV650
7Rated short time withstand currentKA25,31.5,40
8Rated short time withstand times3
9Rated peak withstand currentkA63,80,100

 

Table 2 Rated technical parameter of circuit breaker 

No.ItemUnitParameter
1System voltagekV132
2Rated voltagekV145
3Rated frequencyHz50
4Rated currentA2000
5Rated 1min power frequency withstand voltagekV275
6Rated lightning impulse withstand voltagekV650
7Rated short time withstand current / timeKA/s40/4
8Rated peak withstand currentkA100
9Rated short circuit breaking currentkA40
10Rated short circuit making currentkA100
11DC component%40
12Rated operation sequence O 0.3s CO 180s CO
13Opening timems35±5
14Closing timems105±15
15Breaking timems≤60
16Non-simultaneity between polesClosingms≤5
Openingms≤3
17Fracture no. of each pole 1
18Mechanical enduranceTimes≥6000
19Full capacity continuous breaking timesTimes≥20
20

SF6 gas pressure

(20℃)

Rated valueMPa0.60
Alarm valueMPa0.55
Locking valueMPa0.50
21

SF6 gas moisture

content(μl/l)

Acceptance valuePPm≤150
Operation allowable valuePPm≤300
22SF6 yearly gas leakage rate%≤0.5
23Total weight of each circuit breakerkg2000

 

Table3 table4 Parameters of current transformer 

Rated primary current150,300,500,750,1000,1500,2000
Rated secondary current5A

Rated output capacity and accuracy level

 

See table 4

 

Current ratioRated output capacity VAMeasure accuracy levelProtection accuracy level

150/5

300/5

500/5

750/5

1000/5

1500/5

2000/5

20

20

30

30,40

40,50

50

50

0.5

0.5

0.5

0.5

0.5

0.5

0.5

5P20

5P20

5P20

5P20

5P20

5P20

5P20

 

Note: (1) Straight-through type bushing current transformer is attached in the circuit breaker.

 

Table5 Parameters of lightning arrester

No.ItemUnitParameter
1System voltagekV132
2Rated voltagekV150
3Rated frequencyHz50
4Nominal discharge currentkA10
5DC 1mA reference voltagekV≥245
6Residual voltage under lightning impulse current (peak)kV≤435
7Residual voltage under operation impulse current (peak)kV≤370
22Residual voltage under steep wave impulse current (peak)kV≤490

 

Table 6  Parameters of neutral point lightning arrester

No.ItemUnitParameter
1System voltagekV132
2Rated voltagekV90
3Rated frequencyHz50
4Nominal discharge currentkA1.5
5DC 1mA reference voltagekV≥140
6Residual voltage under lightning impulse current (peak)kV≤260
7Residual voltage under operation impulse current (peak)kV≤240
8Residual voltage under steep wave impulse current (peak)kV/

 

 

Table7  Technical parameters of switch equipment on LV side

 

No.ItemUnitParameter
1System voltagekV11.5
2Rated voltagekV12
3Rated frequencyHz50
4Rated currentA2000,1600,1250,
5Rated 1min power frequency withstand voltagekV42/48
6Rated lightning impulse withstand voltagekV75/85
7Rated short time withstand currentkA40,31.5,25
8Rated short time withstand times4
9Rated peak withstand currentkA100,80,63
10Rated short circuit breaking currentkA40,31.5,25
11Rated short circuit making currentkA100,80,63
12Rated operation sequence O 0.3s CO 180s CO
13Mechanical enduranceTimes≥10000

Hot Products

132kv Outdoor Distribution Emergency Power Mobile Transformer Substation 132KV Prefabricated Mobile ...
132KV Mobile Transformer Substation / Distribution Movable Power Substation General: Ningbo Tianan ...
Outdoor Compact Transformer Substation 15KV For Ethiopian Electric Utility EEU This substation body ...
Voltage Distribution Compact Package Substation Medium Voltage Switchgear General: Series 110KV ...
Promotional Various Durable Using Power Transformer Mobile Compact Substation * Carefully Selected ...
Compact Substation 11kv Compact Substation Power Transformer Box Electricity Substation ZGS-Z.G-2750...