SGR SGN Flare Solder Sintered Glass Sight Glass Refrigeration System Components

Country/Region china
City & Province shenzhen
Categories Refrigeration & Heat Exchange Parts
InquireNow

Product Details

Flare And Solder Sight Glass For Refrigeration System,Condensing Unit,Refrigeration Unit,Cooling Equipment

 

Description:

Both Model SGN sight glass and Model SGS sight glass are used on the liquid piping of the refrigeration and air conditioning unit to indicate the flow condition of the refrigerant, water cut of the refrigerant and lubricant oil flow condition of the oil return piping on the oil separator.

 

Model SGN sight glass and Model SGS sight glass are equipped with one moisture indicator, which will change color to indicate the water cut in the refrigerant.

 

Model SGR sight glass is used to indicate the level of the refrigerant in the liquid drum and the lubricant oil level in the compressor crankcase.

 

The modified PTFE sealing is used in bothModel SGN sight glass and Model SGR sight glass, which is applicable to various refrigerants and oils with perfect sealing performance. The structure of both Model SGN sight glass and Model SGR sight glass is an explosion-proof press fit and the viewing glass is clear and safety.

 

Model SGS sight glass is an independent body structure with conventional sintered glass and O-ring seal.

 

Specifications

Model of Welded ConnectionSizeModel of Threaded ConnectionSize
SGN-1/4 ODFSGN-1/4 ODF1/4(Φ6)SGS-1/4 SAESGS-1/4 SAE1/4(Φ6)
SGN-3/8 ODFSGN-3/8 ODF3/8(Φ10)SGS-3/8 SAESGS-3/8 SAE3/8(Φ10)
SGN-1/2 ODFSGN-1/2 ODF1/2(Φ12)SGS-1/2 SAESGS-1/2 SAE1/2(Φ12)
SGN-5/8 ODFSGN-5/8 ODF5/8(Φ16)SGS-5/8 SAESGS-5/8 SAE5/8(Φ16)
SGN-3/4 ODFSGN-3/4 ODF3/4(Φ19)SGS-3/4 SAESGS-3/4 SAE3/4(Φ19)
SGN-78 ODFSGN-78 ODF7/8(Φ22)SGR-3/4NPT3/4NPT
——————SGR-G3/4G3/4

 

 

 

Technical Parameters:

Applicable Refrigerant:HCFC and HFC
Applicable Medium Temperature:-40℃~+80℃
Max.Operating Pressure4.5MPa
Max.Allowable Pressure6.8MPa
Yearly Leakage of Refrigerant≤2g R22/a

 

 

Note: For the fully enclosed compressor, generally the allowable water cut is in a range 30~75ppm, but for other types of compressor, the water cut will be higher slightly. For an effective protection, it is necessary to monitor the indicator carefully and replace the drier immediately if the color is changed into yellow.

 

Correlation betwen Water Cut and Color:

 
Water Cut(ppm)
25℃43℃
Green/DRYMedium ColorYellow/WETGreen/DRYMedium ColorYellow/WET
R22/R502<3030~120>120<5050~200>200
HFC-134a<3030~100>100<4545~170>170
R404a<2020~70>70<2525~100>100
R407c<3030~140>140<6060~225>225
R507<1515~60>60<3030~110>110
 

 

 

Should you have any question, feel free to contact. 

 

Hot Products

Air-Cooled Condensers For Refrigeration Units, Condensing Units And Cooling Equipment, Chiller And ...
Heat Pump Coaxial Coils,Water / Ground Source Heat Pump Heat Exchanger For Refrigeration, The ...
EK165 Emerson Liquid Line Filter Drier 5/8" SAE Flare EK series liquid line filter drier with ...
Air Cooled Condenser Condensing Unit Condenser Copeland Refrigeration Unit Condenser​ Features 1. ...
Flare And Solder Sight Glass For Refrigeration System,Condensing Unit,Refrigeration Unit,Cooling ...
083,164,305,415 Eliminator Liquid Line Filter Driers for Refrigeration System Line,Cooling Equipment...